Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Medicina (Kaunas) ; 60(5)2024 May 16.
Article in English | MEDLINE | ID: mdl-38793002

ABSTRACT

Over the past decade, remote monitoring (RM) has become an increasingly popular way to improve healthcare and health outcomes. Modern cardiac implantable electronic devices (CIEDs) are capable of recording an increasing amount of data related to CIED function, arrhythmias, physiological status and hemodynamic parameters, providing in-depth and updated information on patient cardiovascular function. The extensive use of RM for patients with CIED allows for early diagnosis and rapid assessment of relevant issues, both clinical and technical, as well as replacing outpatient follow-up improving overall management without compromise safety. This approach is recommended by current guidelines for all eligible patients affected by different chronic cardiac conditions including either brady- and tachy-arrhythmias and heart failure. Beyond to clinical advantages, RM has demonstrated cost-effectiveness and is associated with elevated levels of patient satisfaction. Future perspectives include improving security, interoperability and diagnostic power as well as to engage patients with digital health technology. This review aims to update existing data concerning clinical outcomes in patients managed with RM in the wide spectrum of cardiac arrhythmias and Hear Failure (HF), disclosing also about safety, effectiveness, patient satisfaction and cost-saving.


Subject(s)
Heart Failure , Humans , Heart Failure/therapy , Heart Failure/diagnosis , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Monitoring, Physiologic/methods , Telemedicine/trends , Defibrillators, Implantable/standards
2.
Diagnostics (Basel) ; 14(2)2024 Jan 14.
Article in English | MEDLINE | ID: mdl-38248058

ABSTRACT

Fluoroscopy has always been the cornerstone imaging method of interventional cardiology procedures. However, radiation exposure is linked to an increased risk of malignancies and multiorgan diseases. The medical team is even more exposed to X-rays, and a higher incidence of malignancies was reported in this professional group. In the last years, X-ray exposure has increased rapidly, involving, above all, the medical team and young patients and forcing alternative fluoroless imaging methods. In cardiac electrophysiology (EP) and pacing, the advent of 3D electroanatomic mapping systems with dedicated catheters has allowed real-time, high-density reconstruction of both heart anatomy and electrical activity, significantly reducing the use of fluoroscopy. In addition, the diffusion of intracardiac echocardiography has provided high anatomical resolution of moving cardiac structures, providing intraprocedural guidance for more complex catheter ablation procedures. These methods have largely demonstrated safety and effectiveness, allowing for a dramatic reduction in X-ray delivery in most arrhythmias' ablations. However, some technical concerns, as well as higher costs, currently do not allow their spread out in EP labs and limit their use to only procedures that are considered highly complex and time-consuming and in young patients. In this review, we aim to update the current employment of fluoroless imaging in different EP procedures, focusing on its strengths and weaknesses.

3.
J Clin Med ; 13(2)2024 Jan 14.
Article in English | MEDLINE | ID: mdl-38256590

ABSTRACT

Arrhythmogenic cardiomyopathy (ACM) is a heart disease characterized by a fibrotic replacement of myocardial tissue and a consequent predisposition to ventricular arrhythmic events, especially in the young. Post-mortem studies and the subsequent diffusion of cardiac MRI have shown that left ventricular involvement in arrhythmogenic cardiomyopathy is common and often develops early. Regarding the arrhythmic risk stratification, the current scores underestimate the arrhythmic risk of patients with arrhythmogenic cardiomyopathy with left involvement. Indeed, the data on arrhythmic risk stratification in this group of patients are contradictory and not exhaustive, with the consequence of not correctly identifying patients at a high arrhythmic risk who deserve protection from arrhythmic death. We propose a literature review on arrhythmic risk stratification in patients with ACM and left involvement to identify the main features associated with an increased arrhythmic risk in this group of patients.

