Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Gastroenterology Res ; 16(2): 92-95, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37187556

ABSTRACT

Background: Abnormal video capsule endoscopy (VCE) findings often require intervention with double balloon enteroscopy (DBE). Accurate VCE reporting is important for procedural planning. In 2017 the American Gastroenterological Association (AGA) published a guideline that included recommended elements for VCE reporting. The aim of this study was to examine adherence to the AGA reporting guidelines for VCE. Methods: The medical records of all patients who underwent DBE at a tertiary academic center between February 1, 2018, and July 1, 2019, were retrospectively reviewed to identify the VCE report that prompted DBE. Data were collected on the presence of each reporting element recommended by the AGA. Differences in reporting between academic and private practices were compared. Results: A total of 129 VCE reports were reviewed (84 private practice and 45 academic practice). Reports consistently included indication, date, endoscopist, findings, diagnosis, and management recommendations. Timing of anatomic landmarks and abnormalities were included in only 87.6% of reports and preparation quality in only 26.2%. Reports from private practice groups were significantly more likely to include the type of capsule (P < 0.001). VCE reports from academic centers were more likely to include adverse outcomes (P < 0.001), pertinent negatives (P = 0.0015), extent of exam (P = 0.009), previous investigations (P = 0.045), medications (P < 0.001), and document communication to patient/referring physician (P = 0.001). Conclusions: Most VCE reports in both private and academic settings included the important elements recommended by the AGA; however only 87% listed the times of landmarks and abnormal findings, which are crucial in determining the type and direction of approach for subsequent interventions. It is unclear whether the quality of VCE reporting influences the outcome of subsequent DBE.

2.
Gastrointest Endosc ; 94(2): 248-259.e2, 2021 08.
Article in English | MEDLINE | ID: mdl-33561486

ABSTRACT

BACKGROUND AND AIMS: The prevalence and burden of ergonomic-related musculoskeletal injury are well established in the literature, but data are scarce on techniques that can be used to avoid injury. This pilot study aimed to develop a new method of endoscopist wellness assessment. The technique presented here is an intervention by a physical therapist assessing ergonomic position and posturing during endoscopy to create an individualized wellness plan. METHODS: Volunteer endoscopists were identified in a single ambulatory surgical center. Demographics, previous injury, current pain, and posture were evaluated. A comprehensive assessment was developed by the physical therapist while observing endoscopists performing at least 2 colonoscopies and while working at their computer workspace. The detailed personalized wellness program included recommendations for individualized exercises, static and dynamic posture re-education during and between procedures, optimization of procedure suite setup, pain education, and an opportunity for follow-up 1-on-1 sessions with the physical therapist. Endoscopists were later interviewed regarding their perception of and compliance with the wellness plan. Specific outcomes evaluated included changes in musculoskeletal pain, acceptance, and incorporation of wellness recommendations and procedure suite alterations into clinical practice. RESULTS: As we developed this new method of endoscopic wellness assessment, 8 endoscopists representing a wide range of ages and clinical experience were assessed. Twenty-two pain sites were identified among 5 subjects, with back and neck pain the most common pain sites. A variety of ergonomic inefficiencies and suboptimal movement patterns was observed, resulting in highly variant wellness plans. By the end of the study, 63% of pain sites were reduced in intensity or resolved, whereas 32% of pain sites were unchanged and 4% increased in intensity. Seven of 8 participants found the pictures depicting their posture that supported their movement analysis helpful, and 3 participants requested reassessment by the physical therapist. All participants reported static and dynamic postural education and procedure suite setup recommendations to be impactful to their ergonomic performance. CONCLUSIONS: Ergonomic assessment and instruction by a physical therapist was well received and resulted in improvement of musculoskeletal complaints among a cohort of endoscopists reporting baseline pain associated with performing endoscopy. In addition, this intervention provided ergonomic education that can be carried forward throughout their professional endoscopic career. We believe that ongoing individualized assessment and optimization of ergonomics is necessary because generalized wellness programs or even modifications to endoscopic equipment would not target all the unique ergonomic challenges faced by each physician. Ergonomic programs using the new method presented here could potentially contribute to career longevity, decrease burnout, reduce lost days of work, and, most importantly, reduce pain and fatigue among practitioners.


Subject(s)
Gastroenterologists , Musculoskeletal Diseases , Occupational Diseases , Ergonomics , Humans , Pilot Projects , Posture
3.
J Clin Gastroenterol ; 55(9): 792-797, 2021 10 01.
Article in English | MEDLINE | ID: mdl-32947375

ABSTRACT

INTRODUCTION: Since 2001, device-assisted enteroscopy (DAE) has revolutionized the diagnostic and therapeutic capabilities for managing small bowel pathology. Though commonly performed, there have been no recent large studies to assess the use, yield, and risks of DAE and none that include all 3 DAE modalities. We hypothesized that DAE is safe with high diagnostic and therapeutic yields achieved within reasonable procedure duration and here we present a large retrospective multicenter US study evaluating the use, yield, and complications of DAE. METHODS: After obtaining institutional review board approval, electronic records were used to identify all DAE's performed for luminal small bowel evaluation in adult patients at 4 US referral centers (Duke University Medical Center, New York University Langone Medical Center, Louisiana State University Health Sciences Center, and University of Massachusetts Medical Center) from January 1, 2014 to January 1, 2019. Electronic medical records were reviewed to collect and analyze a variety of procedure-related outcomes. Using the data pooled across centers, descriptive statistics were generated for the patient and procedure-related characteristics and outcomes; relationships between characteristics and outcomes were explored. RESULTS: A total of 1787 DAE's were performed over this 5-year period (392 at Duke University Medical Center, 887 at Louisiana State University Health Sciences Center, 312 at New York University Langone Medical Center, and 195 at University of Massachusetts Medical Center). Of these, there were 1017 (57%) double-balloon, 391 (29%) single-balloon, and 378 (21%) spiral enteroscopies. The mean age of patients undergoing DAE was 66 years and 53% of examinations were performed on women; 18% of patients in the cohort underwent >1 DAE over this time span. A total of 53% of examinations were performed for suspected small bowel bleeding, 31% were directly guided by video capsule endoscopy findings and 8% were performed for abnormal imaging. A total of 85% of examinations used an antegrade approach and DAE took a mean of 45 minutes to complete; 76% of examinations revealed abnormal findings, with vascular, inflammatory, and neoplastic findings seen in 49%, 17%, and 15% of the cohort, respectively. Older age was significantly associated with any abnormal finding, including arteriovenous malformations (P<0.0001); 50% of examinations included a therapeutic maneuver, most commonly argon plasma coagulation/cautery (43%). There were complications in 16 examinations (0.9%) including 2 perforations (0.1%), 6 cases with bleeding (0.3%) and 1 episode of pancreatitis (0.1%). CONCLUSIONS: DAE is most commonly performed to evaluate suspected small bowel bleeding and is commonly directed by video capsule findings. DAE is safe, has a high diagnostic yield, with 76% of examinations showing abnormal findings, and frequently features therapeutic maneuvers. Advancing age is associated with abnormal findings on DAE.


Subject(s)
Capsule Endoscopy , Intestinal Diseases , Adult , Aged , Double-Balloon Enteroscopy , Female , Gastrointestinal Hemorrhage/diagnosis , Gastrointestinal Hemorrhage/etiology , Humans , Intestinal Diseases/diagnosis , Intestine, Small/diagnostic imaging , Retrospective Studies , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...