J Arthroplasty ; 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38830428

ABSTRACT

BACKGROUND: The incidence of total joint arthroplasty is increasing, with added emphasis on shifting care towards outpatient surgery. This has demonstrated improvements in costs and care; however, safety must be prioritized. Published assessment tools highlight candidates for outpatient surgery; however, they often do not define patients who have a worse prognosis. Limited healthcare resources occasionally force patients to convert to outpatient surgery or risk cancellation, creating a dilemma for both patients and surgeons. We evaluated the short-term (90-day) outcomes of patients converted from planned inpatient admission to same-day discharge on day of surgery outpatients and sought to identify any groups at risk, who may not be appropriate for this conversion. METHODS: We identified all patients undergoing planned inpatient total hip or knee arthroplasty at a tertiary academic medical center over a two-year period. We included patients discharged the day of surgery for analysis, excluding revision procedures and those performed for fracture care. A manual chart review identified demographic factors and primary outcome measures; including re-operation, re-admission, and emergency room visits within a 90-day post-operative period. RESULTS: We identified a total of 80 patients who converted from inpatient to outpatient surgery over a two-year interval. Over the first 90 days post-operatively four (5%) patients were readmitted: two (2.5%) for medical complications and two (2.5%) for re-operation. There were two (2.5%) re-operations; one (1.25%) for manipulation under anesthesia, and one (1.25%) for periprosthetic joint infection. There were five (6.3%) wound complications; however, only one (1.25%) required surgical intervention. A total of five (6.3%) patients returned to an emergency department, leading to a single (1.25%) hospital readmission. CONCLUSIONS: Hospital and healthcare resources are occasionally limited to the extent that patients must convert to outpatient surgery or risk cancellation. At our institution, the same-day conversion of planned inpatient hip and knee arthroplasty patients to outpatient surgery was safe and did not increase short-term clinical outcomes or complications.

2.
J Arthroplasty ; 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38830433

ABSTRACT

INTRODUCTION: The aim of the study was to analyze the Canadian Cardiovascular Society (CCS) guidelines for routine postoperative troponin testing after elective total hip arthroplasty (THA) to reduce the mortality rate resulting from myocardial injury. The purpose of this study was to assess the prognostic relevance of implementing these guidelines to minimize cardiac events in patients undergoing elective THA. METHODS: Patients who underwent THA surgery in 2020 were included in the study. The inclusion criteria were elective THA patients aged ≥ 45 years, while emergency, revision, and simultaneous bilateral THA surgeries were excluded. The patients were categorized into four groups based on the CCS guidelines. RESULTS: The study included 669 patients who had an average age of 67 years. There were forty-three patients (6.4%), who experienced a rise in troponin levels ≥ 30 ng/L and developed myocardial injury after noncardiac surgery (MINS). Among these patients, eight developed cardiac complications, and one experienced a serious cardiac event that resulted in death. Notably, there was a significant increase in the length of hospital stay for patients who received the postoperative screening protocol. CONCLUSION: The implementation of the CCS guidelines for routine postoperative troponin testing in elective THA surgery did not significantly decrease the rate of cardiac events or mortality.

