Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Front Cardiovasc Med ; 10: 1142575, 2023.
Article in English | MEDLINE | ID: mdl-37034355

ABSTRACT

The global population is estimated to reach 9.8 billion by 2050, of which 2.1 billion will comprise individuals above 60 years of age. As the number of elderly is estimated to double from 2017, it is a victory of the modern healthcare system but also worrisome as ageing, and the onset of chronic disease are correlated. Among other chronic conditions, cardiovascular diseases (CVDs) are the leading cause of death in the aged population. While the underlying cause of the age-associated development of CVDs is not fully understood, studies indicate the role of non-coding RNAs such as microRNAs (miRNAs) and long noncoding RNAs (lnc-RNAs) in the development of age-associated CVDs. miRNAs and lnc-RNAs are non-coding RNAs which control gene expression at the post-transcriptional level. The expression of specific miRNAs and lnc-RNAs are reportedly dysregulated with age, leading to cardiovascular system changes and ultimately causing CVDs. Since miRNAs and lnc-RNAs play several vital roles in maintaining the normal functioning of the cardiovascular system, they are also being explored for their therapeutic potential as a treatment for CVDs. This review will first explore the pathophysiological changes associated with ageing. Next, we will review the known mechanisms underlying the development of CVD in ageing with a specific focus on miRNA and lnc-RNAs. Finally, we will discuss the therapeutic options and future challenges towards healthy cardiac ageing. With the global ageing population on the rise, this review will provide a fundamental understanding of some of the underlying molecular mechanisms of cardiac ageing.

2.
Catheter Cardiovasc Interv ; 97(5): 815-824, 2021 04 01.
Article in English | MEDLINE | ID: mdl-32294309

ABSTRACT

OBJECTIVES: To study the safety of stent avoidance, frequency of change in management decisions, and its cost implications while using a fractional flow reserve (FFR)-guided treatment strategy for intermediate-grade coronary artery stenosis. BACKGROUND: The impact of FFR in guiding management decisions and its cost implications has not been studied after imposition of a ceiling on stent prices by the Government of India. METHODS: In 400 patients with 477 intermediate-grade coronary lesions for whom coronary intervention was planned, functional assessment using FFR was done. Incidence of the primary composite endpoint (major adverse cardiac event [MACE], cardiac death, myocardial infarction, objective evidence of ischemia, and target vessel revascularization) in the stent avoided subset was compared with the stented group at follow-up. Micro-costing analysis was done using a computed model with current stent and FFR wire prices. RESULTS: The overall incidence of MACE was 4.9%, 0.9% in the stent-avoided subset and 6.9% in stented group (p = 0.04, comparing the latter two) at a median follow-up of 21 months (interquartile range 12-31 months). Serious adverse events occurred only in 1% of patients receiving adenosine. The average cost saving was Indian rupees (INR) 51,847 [United States Dollar (USD) 746] per patient, resulting in total savings of INR 15,813,379 (USD 227,530). Cost savings persisted but were lower by 36% (INR 18,613/USD 268 per patient) after the ceiling of stent prices. CONCLUSION: FFR-guided percutaneous coronary intervention (PCI) strategy is safe and cost-effective in countries where majority of patients self-finance their health care, resulting in stent and PCI avoidance in approximately one in three patients referred for coronary angioplasty.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/therapy , Humans , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome
3.
Ann Pediatr Cardiol ; 13(3): 238-240, 2020.
Article in English | MEDLINE | ID: mdl-32863661

ABSTRACT

Cardiac tumors in neonates and infancy are one among the many known congenital cardiac diseases. Although fetal cardiac tumors are rare, there is increased detection because of expertise in echocadiographic examination. Rhabdomyomas are the most common cardiac tumors among infants and children. Here, we describe twin neonates who had multiple cardiac tumors. This kind of presentation appears to be a very rare situation.

5.
Ann Pediatr Cardiol ; 13(1): 95-97, 2020.
Article in English | MEDLINE | ID: mdl-32030045

ABSTRACT

Congenital mitral stenosis (MS) is a spectrum of anomalies that result in functional and anatomic obstruction of inflow into the left ventricle. Mitral arcade is one of the varieties of congenital MS where there is an abnormal development of chordae tendineae, resulting in stenosis, regurgitation, or both. Here, we describe the case of a mitral arcade in a child, which was diagnosed on echocardiography and confirmed with other imaging modalities.

