Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 22(22)2022 Nov 08.
Article in English | MEDLINE | ID: mdl-36433207

ABSTRACT

In this paper, we present how complementary characterization techniques, such as electrical measurements with a vector network analyzer (VNA), optical measurements with a laser Doppler vibrometer (LDV), and numerical simulations with the finite element method, coupled with spectral domain analysis (FEMSDA), allow us to independently access different properties of a SAW device and fully characterize its operation using the coupling-of-modes theory (COM). A set of chemical SAW sensors coated with parylene C layers of different thicknesses (1, 1.5, and 2 µm) and an uncoated sensor were used as test samples. The sensors represent dual-channel electroacoustic delay lines operating in the vicinity of 77 MHz. The IDTs consist of split aluminum electrodes deposited on a AT-cut quartz substrate. The thickness-dependent influence of the parylene C layer was observed on the operating frequency (SAW velocity), static capacitance, attenuation, crosstalk, and reflection coefficient. COM parameters were reported for the four cases considered; measured and simulated data show good agreement. The presented approach is suitable for the design, characterization, and validation of polymer film-coated SAW sensors.

2.
Sensors (Basel) ; 18(1)2018 Jan 16.
Article in English | MEDLINE | ID: mdl-29337916

ABSTRACT

In this research, Surface Acoustic Wave (SAW) sensors are combined with a cascade impactor to perform real time PM10 and PM2.5 mass concentration measurements. The SAW sensors consist of 125 MHz delay lines based on Love waves propagating on an AT-cut quartz substrate. The Love waves are guided on the substrate's surface using a silica layer. SAW sensors themselves are not capable to discriminate particles by their size, therefore, particle separation based on aerodynamic diameter is achieved using a 3 Lpm dedicated cascade impactor. The latter was designed to integrate the SAW sensors which are monitored using a phase shift measurement. The collected particles impact on the acoustic sensor's surface inducing a gravimetric effect that modifies the acoustic wave propagation conditions. The resulted phase shift allows the measurement of the mass deposited on the sensitive zone. The novel cascade impactor with SAW sensors as particle collecting stages is exposed to different aerosols in the 0-150 µg/m³ concentration range and proved to be able to detect and differentiate particles based on their size in real time. The system's response was compared to a commercial optical counter based on light scattering technology and was found to be in good agreement with it.

SELECTION OF CITATIONS
SEARCH DETAIL
...