3.
J Arthroplasty ; 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38848790

ABSTRACT

PURPOSE: Periprosthetic joint infection (PJI) continues to be one of the leading causes of failure following total hip arthroplasty (THA). The objectives of the study were to: 1) determine the minimum 2-year infection-free survivorship of two-stage revision THA; 2) determine the causative organisms for repeat two-stage revision THA; and 3) characterize the results of failed two-stage revisions and evaluate patient-reported outcome measures (PROMs). METHODS: A retrospective chart review was completed for patients who underwent two-stage revision THA for PJI. Prospective data was collected on each patient, including demographics, causative organisms, complications, and type of reoperation. The PROMs, including Harris Hip Score (HHS), 12-item Short-Form Health Survey (SF-12), and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were obtained prior to two-stage revision THA surgery and annually as part of standard clinical and radiographic follow-up. RESULTS: A total of 328 patients who underwent a two-stage revision THA for a PJI were included in the study (mean age 67 years (range, 28 to 90), mean BMI of 30.6 (range, 15 to 57). The overall infection-free survivorship for two-stage revision THA was 73.8% at a minimum of 2 years (range, 2 to 20). Overall, 194 (59.1%) patients who had successful infection eradication underwent a two-revision THA only. The most common single organisms infected were Staphylococcus aureus (12.5%) and Staphylococcus epidermidis (11%). Higher reoperation rates were found in cases with MRSA and polymicrobial infections. All PROMs showed statistical improvement from pre-operatively to the latest follow-up appointment. CONCLUSIONS: Two-stage revision THA is associated with a good success rate in the treatment of PJIs at mid- to long-term follow-up. Polymicrobial and MRSA infections are poor prognostic factors, making the eradication of infection more difficult. The management of periprosthetic joint infections continues to be one of the most important orthopaedic challenges to treat.

4.
J Arthroplasty ; 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38626864

ABSTRACT

BACKGROUND: Despite the growing popularity of cementless total knee arthroplasty (TKA) in younger patients, the outcomes are unclear in the elderly population. We aimed to compare the clinical outcomes and survivorship of cementless TKA between different age groups. METHODS: Utilizing our prospectively collected institutional database, we retrospectively reviewed all patients undergoing primary cementless TKAs at a tertiary care institute. We identified 347 TKA, which were divided into 3 groups based on age at the time of surgery. Group A was ≤ 60 years, Group B was 60 to ≤ 70 years, and Group C was > 70 years. We compared clinical outcomes (Knee Society Clinical Rating System [KSCRS], Western Ontario and McMaster University Osteoarthritis Index [WOMAC], and Veterans Rand 12 Item Health Survey [VR-12]) and survivorship between the groups. RESULTS: At final follow-up, range of motion, KSCRS, WOMAC, and VR-12 physical score were comparable (P > .05). The VR-12 Mental score was higher in Group B and Group C than in Group A (P = .003). Compared to preoperative scores, the change in KSCRS, WOMAC, and VR-12 physical and mental scores was comparable at the final follow-up (P > .05). No patient underwent revision for aseptic loosening. CONCLUSIONS: There were no cases of revision surgery for aseptic loosening in our cohort of 347 cementless TKAs. Patients > 70 years of age undergoing cementless TKA can achieve clinical scores equivalent to those of younger patients at short term (2-year) follow-up. Longer-term survivorship is still required, but based on early data, cementless TKA can be a safe option for older patients.

5.
J Arthroplasty ; 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38522799

ABSTRACT

BACKGROUND: Bicruciate-stabilized (BCS) total knee arthroplasty (TKA) designs attempt to approximate natural knee mechanics. Multiple surgical techniques, including gap balancing (GB) and measured resection (MR), have been developed to provide optimal implant positioning and soft-tissue balance. The goal of this study was to determine the effect of surgical technique on BCS TKA contact kinematics. Secondary goals included investigating the change of kinematics over time and comparing BCS TKA kinematics to a posterior-stabilized (PS) design. METHODS: The study included the BCS-GB, BCS-MR, and PS-MR groups. The BCS-GB and BCS-MR groups underwent weight-bearing radiostereometric analysis for multiple knee flexion angles at 3 months and 1 year postoperatively, whereas the PS-MR group was imaged at 1 year postoperatively. The medial and lateral contact kinematics were determined from implant poses. RESULTS: There were no differences in BCS TKA kinematics between the GB and MR techniques. There were differences in the mid-flexion ranges when comparing the 3-month and 1-year kinematics of the BCS design; however, they were less than 1.5 mm. Differences existed between the kinematics of the BCS and PS designs at all flexion angles for the medial condyle (P < .0006) and at 0° of flexion on the lateral condyle (P < .0001). CONCLUSIONS: Contact kinematics for a BCS design were similar for both surgical techniques, suggesting both are appropriate for this design. Small, likely clinically insignificant differences were found between 3-month and 1-year kinematics. The BCS TKA kinematics differed from the PS design; however, it is unclear whether these differences improve clinical outcomes.