4.
J Clin Med ; 12(20)2023 Oct 22.
Article in English | MEDLINE | ID: mdl-37892813

ABSTRACT

BACKGROUND: Most recent cardiac implantable electronic devices (CIEDs) can safely undergo a cardiovascular magnetic resonance (CMR) scan under certain conditions, but metal artifacts may degrade image quality. The aim of this study was to assess the overall diagnostic yield of CMR and the extent of metal artifacts in a multicenter, multivendor study on CIED patients referred for CMR. METHODS: We analyzed 309 CMR scans from 292 patients (age 57 ± 16 years, 219 male) with an MR-conditional pacemaker (n = 122), defibrillator (n = 149), or loop recorder (n = 38); CMR scans were performed in 10 centers from 2012 to 2020; MR-unsafe implants were excluded. Clinical and device parameters were recorded before and after the CMR scan. A visual analysis of metal artifacts was performed for each sequence on a segmental basis, based on a 5-point artifact score. RESULTS: The vast majority of CMR scans (n = 255, 83%) were completely performed, while only 32 (10%) were interrupted soon after the first sequences and 22 (7%) were only partly acquired; CMR quality was non-diagnostic in 34 (11%) scans, poor (<1/3 sequences were diagnostic) in 25 (8%), or acceptable (1/3 to 2/3 sequences were diagnostic) in 40 (13%), while most scans (n = 201, 68%) were of overall good quality. No adverse event or device malfunctioning occurred, and only nonsignificant changes in device parameters were recorded. The most affected sequences were SSFP (median score 0.32 [interquartile range 0.07-0.91]), followed by GRE (0.18 [0.02-0.59]) and LGE (0.14 [0.02-0.55]). ICDs induced more artifacts (median score in SSFP images 0.87 [0.50-1.46]) than PMs (0.11 [0.03-0.28]) or ILRs (0.11 [0.00-0.56]). Moreover, most artifacts were located in the anterior, anteroseptal, anterolateral, and apical segments of the LV and in the outflow tract of the RV. CONCLUSIONS: CMR is a versatile imaging technique, with a high safety profile and overall good image quality even in patients with MR-conditional CIEDs. Several strategies are now available to optimize image quality, substantially enhancing overall diagnostic yield.

5.
Life (Basel) ; 13(9)2023 Aug 28.
Article in English | MEDLINE | ID: mdl-37763223

ABSTRACT

Intraprocedural stroke is a well-documented and feared potential risk of cardiovascular transcatheter procedures (TPs). Moreover, subclinical neurological events or covert central nervous system infarctions are concerns related to the development of dementia, future stroke, cognitive decline, and increased risk of mortality. Cerebral protection devices (CPDs) were developed to mitigate the risk of cardioembolic embolism during TPs. They are mechanical barriers designed to cover the ostium of the supra-aortic branches in the aortic arch, but newer devices are able to protect the descending aorta. CPDs have been mainly designed and tested to provide cerebral protection during transcatheter aortic valve replacement (TAVR), but their use in both Catheterization and Electrophysiology laboratories is rapidly increasing. CPDs have allowed us to perform procedures that were previously contraindicated due to high thromboembolic risk, such as in cases of intracardiac thrombosis identified at preprocedural assessment. However, several concerns related to their employment have to be defined. The selection of patients at high risk of thromboembolism is still a subjective choice of each center. The aim of this review is to update the evidence on the use of CPDs in either Cath labs or EP labs, providing an overview of their structural characteristics. Future perspectives focusing on their possible future employment are also discussed.

6.
Life (Basel) ; 13(8)2023 Jul 28.
Article in English | MEDLINE | ID: mdl-37629509

ABSTRACT

The difference between subcutaneous implantable cardioverter defibrillators (S-ICDs) and transvenous ICDs (TV-ICDs) concerns a whole extra thoracic implantation, including a defibrillator coil and pulse generator, without endovascular components. The improved safety profile has allowed the S-ICD to be rapidly taken up, especially among younger patients. Reports of its role in different cardiac diseases at high risk of SCD such as hypertrophic and arrhythmic cardiomyopathies, as well as channelopathies, is increasing. S-ICDs show comparable efficacy, reliability, and safety outcomes compared to TV-ICD. However, some technical issues (i.e., the inability to perform anti-bradycardia pacing) strongly limit the employment of S-ICDs. Therefore, it still remains only an alternative to the traditional ICD thus far. This review aims to provide a contemporary overview of the role of S-ICDs compared to TV-ICDs in clinical practice, including technical aspects regarding device manufacture and implantation techniques. Newer outlooks and future perspectives of S-ICDs are also brought up to date.

