Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Radiol ; 26(3): 900-9, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26162577

ABSTRACT

OBJECTIVES: To compare the diagnostic accuracy of (111)In-pentetreotide-scintigraphy with (68)Ga-DOTATOC-positron emission tomography (PET)/computed tomography (CT) in patients with metastatic-neuroendocrine tumour (NET) scheduled for peptide receptor radionuclide therapy (PRRT). Incremental lesions (ILs) were defined as lesions observed on only one modality. METHODS: Fifty-three metastatic-NET-patients underwent (111)In-pentetreotide-scintigraphy (24 h post-injection; planar+single-photon emission CT (SPECT) abdomen) and whole-body (68)Ga-DOTATOC-PET/CT. SPECT and PET were compared in a lesion-by-lesion and organ-by-organ analysis, determining the total lesions and ILs for both modalities. RESULTS: Significantly more lesions were detected on (68)Ga-DOTATOC-PET/CT versus (111)In-pentetreotide-scintigraphy. More specifically, we observed 1,098 lesions on PET/CT (range: 1-105; median: 15) versus 660 on SPECT (range: 0-73, median: 9) (p<0.0001), with 439 PET-ILs (42/53 patients) and one SPECT-IL (1/53 patients). The sensitivity for PET/CT was 99.9 % (95 % CI, 99.3-100.0), for SPECT 60.0 % (95 % CI, 48.5-70.2). The organ-by-organ analysis showed that the PET-ILs were most frequently visualized in liver and skeleton. CONCLUSION: Ga-DOTATOC-PET/CT is superior for the detection of NET-metastases compared to (111)In-pentetreotide SPECT. KEY POINTS: Somatostatin receptor PET is superior to SPECT in detecting NET metastases. PET is the scintigraphic method for accurate depiction of NET tumour burden. The sensitivity of PET is twofold higher than the sensitivity of SPECT.


Subject(s)
Neuroendocrine Tumors/diagnosis , Positron-Emission Tomography/methods , Tomography, Emission-Computed, Single-Photon/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Bone Neoplasms/diagnosis , Bone Neoplasms/secondary , Female , Gallium Radioisotopes , Humans , Liver Neoplasms/diagnosis , Liver Neoplasms/secondary , Male , Middle Aged , Neuroendocrine Tumors/radiotherapy , Octreotide/analogs & derivatives , Radiopharmaceuticals , Somatostatin/analogs & derivatives
2.
Gut ; 53(1): 21-6, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14684571

ABSTRACT

BACKGROUND: Studies combining pH and Bilitec monitoring found a high prevalence of both acid and duodeno-gastro-oesophageal reflux in severe reflux disease. Clearance of refluxed material is a major defence mechanism against reflux. Several studies have been devoted to oesophageal acid clearance but oesophageal clearance of refluxed duodenal contents (DC) has rarely been addressed. AIM: To compare oesophageal acid and DC clearance. METHODS: Ten healthy volunteers (five women, mean age 23 (1) years) were studied. Firstly, a balloon tip catheter, positioned in the duodenum under fluoroscopy, was used to aspirate DC after stimulation by a high caloric liquid meal (200 ml, 300 kcal). During the second session, pH and Bilitec probes were positioned 5 cm above the lower oesophageal sphincter and a small infusion catheter was introduced into the proximal oesophagus. The subject was placed supine under a gamma camera. One of two different solutions (DC mixed with 0.2 mCi Tc99m pertechnetate or citric acid (pH 2) mixed with 0.2 mCi Tc99m pertechnetate) was infused into the proximal oesophagus and the subject was instructed to swallow at 20 second intervals. Clearance was assessed using scintigraphy (dynamic acquisition, one frame per second in the anterior view; calculation of time to clear peak counts to background level), pH (time to pH<4) or Bilitec (time absorbance >0.14) monitoring, with or without continuous saliva aspiration. Each condition was studied twice in a randomised design; measurement time was four minutes, interrupted by water flushing, with a two minute rest period. Results are given as mean (SEM) and were compared by Student's t test and Pearson correlation. RESULTS: Scintigraphic evaluation showed a volume clearance time of 29 (3) seconds for acid and 28 (9) seconds for DC (NS). Saliva aspiration had no significant influence on volume clearance of acid or DC (28 (4) and 30 (13) seconds, respectively; NS). pH monitoring showed an acid clearance time of 217 (15) seconds, which was significantly prolonged to 324 (30) seconds during saliva aspiration (p<0.05). Bilitec monitoring showed a DC clearance time of 131 (27) seconds, which was not significantly prolonged by saliva aspiration (176 (36) seconds; p = 0.08). DC clearance was faster than acid clearance, either without or with saliva aspiration (p<0.055 and p<0.05, respectively). CONCLUSIONS: Under experimental conditions, liquid acid and DC solutions have comparable volume clearances. Chemical clearance occurs slightly faster for DC than for acid, and saliva plays a major role in the clearance of acid only.


Subject(s)
Bile Acids and Salts/metabolism , Esophagus/metabolism , Gastrointestinal Contents/chemistry , Adult , Esophagus/diagnostic imaging , Esophagus/physiology , Female , Humans , Hydrogen-Ion Concentration , Male , Peristalsis , Radionuclide Imaging , Saliva/physiology , Sodium Pertechnetate Tc 99m , Suction
SELECTION OF CITATIONS
SEARCH DETAIL
...