6.
J Arthroplasty ; 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38521249

ABSTRACT

BACKGROUND: Modular titanium fluted tapered (TFT) stems have demonstrated excellent clinical success for femoral revision total hip arthroplasty (THA) surgery. This study reports the short-term outcomes of a novel modern monoblock TFT stem used for revision and complex primary THA with a minimum of 2 years of follow-up. METHODS: We identified 126 patients who received a single monoblock TFT stem: 26 patients for complex THA (failed fracture fixation) and 100 patients for revision THA. The reasons for revision THA included 40 for previous periprosthetic joint infection, 42 for aseptic loosening, 9 for trunnionosis, and 9 for periprosthetic fractures. The Paprosky grading for femoral bone loss at the time of surgery and the measured subsidence of femoral stems at 3-month follow-up were determined. We evaluated the number and indications for reoperations. RESULTS: The mean time from surgery was 3.9 years (range, 2.0 to 6.9). A paired t-test analysis showed significant improvement from preoperative versus postoperative clinical outcome scores (P < .001) for Harris Hip Score (38.76 ± 15.24 versus 83.42 ± 15.38), Western Ontario and McMaster Universities Arthritis Index (45.6 ± 19.0 versus 69.9 ± 21.3), Veterans RAND 12 Item Health Survey Physical component (31.7 ± 8.1 versus 37.8 ± 11.3), and Veterans RAND 12 Item Health Survey Mental component (48.2 ± 12.2 versus 51.6 ± 12.5). The Paprosky grading for femoral bone loss was Grade 1 (3.9%), Grade 2 (35.7%), Grade 3A (47.6%), Grade 3B (11.1%), and Grade 4 (1.6%) cases. There were 18 reoperations (14.7%), with 13 for periprosthetic joint infection (7 treated with implant retention and 6 treated with a 2-stage revision), 4 for instability, and 1 for acetabular aseptic loosening. There were no aseptic failures of the stem. CONCLUSIONS: This novel modern monoblock TFT stem provided reliable femoral fixation and has increasingly supplanted the use of modular TFT stems for complex primary and revision surgery in our institution.

7.
Can J Surg ; 67(2): E85-E90, 2024.
Article in English | MEDLINE | ID: mdl-38453351

ABSTRACT

BACKGROUND: Interest in cementless total knee arthroplasty (TKA) has increased with advancement of biomaterials and implant design and associated improved longevity. We sought to evaluate the gap patterns and radiolucent zones radiographically for 2 newer-generation cementless TKA designs. METHODS: We retrospectively reviewed our single-institution database between January 2017 and December 2019. We identified patients with a porous keeled tibia base-plate with 4-bullet cruciform spikes and peri-apatite coated femoral component (study group 1) and patients who received a cementless porous coated femoral component and rotating platform tibia baseplate with 4 peripheral porous coated pegs around a central cone (study group 2). We identified gap patterns at 6 weeks and at 1 year or more postoperatively on radiographs, noting indications for reoperation. RESULTS: We identified 228 patients in study group 1 and 41 patients in study group 2. At 1-year follow-up, we found evidence of resolved femoral gaps in 52 (72.2%) of 72 patients in study group 1 and 10 (58.8%) of 17 patients in study group 2 (p = 0.124). We identified 27 (84.3%) of 32 patients in study group 1 and 7 (70.0%) of 10 patients in study group 2 with resolved tibia gaps (p = 0.313). After 1 year, there were significantly more Zone 3a femoral zonal radiolucent gaps (p = 0.001) and Zone 8 tibia zonal radiolucent gaps (p = 0.002) in study group 2 than in study group 1. There were 4 reoperations for study group 1 and 0 reoperations for study group 2. CONCLUSION: The modern cementless TKA systems have varied gap patterns in postoperative radiographs, which may be attributed to the implant design. Most radiolucent gaps resolve radiographically on follow-up.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Follow-Up Studies , Retrospective Studies , Femur/diagnostic imaging , Femur/surgery , Reoperation , Prosthesis Design , Treatment Outcome , Prosthesis Failure
8.
Bone Jt Open ; 5(1): 20-27, 2024 Jan 17.
Article in English | MEDLINE | ID: mdl-38229582