7.
J Clin Med ; 12(11)2023 Jun 05.
Article in English | MEDLINE | ID: mdl-37298059

ABSTRACT

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and predisposes patients to an increased risk of cardioembolic events (CE), such as ischemic stroke, TIA, or systemic embolism [...].

8.
J Clin Med ; 12(12)2023 Jun 17.
Article in English | MEDLINE | ID: mdl-37373791

ABSTRACT

BACKGROUND: The brain and heart are strictly linked and the electrical physiologies of these organs share common pathways and genes. Epilepsy patients have a higher prevalence of electrocardiogram (ECG) abnormalities compared to healthy people. Furthermore, the relationship between epilepsy, genetic arrhythmic diseases and sudden death is well known. The association between epilepsy and myocardial channelopathies, although already proposed, has not yet been fully demonstrated. The aim of this prospective observational study is to assess the role of the ECG after a seizure. MATERIALS AND METHODS: From September 2018 to August 2019, all patients admitted to the emergency department of San Raffaele Hospital with a seizure were enrolled in the study; for each patient, neurological, cardiological and ECG data were collected. The ECG was performed at the time of the admission (post-ictal ECG) and 48 h later (basal ECG) and analyzed by two blinded expert cardiologists looking for abnormalities known to indicate channelopathies or arrhythmic cardiomyopathies. In all patients with abnormal post-ictal ECG, next generation sequencing (NGS) analysis was performed. RESULTS: One hundred and seventeen patients were enrolled (females: 45, median age: 48 ± 12 years). There were 52 abnormal post-ictal ECGs and 28 abnormal basal ECGs. All patients with an abnormal basal ECG also had an abnormal post-ictal ECG. In abnormal post-ictal ECG, a Brugada ECG pattern (BEP) was found in eight patients (of which two had BEP type I) and confirmed in two basal ECGs (of which zero had BEP type I). An abnormal QTc interval was identified in 20 patients (17%), an early repolarization pattern was found in 4 patients (3%) and right precordial abnormalities were found in 5 patients (4%). Any kind modification of post-ictal ECG was significantly more pronounced in comparison with an ECG recorded far from the seizure (p = 0.003). A 10:1 higher prevalence of a BEP of any type (particularly in post-ictal ECG, p = 0.04) was found in our population compared to general population. In three patients with post-ictal ECG alterations diagnostic for myocardial channelopathy (BrS and ERP), not confirmed at basal ECG, a pathogenic gene variant was identified (KCNJ8, PKP2 and TRMP4). CONCLUSION: The 12-lead ECG after an epileptic seizure may show disease-related alterations otherwise concealed in a population at a higher incidence of sudden death and channelopathies. Post-ictal BEP incidence was higher in cases of nocturnal seizure.

9.
J Clin Med ; 12(9)2023 May 02.
Article in English | MEDLINE | ID: mdl-37176691

ABSTRACT

Implantable cardiac pacemakers have greatly evolved during the few past years, focusing on newer modalities of physiologic cardiac pacing [...].

10.
Nutr Metab Cardiovasc Dis ; 33(7): 1323-1329, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37248142

ABSTRACT

BACKGROUND AND AIMS: Interest in the role of atrial substrate in maintaining Atrial Fibrillation (AF) is growing. Fibrosis is the culprit in the electrical derangement of the myocytes. Many cardiovascular risk factors are known to be linked to atrial scarring; among them Uric Acid (UA) is emerging. The purpose of our study is to find whether UA is associated with Left Atrium (LA) with pathological substrate. METHODS AND RESULTS: 81 patients who underwent radiofrequency transcatheter ablation for nonvalvular AF at the cardiological department of the Niguarda Hospital were enrolled in an observational, cross-sectional, single-center study. UA levels were analysed before the procedure. High density electroanatomic mapping of the LA was performed and patients were divided according to the presence or not of areas of pathological substrate (bipolar voltage <0.5 mV in sinus rhythm). 19 patients showed a LA with pathological substrate. These subjects showed a significant higher prevalence of persistent phenotype of AF (84.2 vs. 25.8%, p < 0.001). UA levels were significantly higher in the group of patients with LA with pathological substrate (6.8 ± 1.9 vs 5.3 ± 1.4 mg/dL, p < 0.001) as well as the prevalence of hyperuricemia (26.5 vs. 6.5%, p = 0.021). The association between uric acid LA with pathological substrate remains significant even after correction for confounding factors (age, left ventricular dysfunction, valvular disease, arrythmia phenotype and furosemide use) and also when the ratio UA/creatinine was evaluated. CONCLUSIONS: In a population of patients who underwent AF ablation, higher UA levels were significantly associated with pathological LA substrate at electro-anatomical mapping.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Uric Acid , Cross-Sectional Studies , Heart Atria/diagnostic imaging , Heart Atria/pathology , Fibrosis
11.
Clin Cardiol ; 41(4): 494-501, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29663442

