Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Obstet Gynecol ; 215(4): 480.e1-480.e10, 2016 10.
Article in English | MEDLINE | ID: mdl-27267388

ABSTRACT

BACKGROUND: Quantitative fetal fibronectin testing has demonstrated accuracy for prediction of spontaneous preterm birth in asymptomatic women with a history of preterm birth. Predictive accuracy in women with previous cervical surgery (a potentially different risk mechanism) is not known. OBJECTIVE: We sought to compare the predictive accuracy of cervicovaginal fluid quantitative fetal fibronectin and cervical length testing in asymptomatic women with previous cervical surgery to that in women with 1 previous preterm birth. STUDY DESIGN: We conducted a prospective blinded secondary analysis of a larger observational study of cervicovaginal fluid quantitative fetal fibronectin concentration in asymptomatic women measured with a Hologic 10Q system (Hologic, Marlborough, MA). Prediction of spontaneous preterm birth (<30, <34, and <37 weeks) with cervicovaginal fluid quantitative fetal fibronectin concentration in primiparous women who had undergone at least 1 invasive cervical procedure (n = 473) was compared with prediction in women who had previous spontaneous preterm birth, preterm prelabor rupture of membranes, or late miscarriage (n = 821). Relationship with cervical length was explored. RESULTS: The rate of spontaneous preterm birth <34 weeks in the cervical surgery group was 3% compared with 9% in previous spontaneous preterm birth group. Receiver operating characteristic curves comparing quantitative fetal fibronectin for prediction at all 3 gestational end points were comparable between the cervical surgery and previous spontaneous preterm birth groups (34 weeks: area under the curve, 0.78 [95% confidence interval 0.64-0.93] vs 0.71 [95% confidence interval 0.64-0.78]; P = .39). Prediction of spontaneous preterm birth using cervical length compared with quantitative fetal fibronectin for prediction of preterm birth <34 weeks of gestation offered similar prediction (area under the curve, 0.88 [95% confidence interval 0.79-0.96] vs 0.77 [95% confidence interval 0.62-0.92], P = .12 in the cervical surgery group; and 0.77 [95% confidence interval 0.70-0.84] vs 0.74 [95% confidence interval 0.67-0.81], P = .32 in the previous spontaneous preterm birth group). CONCLUSION: Prediction of spontaneous preterm birth using cervicovaginal fluid quantitative fetal fibronectin in asymptomatic women with cervical surgery is valid, and has comparative accuracy to that in women with a history of spontaneous preterm birth.


Subject(s)
Cervical Length Measurement , Cervix Uteri/surgery , Fetus/chemistry , Fibronectins/analysis , Premature Birth/diagnosis , Area Under Curve , Body Fluids/chemistry , Female , Fetal Membranes, Premature Rupture , Gestational Age , Humans , Parity , Pregnancy , Prospective Studies , ROC Curve , Risk Factors , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...