ABSTRACT

Aims: A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis. Methods: Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits. Results: The patient cohort mean age was 66 years (SD seven years), 59% were female, and the mean BMI was 32 kg/m2 (SD 6 kg/m2). Mean two-year subsidence of the EF-TKA was 0.056 mm (95% confidence interval (CI) 0.025 to 0.086) versus 0.006 mm (95% CI -0.029 to 0.040) for the Std-TKA, and the two-year maximum total point motion (MTPM) was 0.285 mm (95% upper confidence limit (UCL) ≤ 0.363) versus 0.346 mm (95% UCL ≤ 0.432), respectively, for a mean difference of -0.061 mm (95% CI -0.196 to 0.074). Inducible displacement also did not differ between groups. The MTPMs between 12 and 24 months for each group was below the published threshold of 0.2 mm for predicting early aseptic loosening (p < 0.001 and p = 0.001, respectively). Conclusion: Both the enhanced fixation and the standard tibial implant design showed fixation with a predicted low risk of long-term aseptic loosening.

9.
Hip Int ; 34(1): 42-48, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37016808

ABSTRACT

BACKGROUND: Early cup migration after total hip arthroplasty (THA) is correlated to late revision due to aseptic loosening. However, the use of screws for increased cup stability remains unclear and debated. The purpose of this study is to assess acetabular migration between cups fixated with and without the use of screws. METHODS: Patients underwent primary THA using either a direct anterior (DA) or a direct lateral (DL) approach. The DA surgeon routinely supplemented cup fixation with 1 or 2 screws while the DL surgeon used no screws. At 7 follow-up visits up to 2 years post operation, patients underwent radiostereometric analysis (RSA) imaging for implant migration tracking. The primary outcome was defined as proximal cup migration measured with model-based RSA. RESULTS: 68 patients were assessed up to 2 years post operation, n = 43 received screws and n = 25 did not. The use of screws had a significant effect on cup migration (p = 0.018). From 2 weeks to 2 years post operation, the total mean migration was 0.403 ± 0.681 mm and 0.129 ± 0.272 mm (p = 0.319) for cups with and without screws, respectively. The number of screws used also had a significant impact, with cups fixated with 1 screw migrating more than cups fixated with 2 (p = 0.013, mean difference 0.712 mm). CONCLUSIONS: Acetabular cups fixated with only 1 screw resulted in greater migration than cups with no screws or 2 screws, though the mean magnitude was well under the 1.0 mm threshold for unacceptable migration. However, 3 of the 24 patients who received only 1 screw exceeded the 1.0 mm threshold for unacceptable migration. Ultimately, the results of this study show that the use of 2 screws to supplement cup fixation can provide good implant stability that is equivalent to a secure press-fit component with no screws.Clinical trial registration: ClinicalTrials.gov (NCT03558217).