6.
J Invasive Cardiol ; 31(11): E337-E338, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31671065

ABSTRACT

OCT imaging revealed a 1.5 mm-long transmural breach in a segment of the artery devoid of calcium or eccentric plaque burden. Focal negative remodeling identified on OCT was deemed the reason for this otherwise unexplained cause of coronary rupture.


Subject(s)
Angioplasty, Balloon, Coronary/adverse effects , Anterior Wall Myocardial Infarction/surgery , Blood Vessel Prosthesis Implantation/methods , Coronary Vessels/injuries , Stents , Tomography, Optical Coherence/methods , Vascular System Injuries/diagnosis , Anterior Wall Myocardial Infarction/diagnosis , Coronary Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Follow-Up Studies , Humans , Male , Middle Aged , Reoperation , Rupture , Vascular System Injuries/surgery
7.
J Radiol Prot ; 38(2): 511-524, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29380743

ABSTRACT

The radiation dose from complex cardiac procedures is of concern due to the lengthy fluoroscopic screening time and vessel complexities. This study intends to assess radiation dose based on angiographic projection and vessel complexities for clinical protocols used in the performance of percutaneous transluminal coronary angioplasty (PTCA). Dose-area product (DAP), reference air kerma (K a,r) and real-time monitoring of tube potentials and tube current for each angiographic projection and dose setting were evaluated for 66 patients who underwent PTCA using a flat detector system. The mean DAP and cumulative K a,r were 32.71 Gy cm2 (0.57 Gy), 51.24 Gy cm2 (0.9 Gy) and 102.03 Gy cm2 (1.77 Gy) for single-, double- and triple-vessel PTCA, respectively. Among commonly used angiographic projections, left anterior oblique 45°-caudal 35° reached 2 Gy in 55 min using a low-dose fluoroscopy setting and 21 min for a medium-dose setting. Use of a low-dose setting for fluoroscopic screening showed a radiation dose reduction of 39% compared with a medium-dose setting.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Angiography , Radiation Dosage , Adult , Aged , Angioplasty, Balloon, Coronary/instrumentation , Female , Humans , Male , Middle Aged
8.
Heart Asia ; 9(2): e010915, 2017.
Article in English | MEDLINE | ID: mdl-29560043

ABSTRACT

DESCRIPTION OF THE CASE: A 38-year-old male presented with history of progressively increasing dyspnoea of 25 days duration. He gave history of low -grade fever associated with malaise and weight loss over the preceding 6 months. He worked in the dairy industry in the Middle East and returned to India owing to his illness. On clinical examination, he was found to be tachypneic and cachectic. Jugular venous pressure was raised with a prominent 'a' wave. There was a short early diastolic murmur over the aortic area. His blood investigations, including renal and liver function tests, were normal. Three sets of blood cultures were sterile. Two-dimensional trans-thoracic and trans-oesophageal echocardiography revealed thickened bicuspid aortic valve cusps, with moderate eccentric aortic regurgitation and an abnormal structure posterior to the left ventricular outflow tract and aorta (figure 1A-C). A small vegetation was seen attached to the fused right-left aortic cusp (supplementary figure 1). The patient was started on appropriate intravenous antibiotics and antifailure medications, and was referred for early surgical treatment.Figure 1(A) Transthoracic echocardiography parasternal long axis view. (B) Transesophageal echocardiography (mid esophageal level) long axis view. (C) Transthoracic echocardiography parasternal short axis view.10.1136/heartasia-2017-010915.supp1Supplementary Figure 1. QUESTION: Identify the structure depicted in the images (figure 1A-C).Answer options:Cor triatriatumAortic dissectionLeft atrial pseudoaneurysmPseudoaneurysm of the mitral aortic inter-valvular fibrosaAortic root abscess.

9.
J Appl Clin Med Phys ; 17(3): 433-441, 2016 05 08.
Article in English | MEDLINE | ID: mdl-27167263

ABSTRACT

Coronary angiography (CA) procedure uses various angiographic projections to elicit detailed information of the coronary arteries with some steep projections involving high radiation dose to patients. This study intends to evaluate radiation doses and estimated risk from angiographic projections during CA procedure performed using novel flat detector (FD) system with improved image processing and noise reduction techniques. Real-time monitoring of radiation doses using kerma-area product (KAP) meter was performed for 140 patients using Philips Clarity FD system. The CA procedure involved seven standard projections, of which five were extensively selected by interventionalists. Mean fluoroscopic time (FT), KAP, and reference air kerma (Ka,r) for CA procedure were 3.24 min (0.5-10.51), 13.99Gycm2 (4.02-37.6), and 231.43 mGy (73.8-622.15), respectively. Effective dose calculated using Monte Carlo-based PCXMC software was found to be 4.9mSv. Left anterior oblique (LAO) 45° projection contributed the highest radiation dose (28%) of the overall KAP. Radiation-induced risk was found to be higher in females compared to males with increased risk of lung cancer. An increase of 10%-15% in radiation dose was observed when one or more additional projections were adopted along with the seven standard projections. A 14% reduction of radiation dose was achieved from novel FD system when low-dose protocol during fluoroscopy and medium-dose protocol during cine acquisitions were adopted, compared to medium-dose protocol.


