Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Heliyon ; 10(5): e27263, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38463884

ABSTRACT

Compressors are a significant source of noise in various industries. Silencers can be utilized to mitigate this noise. This study aims to design and construct an expansion silencer that can effectively reduce the pulsating noise produced by a reciprocating compressor. This study employed a model-experimental approach to investigate the performance of four different sizes of expansion silencers in controlling the pulsating noise in the suction part of the compressor. Initially, the silencers' sound transmission loss and pressure loss were simulated using the finite element method with COMSOL software. Subsequently, the sound transmission loss of the silencers was measured according to the E261109 standard using an impedance tube. Finally, the pressure loss of the silencers was measured using a Pitot tube upstream and downstream of the silencer at various flow rates. The results of the modeling showed that increasing the diameter of the silencer leads to an increase in transmission loss at all frequencies. Additionally, raising the length of the silencer only increased the number of sound transmission loss peaks in the frequency bandwidth without significant change in sound transmission loss. Furthermore, the results of the experimental measurements with an impedance tube revealed that increasing the diameter results in increased transmission loss, while increasing the silencer length leads to an increase in the number of transmission loss peaks without altering the transmission loss. Moreover, the modeling and experimental pressure loss results indicated that increasing the diameter of the expansion chamber causes an increase in pressure loss, while increasing the length of the expansion chamber results in a minor change in pressure loss. Finally, the research results showed relatively good agreement between modeling and experimental outcomes.

2.
Electron Physician ; 9(10): 5525-5530, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29238493

ABSTRACT

BACKGROUND AND AIM: Test of maximal oxygen consumption is the gold standard for measuring cardio-pulmonary fitness. This study aimed to determine correlation of Gerkin, Queen's College, George, and Jackson methods in estimating maximal oxygen consumption, and demographic factors affecting maximal oxygen consumption. METHODS: This descriptive cross-sectional study was conducted in a census of medical emergency students (n=57) in Qazvin University of Medical Sciences in 2016. The subjects firstly completed the General Health Questionnaire (PAR-Q) and demographic characteristics. Then eligible subjects were assessed using exercise tests of Gerkin treadmill, Queen's College steps and non-exercise George, and Jackson. Data analysis was carried out using independent t-test, one way analysis of variance and Pearson correlation in the SPSS software. RESULTS: The mean age of participants was 21.69±4.99 years. The mean of maximal oxygen consumption using Gerkin, Queen's College, George, and Jackson tests was 4.17, 3.36, 3.64, 3.63 liters per minute, respectively. Pearson statistical test showed a significant correlation among fours tests. George and Jackson tests had the greatest correlation (r=0.85, p>0.001). Results of tests of one-way analysis of variance and t-test showed a significant relationship between independent variable of weight and height in four tests, and dependent variable of maximal oxygen consumption. Also, there was a significant relationship between variable of body mass index in two tests of Gerkin and Queen's College and variable of exercise hours per week with the George and Jackson tests (p>0.001). CONCLUSION: Given the obtained correlation, these tests have the potential to replace each other as necessary, so that the non-exercise Jackson test can be used instead of the Gerkin test.

3.
Electron Physician ; 9(3): 4020-4026, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28461880

ABSTRACT

INTRODUCTION: Maximum oxygen consumption shows the maximum oxygen rate of muscle oxygenation that is acceptable in many cases, to measure the fitness between person and the desired job. Given that medical emergencies are important, and difficult jobs in emergency situations require people with high physical ability and readiness for the job, the aim of this study was to evaluate the maximum oxygen consumption, to determine the ability of work type among students of medical emergencies in Qazvin in 2016. METHODS: This study was a descriptive - analytical, and in cross-sectional type conducted among 36 volunteer students of medical emergencies in Qazvin in 2016. After necessary coordination for the implementation of the study, participants completed health questionnaires and demographic characteristics and then the participants were evaluated with step tests of American College of Sport Medicine (ACSM). Data analysis was done by SPSS version 18 and U-Mann-Whitney tests, Kruskal-Wallis and Pearson correlation coefficient. RESULTS: Average of maximum oxygen consumption of the participants was estimated 3.15±0.50 liters per minute. 91.7% of medical emergencies students were selected as appropriate in terms of maximum oxygen consumption and thus had the ability to do heavy and too heavy work. Average of maximum oxygen consumption evaluated by the U-Mann-Whitney test and Kruskal-Wallis, had significant relationship with age (p<0.05) and weight groups (p<0.001). There was a significant positive correlation between maximum oxygen consumption with weight and body mass index (p<0.001). CONCLUSION: The results of this study showed that demographic variables of weight and body mass index are the factors influencing the determination of maximum oxygen consumption, as most of the students had the ability to do heavy, and too heavy work. Therefore, people with ability to do average work are not suitable for medical emergency tasks.

SELECTION OF CITATIONS
SEARCH DETAIL
...