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Acetabulum/diagnostic imaging , Acetabulum/surgery , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Bone Screws , Follow-Up Studies , Prosthesis Design , Prosthesis Failure , Radiostereometric Analysis
10.
J Arthroplasty ; 39(3): 689-694.e3, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37739141

ABSTRACT

BACKGROUND: The objective of this study was to identify the rate and risk factors for revision total knee arthroplasty (TKA) within the first 5 years postoperative. Our secondary objective was to identify the rate of additional surgical procedures and death. METHODS: We conducted a retrospective cohort study among patients in Ontario, Canada who underwent an elective, primary TKA between April 1, 2007, and March 31, 2014, for osteoarthritis. We excluded patients under 40 years and who had undergone a TKA within the previous 15 years. Our final study cohort included 94,193 patients. We reported the proportion of the study cohort who experienced revision surgery within 2 and 5 years of the primary TKA; secondary surgery within 5 years. We conducted Cochran-Armitage tests for trends to assess changes in the proportion of patients who experienced each of the study outcomes, and multivariable logistic regressions to evaluate predictors of a revision TKA. RESULTS: There were 3,112 (3.3%) patients who had a revision within 5 years, and 1,866 (2.0%) within 2 years of their primary TKA. 3,316 (3.5%) had a secondary surgery (0.6% patellar resurfacing; 1.6% manipulation; 1.3% synovectomy; 0.5% washout; 0.9% debridement). Lower age, men, lower income, higher comorbidity score, depression, previous arthroscopy, lower surgeon volume, and general anesthesia were all significant positive predictors of revision. CONCLUSIONS: In our study cohort, 2.0% of patients had a revision TKA within 2 years, and 3.3% within 5 years of their primary TKA. Preoperative identification of risk factors may reduce the future prevalence of revision TKAs.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Male , Humans , Arthroplasty, Replacement, Knee/adverse effects , Retrospective Studies , Treatment Outcome , Osteoarthritis, Knee/surgery , Osteoarthritis, Knee/etiology , Ontario/epidemiology , Reoperation/methods , Knee Joint/surgery
11.
J Arthroplasty ; 38(6S): S157-S163, 2023 06.
Article in English | MEDLINE | ID: mdl-37019318

ABSTRACT

BACKGROUND: Several studies have reported negative results after total knee arthroplasty (TKA) in obese patients. This study aims to analyze the minimum 2-year outcomes in patients who have a body mass index (BMI) > 35 undergoing cemented TKA using an all-polyethylene tibial component (APTC) at a minimum of 2 years of follow-up. METHODS: We retrospectively studied 163 obese patients (192 TKAs) who underwent a primary cemented TKA using an APTC comparing the outcomes of 96 TKA patients who had a BMI > 35 to 39.9 (group A) with 96 patients who a TKA and a BMI ≥40 (group B). Median follow-up of groups A and B were 3.8 years and 3.5 years respectively (P = .02). Multiple regression analyses were performed to evaluate independent risk factors associated with complications. Kaplan-Meier survival curves were estimated, defining failure as the need for any further femoral or tibial revision surgery with implant removal, irrespective of the reason. RESULTS: There was no significant difference at the latest follow-up patient-reported outcomes between both groups. Survivorship, as defined by revision for any reason, was 99% for group A and 99% for group B (P = 1.00). There was 1 aseptic tibial failure in group A, and 1 septic failure in group B. Multiple regression analyses showed no significant associations between age (odds ratio [OR] = 1.00; P = .98; 95% confidence interval (CI) = 0.93 to 1.08), sex (OR = 1.38; P = .70; 95% CI = 0.26 to 7.25), BMI (OR = 1.00; P = .95; 95% CI = 0.87 to 1.16), and complication rate. CONCLUSION: At a median 3.7-year follow-up, the use of an APTC provided excellent outcomes and survivorship in patients who had Class 2 and Class 3 obesity. LEVEL OF EVIDENCE: Level III, therapeutic study.