ABSTRACT

BACKGROUND: Late gadolinium enhancement (LGE) assessed with cardiovascular magnetic resonance (CMR) correlates with ventricular arrhythmias and survival in patients with structural heart disease. Whether some LGE characteristics may specifically improve prediction of arrhythmic outcomes is unknown. HYPOTHESIS: We sought to evaluate scar characteristics assessed with CMR to predict implantable cardioverter-defibrillator (ICD) interventions in dilated cardiomyopathy of different etiology. METHODS: 96 consecutive patients evaluated with CMR received an ICD. Biventricular volumes, ejection fraction, and myocardial LGE were evaluated. LGE was defined as "complex" (Cx-LGE) in presence of ≥1 of the following: ischemic pattern, involving ≥2 different coronary territories; epicardial pattern; global endocardial pattern; and presence of ≥2 different patterns. The primary endpoint was occurrence of any appropriate ICD intervention. A composite secondary endpoint of cardiovascular death, cardiac transplantation, or ventricular assist device implantation was also considered. RESULTS: During a median follow-up of 75 months, 30 and 25 patients reached the primary and secondary endpoints, respectively. Cx-LGE was correlated with a worse primary endpoint survival (log-rank P < 0.001). Cx-LGE and right ventricular end-diastolic volume were independently associated with the primary endpoint (HR: 3.22, 95% CI: 1.56-6.65, P = 0.002; and HR: 1.06, 95% CI: 1.00-1.12, P = 0.045, respectively), but not with the secondary endpoint. CONCLUSIONS: Cx-LGE identified at CMR imaging seems promising as an independent and specific prognostic factor of ventricular arrhythmias requiring ICD therapy in dilated cardiomyopathy of different etiologies.


Subject(s)
Arrhythmias, Cardiac/diagnostic imaging , Cardiomyopathy, Dilated/diagnostic imaging , Cicatrix/diagnostic imaging , Clinical Decision-Making , Defibrillators, Implantable , Electric Countershock/instrumentation , Magnetic Resonance Imaging, Cine , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/therapy , Cardiomyopathy, Dilated/etiology , Cardiomyopathy, Dilated/physiopathology , Cardiomyopathy, Dilated/therapy , Cicatrix/etiology , Cicatrix/physiopathology , Cicatrix/therapy , Contrast Media/administration & dosage , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Disease Progression , Disease-Free Survival , Female , Gadolinium DTPA/administration & dosage , Humans , Male , Middle Aged , Patient Selection , Predictive Value of Tests , Recovery of Function , Registries , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
12.
J Arrhythm ; 33(5): 494-496, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29021856

ABSTRACT

In patients with left ventricular assist device (LVAD), a minority of post-operative ventricular tachycardias (VTs) is caused by contact between the inflow cannula and the endocardium. Currently, electrophysiologic characteristics and pathologic features of this condition are lacking. We report on a case of a successfully ablated mechanical VT. After VT recurrence, heart transplantation took place. Pathologic observations were consistent with direct tissue injury and inflammation, eventually contributing to persisting arrhythmias. Radiofrequency catheter ablation can be a safe and effective option to treat arrhythmias caused by inflow cannula interference in the short term, although a high recurrence rate is expected.

