Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Sci Sports Exerc ; 55(9): 1555-1563, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37093897

ABSTRACT

PURPOSE: Patellofemoral pain syndrome and patellar tendinopathy are important running-related overuse injuries. This study investigated the interaction of running speed and step frequency alterations on peak and cumulative patellofemoral joint stress (PFJS) and patellar tendon force (PTF) parameters. METHODS: Twelve healthy individuals completed an incremental running speed protocol on a treadmill at habitual, increased and decreased step frequency. Peak PFJS and PTF, peak rate of PFJS and PTF development, and PFJS and PTF impulse per kilometer (km) were calculated using musculoskeletal modeling. RESULTS: With increasing running speed, peak PFJS ( P < 0.001) and PTF ( P < 0.001) and peak rate of PFJS ( P < 0.001) and PTF ( P < 0.001) development increased, whereas PFJS ( P < 0.001) and PTF ( P < 0.001) impulse per km decreased. While increasing step frequency by 10%, the peak PFJS ( P < 0.001) and PTF ( P < 0.001) and the PFJS ( P < 0.001) and PTF ( P < 0.001) impulse per kilometer decreased. No significant effect of step frequency alteration was found for the peak rate of PFJS ( P = 0.008) and PTF ( P = 0.213) development. A significant interaction effect was found for PFJS ( P < 0.001) and PTF ( P < 0.001) impulse per km, suggesting that step frequency alteration was more effective at low running speed. CONCLUSIONS: The effectiveness of step frequency alteration on PFJS and PTF impulse per km is dependent on the running speed. With regard to peak PFJS and PTF, step frequency alteration is equally effective at low and high running speeds. Step frequency alteration was not effective for peak rate of PFJS and PTF development. These findings can assist the optimization of patellofemoral joint and patellar tendon load management strategies.


Subject(s)
Patellar Ligament , Patellofemoral Joint , Patellofemoral Pain Syndrome , Humans , Biomechanical Phenomena , Exercise Test
2.
Musculoskelet Sci Pract ; 59: 102532, 2022 06.
Article in English | MEDLINE | ID: mdl-35245881

ABSTRACT

INTRODUCTION: Magnetic resonance imaging (MRI) is the standard to quantify size and structure of lumbar muscles. Three-dimensional volumetric measures are expected to be more closely related to muscle function than two-dimensional measures such as cross-sectional area. Reliability and agreement of a standardized method should be established to enable the use of MRI to assess lumbar muscle characteristics. OBJECTIVES: This study investigates the intra- and inter-processor reliability for the quantification of (1) muscle volume and (2) fat fraction based on chemical shift MRI images using axial 3D-volume measurements of the lumbar multifidus in patients with low back pain. METHODS: Two processors manually segmented the lumbar multifidus on the MRI scans of 18 patients with low back pain using Mevislab software following a well-defined method. Fat fraction of the segmented volume was calculated. Reliability and agreement were determined using intra-class correlation coefficients (ICC), Bland-Altman plots and calculation of the standard error of measurement (SEM) and minimal detectable change (MDC). RESULTS: Excellent ICCs were found for both intra-processor and inter-processor analysis of lumbar multifidus volume measurement, with slightly better results for the intra-processor reliability. The SEMs for volume were lower than 4.1 cm³. Excellent reliability and agreement were also found for fat fraction measures, with ICCs of 0.985-0.998 and SEMs below 0.946%. CONCLUSION: The proposed method to quantify muscle volume and fat fraction of the lumbar multifidus on MRI was highly reliable, and can be used in further research on lumbar multifidus structure.


Subject(s)
Low Back Pain , Paraspinal Muscles , Humans , Low Back Pain/diagnostic imaging , Lumbosacral Region/diagnostic imaging , Magnetic Resonance Imaging/methods , Paraspinal Muscles/diagnostic imaging , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...