Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
J Atr Fibrillation ; 10(1): 1531, 2017.
Article in English | MEDLINE | ID: mdl-29250220

ABSTRACT

INTRODUCTION: Restoration of normal sinus rhythm by radiofrequency ablation (RFA) in atrial fibrillation (AF) patients can result in a reduction of left atrial (LA) volume and pulmonary vein (PV) dimensions. It is not clear if this PV size reduction represents a secondary effect of overall LA volume reduction or true PV stenosis. We assessed the relationship between LA volume reduction and PV orifice area pre- and post-RFA. METHODS: A retrospective cohort study was conducted at a tertiary care academic hospital. Pre- and post-RFA cardiac computed tomography (CT) studies of 100 consecutive AF patients were reviewed. Studies identifying obvious segmental PV narrowing were excluded. Left atrial volumes and PV orifice cross-sectional areas (PVOCA) were measured using proprietary software from the CT scanner vendor (GE Healthcare, Waukesha, WI). RESULTS: The cohort had a mean age of 60 ± 8 years, 73% were male, and 90% were Caucasian. Non-paroxysmal AF was present in 76% of patients with a mean duration from diagnosis to RFA of 55 ± 54 months. Mean procedural time was 244 ± 70 min. AF recurred in 27% at 3 month follow-up. Pre-RFA LA volumes were 132 ± 60 ml and mean PVOCA was 2.89 ± 2.32 cm2. In patients with successful ablation, mean LA volume decreased by 10% and PVOCA decreased by 21%. PVOCA was significantly reduced in patients with successful RFA compared to those who had recurrence (2.18 ± 1.12 vs. 2.8 ± 1.9 cm2, p = 0.04) but reduction in LA volume between groups was not significant (118 ± 42 vs. 133 ± 54 ml, p=0.15). CONCLUSIONS: The study demonstrates that both PV orifice dimensions and LA volume are reduced after successful AF ablation. These data warrant a reassessment of criteria for diagnosing PV stenosis based on changes in PV caliber alone, ideally incorporating LA volume changes.

2.
Am J Ther ; 23(6): e1781-e1787, 2016.
Article in English | MEDLINE | ID: mdl-27219536

ABSTRACT

The objective of this study was to examine the clinical determinants of incidence and prognosis of arrhythmias in the setting of acute brain injury. Acute brain injury is known to cause electrocardiographic abnormalities and cardiac arrhythmias. The relation between partial brain tissue oxygen (PBTO) and intracranial pressure (ICP) with arrhythmia incidence and prognosis remains unknown. Consecutive patients with acute brain injury and intracranial bleed admitted to the neurosurgical intensive care unit were enrolled in the study. Baseline characteristics [demographics, medical history, etiology of brain injury, Glasgow Coma Scale (GCS) score, blood pressure, and respiratory rate] were documented. Patient's telemetry recordings were reviewed for daily mean heart rates and arrhythmias. If arrhythmia was noted, PBTO levels at the beginning of arrhythmia, ICP, brain tissue temperature, and outcomes were recorded. A total of 106 subjects (53% men, age 39 ± 18 years, 65 traumatic and 41 nontraumatic brain injuries) were studied. Overall, 62% of subjects developed a total of 241 arrhythmia episodes. Ventricular arrhythmias were associated with significantly higher daily mean heart rates, low PBTO levels, and low GCS scores, whereas atrial arrhythmias were associated with lower daily mean heart rates, normal PBTO levels, and higher GCS and ICP. Three or more episodes of arrhythmia predicted worse outcomes, including mortality (P = 0.001). In patients with acute brain injury, poor PBTO levels are associated with higher incidence of ventricular tachyarrhythmias. In contrast, atrial tachyarrhythmias occur in patients with normal PBTO levels and higher ICP. Incidence of ventricular arrhythmia in those with poor PBTO is associated with increased mortality.


Subject(s)
Arrhythmias, Cardiac/epidemiology , Brain Injuries/complications , Intracranial Pressure/physiology , Oxygen/metabolism , Adult , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/mortality , Brain/metabolism , Brain/physiopathology , Brain Injuries/mortality , Brain Injuries/physiopathology , Electrocardiography , Female , Glasgow Coma Scale , Heart Rate/physiology , Humans , Incidence , Male , Middle Aged , Prognosis , Prospective Studies , Telemetry , Young Adult
3.
J Atr Fibrillation ; 5(5): 342, 2013.
Article in English | MEDLINE | ID: mdl-28496802

ABSTRACT

A 61 year old patient with non-ischemic cardiomyopathy and implantable cardioverter defibrillator presented with multiple shocks for ventricular tachycardia (VT). EKG revealed monomorphic sustained VT which was left bundle inferior axis that spontaneously changed into sustained VT which was right bundle superior axis. This was suggestive of an outflow tract VT transforming into a VT probably related to reentry from LV scar. The patient was transferred to our university for VT ablation. However, further investigation revealed amiodarone induced hyperthyroidism which was the cause of his ventricular tachycardia storm. Reversible causes of VT should be considered before proceeding with radiofrequency ablation.