13.
J Cardiovasc Med (Hagerstown) ; 17(4): 291-8, 2016 Apr.
Article in English | MEDLINE | ID: mdl-25222077

ABSTRACT

AIMS: Cardiac resynchronization therapy (CRT) is a well established therapy in heart failure patients who are on optimal medical therapy and have reduced left ventricular ejection fraction (LVEF) and wide QRS complexes. Although women and patients with nonischemic cardiomyopathy are under-represented in CRT trials and registries, there is evidence that these two groups of patients can benefit more from CRT. The aim of our analysis was to investigate the impact of female sex on mortality in a population that included a high percentage of patients (61%) with nonischemic cardiomyopathy. METHODS: We analyzed data on 507 consecutive patients (20% women) who received CRT at two Italian Heart Transplant centers and were followed up for a maximum of 48 months. RESULTS: After multivariate adjustment, women showed a trend toward better survival with regard to all-cause mortality [hazard ratio (HR) 0.32, confidence interval (CI) 0.10-1.04; P = 0.059]. However, this benefit was limited to nonischemic patients with regard to all-cause mortality (HR 0.20, CI 0.05-0.87, P = 0.032) and cardiovascular mortality (HR 0.14, CI 0.02-1.05, P = 0.056). CONCLUSION: Female CRT recipients, at mid-term, have a favorable prognosis than male patients and this benefit appears to be more evident in nonischemic patients. Thus, we strongly believe that the apparent under-utilization of CRT in females is an anomaly that should be corrected.


Subject(s)
Cardiac Resynchronization Therapy/methods , Cardiomyopathies/therapy , Ventricular Remodeling/physiology , Aged , Cardiomyopathies/diagnosis , Cardiomyopathies/mortality , Cardiomyopathies/physiopathology , Defibrillators, Implantable , Female , Follow-Up Studies , Humans , Italy/epidemiology , Kaplan-Meier Estimate , Male , Middle Aged , Prognosis , Sex Factors , Stroke Volume/physiology , Treatment Outcome
14.
J Arrhythm ; 31(6): 401-5, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26702324

ABSTRACT

A 77-year-old man with ischemic cardiomyopathy and a cardiac resynchronization therapy-defibrillator (CRT-D) device came to our attention due to incessant ventricular tachycardia and multiple implantable cardioverter defibrillator (ICD) shocks. An electrocardiogram showed non-sustained monomorphic ventricular tachycardias (NSVTs) constantly occurring after each biventricular stimulation. During an electrophysiological study, NSVTs reproducibly recurred only after right ventricular (RV) pacing; LV pacing did not induce any NSVTs. The activation map was consistent with a localized reentry at the interventricular septum, and a double exit; at the LV exit site, a single radiofrequency energy application immediately interrupted the occurrence of the NSVTs. Current evidence supports LV pacing to be pro-arrhythmogenic in few CRT patients. This unusual case shows that RV pacing during CRT could produce frequent ventricular arrhythmias and arrhythmic storm. Catheter ablation can be considered an effective therapeutic option, especially when CRT maintenance is highly advisable.

15.
Int J Cardiol ; 172(1): 64-71, 2014 Mar 01.
Article in English | MEDLINE | ID: mdl-24456869

ABSTRACT

BACKGROUND: Reverse remodeling and increased LVEF after CRT correlate with survival and heart failure hospitalizations, but their relationship with the risk of SCD is unclear. We aimed to evaluate whether exceeding a threshold value of 35% for left ventricular ejection fraction (LVEF) 1 year after cardiac resynchronization therapy (CRT) predicts survival and freedom from sudden cardiac death (SCD). METHODS: 330 patients who survived ≥ 6 months after CRT (males 80%, age 62 ± 11 years) were grouped according to 1-year LVEF ≤ 35% (Group 1, n=187, 57%) or >35% (Group 2, n=143, 43%). According to changes vs. baseline (reduction of left end-systolic volume [LVESV] ≥ 10% or increase of LVEF% > 10 units), patients were also classified as echocardiographic (Echo) non-responders (Group A, n=152, 46%) or responders (Group B, n=178, 54%). RESULTS: At baseline, LVESV volume was larger and LVEF was lower in Group 1 vs. Group 2 (p<0.001). After 1 year, echocardiographic improvement was greater in Group 2 vs. Group 1 (p<0.001 for changes in both LVESV and LVEF). Over a median follow-up of 49 months, 47 patients (14%) died, 36 in Group 1 vs. 11 in Group 2 (19% vs. 8%, p=0.004). A significantly higher rate of freedom from all-cause mortality (p=0.002), cardiovascular mortality (p<0.001) and SCD (p<0.001) was observed in Group 2. Multivariate analysis demonstrated that only 1-year LVEF >35% was associated with freedom from SCD/VF. CONCLUSIONS: LVEF >35% after 1 year of CRT characterizes a favorable long-term outcome, with a very low risk for SCD.