Subject(s)
Knee Prosthesis , Humans , Knee Joint/surgery , Body Mass Index , Polyethylene , Retrospective Studies , Prosthesis Failure , Obesity/complications , Obesity/surgery , Reoperation , Treatment Outcome , Prosthesis Design
12.
J Arthroplasty ; 38(6S): S297-S301, 2023 06.
Article in English | MEDLINE | ID: mdl-37003457

ABSTRACT

BACKGROUND: Hybrid fixation, utilizing diaphyseal press-fit stems and cement fixation in the tibial and femoral metaphyseal areas, has long been a strategy for revision total knee arthroplasty (rTKA). The purpose of this study was to evaluate the clinical outcomes and survivorships of hybrid fixation using a single rTKA revision system with a minimum of 5 years follow-up. METHODS: We reviewed our prospectively collected database to identify 281 patients who underwent rTKA using a single revision system with hybrid fixation and press-fit stems between July 2006 and August 2016. We reviewed the clinical outcome scores, including the Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis index, and Veterans RAND 12 Item Health Survey. We also evaluated the 5 and 10-year survivorships and the indications for reoperations. The cohort had a mean age of 70 years (range, 45.2 to 92.0) and a mean body mass index of 33.4 (range, 17.3 to 55.8). The mean time from rTKA surgery was 11.1 years (range, 5.3 to 15.5). RESULTS: Paired t-test analyses showed significant improvements from preoperative versus postoperative clinical outcome scores (P < .001) for Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis, and Veterans RAND 12 Item Health Survey Physical component. Prosthetic joint infections after index rTKA were the most common failure mode with 29 patients requiring reoperations. Rerevision due to aseptic loosening was uncommon (6 patients) with a cumulative survival rate of 95.2% at 5 years and 94.2% at 10 years. CONCLUSION: The use of this single rTKA system utilizing press fit stems combined with hybrid fixation provided significant improvements in the clinical outcomes and excellent survivorships at 5 and 10 years.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis , Humans , Aged , Knee Joint/surgery , Survivorship , Prosthesis Design , Reoperation , Osteoarthritis/surgery , Retrospective Studies , Prosthesis Failure , Treatment Outcome
13.
J Arthroplasty ; 38(7S): S223-S228, 2023 07.
Article in English | MEDLINE | ID: mdl-36963526

ABSTRACT

BACKGROUND: Subsidence remains a concern when utilizing tapered fluted titanium (TFT) femoral stems and may lead to leg length discrepancy, impingement, instability, and failure to obtain osseointegration. This study aims to compare stem subsidence across 3 modern TFT stems. Our secondary aim was to investigate the influence of bicortical contact or "scratch fit" on subsidence, as well as the role of intraoperative imaging in maximizing bicortical contact and preventing stem subsidence. METHODS: A retrospective review of 271 hip arthroplasties utilizing modern TFT stems at a single institution was performed. Three stem designs were included in the analysis: 1 monoblock TFT stem (n = 91) and 2 modular TFT stems (n = 90; n = 90). Patient demographics, Paprosky femoral bone loss classification, bicortical contact, utilization of intraoperative imaging, and stem subsidence (comparison of initial postoperative radiograph to the latest follow-up radiograph-minimum 3 months) were recorded. RESULTS: There was no statistically significant difference in overall subsidence (P = .191) or the incidence of subsidence >5 millimeters between stems (P = .126). Subgroup analysis based on femoral bone loss grading showed no difference in subsidence between stems. Increased bicortical contact was associated with reduced subsidence (P = .004). Intraoperative imaging was used in 46.5% (126 of 271) of cases; this was not correlated with bicortical contact (P = .673) or subsidence (P = .521). CONCLUSION: All 3 modern TFT stems were highly successful and associated with low rates of subsidence, regardless of modular or monoblock design. Surgeons should select the stem that they feel is most clinically appropriate.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Titanium , Prosthesis Design , Reoperation , Femur/diagnostic imaging , Femur/surgery , Retrospective Studies
14.
J Arthroplasty ; 38(6S): S355-S362, 2023 06.
Article in English | MEDLINE | ID: mdl-36758840