4.
J Am Coll Cardiol ; 59(13): 1168-74, 2012 Mar 27.
Article in English | MEDLINE | ID: mdl-22305113

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the feasibility and safety of periprocedural dabigatran during atrial fibrillation (AF) ablation. BACKGROUND: AF ablation requires optimal periprocedural anticoagulation for minimizing bleeding and thromboembolic complications. The safety and efficacy of dabigatran as a periprocedural anticoagulant for AF ablation are unknown. METHODS: We performed a multicenter, observational study from a prospective registry including all consecutive patients undergoing AF ablation in 8 high-volume centers in the United States. All patients receiving dabigatran therapy who underwent AF ablation on periprocedural dabigatran, with the dose held on the morning of the procedure, were matched by age, sex, and type of AF with an equal number of patients undergoing AF ablation with uninterrupted warfarin therapy over the same period. RESULTS: A total of 290 patients, including 145 taking periprocedural dabigatran and an equal number of matched patients taking uninterrupted periprocedural warfarin, were included in the study. The mean age was 60 years with 79% being male and 57% having paroxysmal AF. Both groups had a similar CHADS(2) score, left atrial size, and left ventricular ejection fraction. Three thromboembolic complications (2.1%) occurred in the dabigatran group compared with none in the warfarin group (p = 0.25). The dabigatran group had a significantly higher major bleeding rate (6% vs. 1%; p = 0.019), total bleeding rate (14% vs. 6%; p = 0.031), and composite of bleeding and thromboembolic complications (16% vs. 6%; p = 0.009) compared with the warfarin group. Dabigatran use was confirmed as an independent predictor of bleeding or thromboembolic complications (odds ratio: 2.76, 95% confidence interval: 1.22 to 6.25; p = 0.01) on multivariate regression analysis. CONCLUSIONS: In patients undergoing AF ablation, periprocedural dabigatran use significantly increases the risk of bleeding or thromboembolic complications compared with uninterrupted warfarin therapy.


Subject(s)
Anticoagulants/therapeutic use , Atrial Fibrillation/therapy , Benzimidazoles/therapeutic use , Registries , Warfarin/therapeutic use , beta-Alanine/analogs & derivatives , Aged , Anticoagulants/adverse effects , Benzimidazoles/adverse effects , Catheter Ablation , Dabigatran , Feasibility Studies , Female , Hemorrhage/chemically induced , Humans , Male , Middle Aged , Perioperative Care , Prospective Studies , Thromboembolism/chemically induced , Treatment Outcome , beta-Alanine/adverse effects , beta-Alanine/therapeutic use
5.
Pacing Clin Electrophysiol ; 35(6): e163-6, 2012 Jun.
Article in English | MEDLINE | ID: mdl-21029124

ABSTRACT

Fluctuation of impedance on defibrillator leads is highly suggestive of lead failure. A drop in impedance is associated with insulation defects while high impedance is suggestive of lead fracture. In this case report, we described a patient where electromagnetic interference from radiofrequency ablation near the site of superior vena cava coil caused the sensed impedance to fluctuate without uneventful outcomes and we discussed the possible mechanism. Both electromagnetic interference and defibrillator lead insulation defect can result in low threshold and inappropriate shocks. Sometimes electromagnetic interference may result in physical damage of the implanted system and may result in subsequent fluctuations in impedance. Awareness of electromagnetic interference that can cause fluctuating impedance without structural damage can help in making appropriate diagnosis and may avoid unnecessary procedures.


Subject(s)
Artifacts , Atrial Fibrillation/prevention & control , Atrial Fibrillation/surgery , Defibrillators, Implantable , Electrodes, Implanted , Equipment Failure , Aged , Electric Impedance , Equipment Failure Analysis/methods , Humans , Male
6.
Am J Cardiol ; 109(3): 359-63, 2012 Feb 01.
Article in English | MEDLINE | ID: mdl-22071212