Subject(s)
Cardiac Resynchronization Therapy/mortality , Death, Sudden, Cardiac/prevention & control , Heart Failure/mortality , Stroke Volume , Ventricular Function, Left , Aged , Death, Sudden, Cardiac/epidemiology , Disease-Free Survival , Echocardiography , Female , Follow-Up Studies , Heart Failure/diagnostic imaging , Humans , Male , Middle Aged , Multivariate Analysis , Predictive Value of Tests , Prognosis , Risk Factors
16.
Europace ; 16(6): 914-22, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24158255

ABSTRACT

AIMS: To assess the diagnostic yield of new external loop recorders (ELRs) in patients with history of syncope, pre-syncope, and sustained palpitations. METHODS AND RESULTS: Since 2005, we have established a registry including patients who consecutively received ELR monitoring for unexplained syncope or pre-syncope/palpitations. The registry included 307 patients (61% females, age 58 ± 19 years, range 8-94 years) monitored by high-capacity memory ELR of two subsequent generations: SpiderFlash-A(®) (SFA(®), Sorin CRM), storing two-lead electrocardiogram (ECG) patient-activated recordings by loop-recording technique (191 patients, 54 patients with syncope, years 2005-09), and SpiderFlash-T(®) (SFT(®)), adding auto-trigger detection for pauses, bradycardia, and supraventricular/ventricular arrhythmias (116 patients, 38 patients with syncope, years 2009-12). All the patients previously underwent routine workup for syncope or palpitation, including one or more 24 h Holter, not conclusive for diagnosis. Mean monitoring duration was 24.1 ± 8.9 days. Among 215 patients with palpitations, a conclusive diagnosis was obtained in 184 patients (86% diagnostic yield for palpitation). Among 92 patients with syncope, a conclusive diagnosis was obtained in 16 patients (17% clinical diagnostic yield for syncope), with recording during syncope of significant arrhythmias in 9 patients, and sinus rhythm in 7 patients. Furthermore, asymptomatic arrhythmias were de novo detected in 12 patients (13%), mainly by auto-trigger detection, suggesting an arrhythmic origin of the syncope. CONCLUSIONS: The diagnostic yield of ELR in patients with syncope, pre-syncope, or palpitation of unknown origin after routine workup was similar to implantable loop recorder (ILR) within the same timeframe, therefore, ELR could be considered for patients candidate for long-term ECG monitoring, stepwise before ILR.


Subject(s)
Arrhythmias, Cardiac/diagnosis , Electrocardiography, Ambulatory/instrumentation , Syncope/diagnosis , Adolescent , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac/epidemiology , Causality , Child , Comorbidity , Diagnosis, Differential , Electrocardiography, Ambulatory/statistics & numerical data , Equipment Design , Equipment Failure Analysis , Female , Humans , Incidence , Italy/epidemiology , Male , Middle Aged , Registries , Reproducibility of Results , Sensitivity and Specificity , Syncope/epidemiology , Young Adult
17.
G Ital Cardiol (Rome) ; 13(10 Suppl 2): 36S-40S, 2012 Oct.
Article in Italian | MEDLINE | ID: mdl-23096373

ABSTRACT

A large number of studies have demonstrated that remote control of implantable devices (home monitoring, HM) is beneficial for patients, as it allows strict and tailored controls with earlier identification of potential problems, by avoiding unnecessary visits. HM is also beneficial for hospitals, as it progressively reduces the resources necessary for routine controls and contributes to a better management of critical patients. According to current European and Italian guidelines, HM can replace standard ambulatory monitoring, thereby decreasing the number of outpatient visits for each individual patient (it is possible to schedule a comprehensive clinical evaluation at 1 year rather than every 6-8 months, while performing controls at 1 and 3 months by remote transmission). At present, however, reimbursement of HM services is not covered by the National Health System and, as a consequence, cannot be performed as an institutional activity within the hospital. In addition, many critical issues remain to be resolved before the HM system can be fully implemented into daily clinical management, particularly in patients with heart failure at higher risk for sudden cardiac death.