ABSTRACT

BACKGROUND: Contact kinematics in total knee arthroplasty (TKA) has been shown to affect tibial component migration. However, previous studies correlating kinematic variables to implant migration were completed with older TKA designs. The goal of this study was to determine if there are associations between contact kinematics and tibial component migration for a cemented, bicruciate stabilized (BCS) TKA system. METHODS: A total of 54 knees implanted with a BCS TKA system were analyzed using radiostereometric analysis (RSA). Patients underwent RSA exams at 2 weeks, 6 weeks, 3 months, 6 months, 1 year, and 2 years post operation to measure tibial component migration. At 1 year, contact kinematics was evaluated during a quasi-static deep knee bend. Linear regression analyses were performed between kinematic variables and migration values. RESULTS: Significant correlations were found between contact kinematics and tibial component migration. Excursion on the lateral condyle was the most consistent variable correlating with implant migration. Six patients had > 0.2 mm migrations from 1 to 2 years post operation indicating continuously migrating tibial components, and most had atypical contact kinematics. CONCLUSION: Kinematics was shown to influence tibial component migration. Reduced lateral excursion, suggesting a more constrained lateral condyle, resulted in greater implant migration. The 6 patients who had continuously migrating tibial components had demographic factors that may limit the ability to endure unintended force transmissions caused by abnormal kinematics. These results highlight the importance of restoring knee kinematics with this BCS TKA design to minimize improper force transmissions and resultant increased implant migrations.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Biomechanical Phenomena , Knee Joint/surgery , Knee/surgery , Osteoarthritis, Knee/surgery , Range of Motion, Articular
15.
Arthroplasty ; 4(1): 53, 2022 Dec 15.
Article in English | MEDLINE | ID: mdl-36522686

ABSTRACT

BACKGROUND: Posterior-stabilized (PS)-total knee arthroplasty (TKA) arose as an alternative to cruciate-retaining (CR)-TKA in the 1970s. Since then, it has become a popularly utilized TKA design with outcomes comparable to CR-TKA. The post-cam mechanism is unique to PS-TKA as it substitutes the function of the posterior cruciate ligament (PCL). The study aimed to understand the kinematic and laxity changes in PS-TKA with under- and overstuffing of the tibiofemoral joint space with the polyethylene (PE) insert. METHODS: This study employed a hybrid computational-experimental joint motion simulation on a VIVO 6 degrees of freedom (6-DoF) joint motion simulator (AMTI, Watertown, MA, USA). Physical prototypes of a virtually-performed TKA in mechanical alignment (MA) and kinematic alignment (KA) based on cadaveric CT scans and a virtual ligament model were utilized. The reference, understuffed (down 2 mm) and overstuffed (up 2 mm) joint spaces were simulated, neutral flexion and laxity testing loads and motions were performed for each configuration. RESULTS: The PE insert thickness influenced post-cam engagement, which occurred after 60º in the overstuffed configurations, after 60º-75º in the reference configurations and after 75º in the understuffed configurations. The understuffed configurations, compared to the reference configurations, resulted in a mean 2.0º (28%) and 2.0º (31%) increase in the coronal laxity in MA and KA respectively. The overstuffed configurations, compared to the reference configuration, resulted in an increase in the mean joint compressive forces (JCFs) by 73 N (61%) and 77 N (62%) in MA and KA models, respectively. CONCLUSIONS: The under- and overstuffing in PS-TKA alter the kinematics with variable effects. Understuffing decreases the stability, JCFs and inverse with overstuffing. Subtle changes in the PE insert thickness alter the post-cam mechanics.