ABSTRACT

Recent evidence supports an association between vitamin D deficiency and hypertension, peripheral vascular disease, diabetes mellitus, metabolic syndrome, coronary artery disease, and heart failure. The effect of vitamin D supplementation, however, has not been well studied. We examined the associations between vitamin D deficiency, vitamin D supplementation, and patient outcomes in a large cohort. Serum vitamin D measurements for 5 years and 8 months from a large academic institution were matched to patient demographic, physiologic, and disease variables. The vitamin D levels were analyzed as a continuous variable and as normal (≥30 ng/ml) or deficient (<30 ng/ml). Descriptive statistics, univariate analysis, multivariate analysis, survival analysis, and Cox proportional hazard modeling were performed. Of 10,899 patients, the mean age was 58 ± 15 years, 71% were women (n = 7,758), and the average body mass index was 30 ± 8 kg/m(2). The mean serum vitamin D level was 24.1 ± 13.6 ng/ml. Of the 10,899 patients, 3,294 (29.7%) were in the normal vitamin D range and 7,665 (70.3%) were deficient. Vitamin D deficiency was associated with several cardiovascular-related diseases, including hypertension, coronary artery disease, cardiomyopathy, and diabetes (all p <0.05). Vitamin D deficiency was a strong independent predictor of all-cause death (odds ratios 2.64, 95% confidence interval 1.901 to 3.662, p <0.0001) after adjusting for multiple clinical variables. Vitamin D supplementation conferred substantial survival benefit (odds ratio for death 0.39, 95% confidence interval 0.277 to 0.534, p <0.0001). In conclusion, vitamin D deficiency was associated with a significant risk of cardiovascular disease and reduced survival. Vitamin D supplementation was significantly associated with better survival, specifically in patients with documented deficiency.


Subject(s)
Cardiovascular Diseases/etiology , Dietary Supplements , Vitamin D Deficiency/complications , Vitamin D/therapeutic use , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/prevention & control , Female , Follow-Up Studies , Humans , Incidence , Kansas/epidemiology , Male , Middle Aged , Prognosis , Retrospective Studies , Risk Factors , Survival Rate/trends , Vitamin D/pharmacokinetics , Vitamin D Deficiency/blood , Vitamin D Deficiency/drug therapy , Vitamins/pharmacokinetics , Vitamins/therapeutic use
7.
Heart Rhythm ; 8(7): 975-80, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21316485

ABSTRACT

BACKGROUND: Patients with prosthetic valves have a high prevalence of atrial fibrillation (AF). We report a multicenter experience of performing pulmonary vein antral isolation (PVAI) in this challenging, high-risk cohort of patients. OBJECTIVE: The purpose of this study was to assess the feasibility, safety, and efficacy of radiofrequency (RF) ablation for sinus rhythm restoration in AF patients with mitral or aortic mechanical prosthetic valves. METHODS: A total of 50 patients with prosthetic valves (group I) who underwent RF ablation for AF between January 1, 2007, and April 30, 2009, were identified prospectively at four tertiary care centers. A matched group of 50 patients (group II) acted as controls. RESULTS: Total procedural time (199.4 ± 49 minutes vs 166.6 ± 27.5 minutes, P <.001) and fluoroscopy time (60 ± 17 minutes vs 53.8 ± 6.8 minutes, P <.01) were prolonged, with a higher incidence of atrial flutter at 3 months in group I (18% vs 6%, P = .1) compared to group II. At 12 months, 80% of patients in the valve group were in sinus rhythm after an average of 1.3 procedures, and 82% of controls were in sinus rhythm after an average 1.2 procedures (P = .9). There was a trend toward a higher nonfatal complication rate in the valve group than in the control group (8% vs 4%, P = .1). CONCLUSION: In patients with prosthetic valves, RF ablation for AF is feasible, safe, and efficacious, with a trend toward a higher nonfatal complication rate and an increased rate of postablation atrial flutter.


Subject(s)
Aortic Valve , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Rate/physiology , Heart Valve Diseases/complications , Heart Valve Prosthesis , Mitral Valve , Atrial Fibrillation/etiology , Atrial Fibrillation/physiopathology , Electrocardiography, Ambulatory , Feasibility Studies , Female , Follow-Up Studies , Heart Conduction System/physiopathology , Heart Conduction System/surgery , Heart Valve Diseases/physiopathology , Heart Valve Diseases/surgery , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Retrospective Studies , Treatment Outcome
9.
Indian Pacing Electrophysiol J ; 9(6): 351-4, 2009 Nov 01.
Article in English | MEDLINE | ID: mdl-19898658

ABSTRACT

Management of ventricular tachycardia (VT) storm in a patient with an implantable cardioverter-defibrillator (ICD) is a challenging medical emergency. We describe a patient with cardiac sarcoidosis (CS) and an ICD who is admitted with VT storm. Management of VT was difficult due to resistance to multiple antiarrhythmic drugs. He responded to immunosuppressive therapy supporting active CS as the cause of his VT. This case suggests that CS may underlie some cases of refractory VT and that immunosuppressive therapy may be effective in controlling this arrhythmia.

10.
J Atr Fibrillation ; 1(2): 88, 2008.
Article in English | MEDLINE | ID: mdl-28496580

ABSTRACT

Radiofrequency Ablation of AV node with permanent pacemaker has been used to achieve rate control in persistent symptomatic atrial fibrillation. Although RF Ablation is safe, complications may occur in up to 3% of the procedures. A rare complication of 2nd degree skin burn at indifferent electrode site has been described here. This report highlights the rare but possible complication in patients undergoing such a procedure and help in preventing by taking appropriate measures.

SELECTION OF CITATIONS
SEARCH DETAIL
...