1.
Br J Radiol ; 76(910): 726-30, 2003 Oct.
Article in English | MEDLINE | ID: mdl-14512333

ABSTRACT

The purpose of this study was to collect information on the practice and patient doses in a major Greek cardiac centre, investigate differences between senior cardiologists of various levels of experience and compare results with the literature, in order to optimize angiographic and interventional cardiology procedures. Radiation doses from 292 patients have been studied, 195 of which had undergone coronary angiography and 97 percutaneous transluminal coronary angioplasty. All procedures were undertaken on a Siemens Angioscop X-ray equipment. The system performed under automatic exposure control using pulsed fluoroscopy of 12.5 pulses s(-1) and cine frame rate of 25 frames s(-1). Dose-area product values, fluoroscopy times, total number of cine frames as well as operator's name were collected for each patient. Only senior cardiologists have participated in the study. Median values for dose-area product were 39.1 Gy cm(2) for coronary angiography and 58.3 Gy cm(2) for percutaneous transluminal coronary angioplasty. Median fluoroscopy time was 5.0 min and 9.7 min and median number of frames was 1588 and 1823 for coronary angiography and percutaneous transluminal coronary angioplasty, respectively. Comparison showed that patient dose-area product values were lower than other studies and fluoroscopy time values were comparable. However, the total number of frames used was much higher than other published results. Differences between cardiologists with increased experience have been found. Analysis of the patient dose values obtained initiated a program of radiation protection optimization. The need for continuous training in radiation protection for interventionalists has been verified.


Subject(s)
Coronary Angiography/methods , Coronary Disease/therapy , Adult , Age Distribution , Aged , Aged, 80 and over , Angioplasty, Balloon, Coronary/methods , Cardiac Care Facilities , Clinical Competence , Coronary Disease/diagnostic imaging , Female , Fluoroscopy/methods , Greece , Humans , Male , Medical Staff, Hospital , Middle Aged , Radiation Dosage , Radiography, Interventional
2.
Radiat Prot Dosimetry ; 93(1): 31-41, 2001.
Article in English | MEDLINE | ID: mdl-11548324

ABSTRACT

This study deals with the estimation of doses received by patients undergoing radiological examinations in order to establish diagnostic reference levels (DRLs) within the process of optimisation of patients' exposure in Greece. Six large hospitals in Athens were selected and 385 patients made up the sample. The entrance surface doses (ESDs) to patients undertaking five common X ray examinations (chest, cervical spine, lumbar spine AP and LAT, pelvis) were estimated using both thermoluminescence dosemeters (TLDs) attached to the patient's skin and an ionisation chamber for air kerma measurements. Exposure settings and patient's data were recorded. Results concerning the kilovoltage and focus-to-film-distance (FFD) settings and the ESD values were analysed and compared to those recommended by the EU. Discrepancies in the patient doses and techniques used for the examinations studied were found among the different hospitals denoting the importance of establishing a national quality assurance programme and examination protocols to ensure patient doses are kept as low as possible. All the examinations studied fulfilled the EU recommendations except that for the chest where the doses were considerably higher due to the use of low kVP settings.


Subject(s)
Radiation Dosage , Radiography , Adolescent , Adult , Aged , Aged, 80 and over , Body Constitution , Female , Greece , Humans , Male , Middle Aged , Pelvis/diagnostic imaging , Radiation Monitoring , Radiography, Thoracic , Spine/diagnostic imaging