Subject(s)
Defibrillators, Implantable , Heart Arrest/therapy , Monitoring, Ambulatory , Telemedicine , Humans
18.
Int J Cardiol ; 126(2): 190-5, 2008 May 23.
Article in English | MEDLINE | ID: mdl-17498824

ABSTRACT

OBJECTIVE: To investigate the clinical relevance of l-thyroxine (l-T(4)) substitution therapy in borderline hypothyroidism. DESIGN: To assess whether and to what extent administration of l-T(4) is able to modify systolic and diastolic function in patients with subclinical hypothyroidism and in subjects with autoimmune thyroiditis and normal serum TSH. METHODS: We studied 26 patients with classical Hashimoto's thyroiditis [18 with increased serum TSH (>3 mU/ml - Group A), and 8 with normal serum TSH (<3 mU/ml) - Group B]; a third group (C) included 13 healthy controls. All subjects underwent Pulsed Wave Tissue Doppler Imaging (PWTDI) to accurately quantify the global and regional left ventricular function. RESULTS: In both groups A and B we confirmed a significant impairment of systolic ejection (p<0.001 and p<0.05, respectively), a delay in diastolic relaxation (p<0.001 and p<0.05, respectively) and a decrease in the compliance to the ventricular filling (p<0.05). Administration of 50 microg/day of l-T(4) produced a progressive reduction of serum TSH (within the normal range) and normalization of all PWTDI parameters, which began after 6 months and finished after 12 months. CONCLUSION: Our data confirm previous evidence that subclinical hypothyroidism is associated with a cardiac dysfunction, even when this is very mild (i.e. with serum TSH still comprised in the normal range), and show that these abnormalities are reversible with l-T(4) replacement therapy.


Subject(s)
Cardiovascular Diseases/drug therapy , Hypothyroidism/drug therapy , Thyroxine/administration & dosage , Adult , Cardiovascular Diseases/complications , Cardiovascular Diseases/diagnostic imaging , Female , Humans , Hypothyroidism/complications , Hypothyroidism/diagnostic imaging , Male , Middle Aged , Radiography
19.
Eur J Endocrinol ; 152(4): 527-33, 2005 Apr.
Article in English | MEDLINE | ID: mdl-15817907

ABSTRACT

OBJECTIVE: In subclinical hypothyroidism (SH), impaired diastolic function has been documented at rest and on effort, while systolic dysfunction has only been assessed on effort. DESIGN: The aim of the present study was: (a) to further assess systolic function at rest in SH; and (b) to ascertain whether cardiac dysfunction could precede TSH increase in euthyroid patients with a high risk of developing SH. METHODS: We studied 32 patients with classical Hashimoto's thyroiditis (22 with increased serum TSH (> 3 mU/ml - group A), and 10 with normal serum TSH (< 3 mU/ml - group B)); a third group (C), which included 13 healthy controls. All subjects underwent pulsed wave tissue Doppler imaging (PWTDI) to accurately quantify the global and regional left ventricular function. RESULTS: When compared with group C, PWTDI indices showed that in both groups A and B there was a significant impairment of systolic ejection (P < 0.001 and P < 0.05, respectively), a delay in diastolic relaxation (P < 0.001 and P < 0.05, respectively) and a decrease in the compliance to the ventricular filling (P < 0.05). Several significant correlations were found between PWTDI parameters and serum-free T(3) and T(4) and TSH concentrations. CONCLUSION: PWTDI is a sensitive technique that allows detection of both diastolic and systolic abnormalities, not only in patients with SH, but also in euthyroid subjects with a high risk of developing thyroid failure. Futhermore, the significant correlations of several PWTDI indices with serum FT(3) and TSH concentrations strongly support the concept of a continuum spectrum of a slight thyroid failure in autoimmune thyroiditis extending to subjects with serum TSH still within the normal range.


Subject(s)
Echocardiography, Doppler, Pulsed , Heart/physiopathology , Hypothyroidism/physiopathology , Adult , Diastole , Female , Humans , Male , Middle Aged , Systole , Thyroid Gland/physiopathology , Thyrotropin/blood , Thyroxine/blood , Triiodothyronine/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...