Subject(s)
Cardiac Catheterization/methods , Coronary Angiography/instrumentation , Coronary Angiography/methods , Fluoroscopy/methods , Organs at Risk/radiation effects , Radiation Monitoring/instrumentation , Female , Humans , Male , Radiation Dosage , Radiography, Interventional
10.
Indian Heart J ; 66(5): 503-5, 2014.
Article in English | MEDLINE | ID: mdl-25443602

ABSTRACT

AIMS: Coronary artery disease is the leading cause of mortality and morbidity in our country, of which ST elevation myocardial infarction (STEMI) accounts for the major part of health spending. We sought to study the effect of induction of government health insurance scheme on the trends of reperfusion in patients of acute STEMI. METHODS AND RESULTS: 1133 patients presenting with acute STEMI enrolled. 1079 (95.1%) received some form of reperfusion therapy. Primary PCI was used in 60.6% of patients as the primary reperfusion modality, a six fold increase as compared to previous years. Government health insurance accounted for the one third of all. 34.5% patients underwent pharmacological reperfusion, most commonly with streptokinase. 4.9% patients of STEMI did not receive any form of reperfusion therapy in contrast to 14% during previous years. CONCLUSION: Introduction of government health insurance along with increased awareness has resulted in dramatic changes in the management of STEMI patients.


Subject(s)
Government Programs , Insurance, Health , Myocardial Infarction/economics , Myocardial Infarction/therapy , Myocardial Reperfusion/economics , Myocardial Reperfusion/methods , Comorbidity , Female , Humans , India , Male , Middle Aged , Retrospective Studies , Tertiary Care Centers
11.
J Endovasc Ther ; 20(5): 638-46, 2013 Oct.
Article in English | MEDLINE | ID: mdl-24093315

ABSTRACT

PURPOSE: To report the bench-top evaluation and initial clinical use of an instrument for on-site fenestration of aortic stent-grafts. METHODS: A stainless steel thermal cautery instrument was designed to create circular stent-graft fenestrations from 3 to 10 mm in diameter. Three operators independently bench-tested the instrument on thoracic stent-graft samples to evaluate size, shape, location, and quality of fenestrations created. For clinical use, on-site fenestration was performed 2 days before the endovascular procedure in a sterile room without access to supplemental oxygen. A fenestrator 1 or 2 mm smaller in diameter than the target vessel was used; the edges of the fenestrations were strengthened using flexible radiopaque nitinol wire. The aortic stent-graft was then re-sheathed and sterilized for added safety. Eighteen patients (17 men; mean age 51 years, range 18-80) with a variety of thoracic and juxtarenal pathologies were treated using Zenith TX2, Valiant Captivia, Zenith AAA, and Endurant stent-grafts modified in this manner. RESULTS: After successful bench testing, the instrument was used to create 34 fenestrations in aortic stent-grafts deployed in the 18 patients. Size and location of fenestrations obtained were as desired. Subsequent catheterization of the fenestration/target vessel and covered stent deployment were successfully achieved in 31 (91%) fenestrations; 2 fenestrations had type III endoleaks and 1 fenestration was unused. There was no perioperative mortality, stroke, embolization, vessel dissection, renal failure, or graft infection. Follow-up to 1 year in the majority of patients has revealed no new fenestration-related problems. CONCLUSION: This simple-to-use instrument makes on-site creation of aortic stent-graft fenestrations easy, accurate, and precise. The instrument is inexpensive, robust, and easily sterilized.


Subject(s)
Aorta, Abdominal/surgery , Aorta, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Cautery/instrumentation , Endovascular Procedures/instrumentation , Prosthesis Design , Stents , Adolescent , Adult , Aged , Aged, 80 and over , Alloys , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endovascular Procedures/adverse effects , Equipment Design , Feasibility Studies , Female , Humans , Male , Materials Testing , Middle Aged , Stainless Steel , Time Factors , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...