16.
Can J Surg ; 65(5): E562-E566, 2022.
Article in English | MEDLINE | ID: mdl-36302132

ABSTRACT

BACKGROUND: Evidence suggests that up to 21% of patients are dissatisfied after total knee arthroplasty (TKA), but the link between dissatisfaction and use of health care resources is unknown. The objective of this study was to compare costs after TKA between satisfied and dissatisfied patients. METHODS: This was a secondary analysis of a randomized clinical trial among patients who underwent primary TKA at our institution between 2015 and 2018. We estimated rates of satisfaction with pain relief and with return to function 1 year postoperatively. Patients prospectively reported use of health care resources 6 weeks, and 3, 6, 9 and 12 months after surgery. We compared costs between satisfied and dissatisfied patients from a public payer and a societal perspective. RESULTS: We included 156 patients in our analysis, of whom 42 (26.9%) were dissatisfied with pain, and 57 (36.5%) were dissatisfied with function. There was no significant difference in costs between patients dissatisfied with pain or function compared to satisfied patients from a health care payer perspective. From a societal perspective, patients dissatisfied with pain incurred a mean cost of $21 156.18, compared to $13 453.84 for satisfied patients (mean difference $7702.34, 95% confidence interval [CI] -89.43 to 15 494.11). Similarly, patients dissatisfied with function incurred a mean cost of $19 007.70, compared to $13 523.83 for those who were satisfied (mean difference $5483.87, 95% CI -526.34 to 11 494.10). CONCLUSION: Dissatisfied patients incurred greater costs than satisfied patients during the first year after TKA. The results justify further evaluation of factors contributing to patient satisfaction that may help to reduce the economic burden of TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Osteoarthritis, Knee/surgery , Patient Satisfaction , Personal Satisfaction , Pain , Health Care Costs
17.
Can J Surg ; 65(4): E487-E495, 2022.
Article in English | MEDLINE | ID: mdl-35926882

ABSTRACT

BACKGROUND: The direct lateral (DL) approach to total hip arthroplasty is more commonly used than the newer direct anterior (DA) approach. Both approaches use collared or collarless femoral stems. We sought to assess implant stability of stem designs implanted with the DL approach and compare outcomes from this cohort with those of a previously reported cohort of patients who underwent arthroplasty with a DA approach. We also sought to determine if early recovery influences differences in migration. METHODS: Patients underwent total hip arthroplasty using the DL or the DA approach and were randomized to receive either a collared or collarless, cementless femoral stem. On the day of surgery and at 6 follow-up visits through to 1 year, patients underwent supine radiostereometric imaging to track implant migration. At follow-up visits, patients performed an instrumented walking test to assess their functional ability and logged an average daily step count to assess their activity levels. We assessed whether patient function and activity were correlated with migration. RESULTS: Stem design did not have a significant effect on migration for the DL group (p = 0.894). Compared with the DA group, the DL group migrated significantly less for both collared (p = 0.031) and collarless (p = 0.002) stems. Migration was not correlated with function or activity at any time point (p > 0.05). CONCLUSION: Most implant migration occurred from the day of surgery to 2 weeks after the operation and stabilized thereafter, suggesting adequate fixation and a low risk for aseptic loosening in both patient groups.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Femur/surgery , Hip Prosthesis/adverse effects , Humans , Prospective Studies , Prosthesis Design , Prosthesis Failure
18.
Arch Physiother ; 12(1): 16, 2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35836298

ABSTRACT

BACKGROUND: Research has demonstrated an increased risk of falls after total hip arthroplasty (THA). Yet, people's knowledge on falls risk factors and how falls prevention strategies are being used after THA have not been examined. If a person's knowledge of falls and self-efficacy about falls prevention strategies is low this would indicate a pressing need for interventions to lessen risk. The study objectives were: 1) to determine the falls knowledge and what fall prevention strategies people used after (THA) and 2) to determine the outcomes of a falls risk assessment at 12-months after unilateral THA. METHODS: Overall, 108 people completed the Falls Risk for Older People - Community Setting (FROP-Com) scale, a falls questionnaire (covered occurrence of falls, knowledge on falls risk factors, falls prevention strategies implemented after THA surgery), 6-m Walk Test (6mWT), 30-Second Chair Stand Test (30CST), Timed-up and Go (TUG) Test, and Activities-specific Balance Confidence Scale (ABC). RESULTS: Twenty-five (23.2%) people fell at least once in the 12 months after THA. Scores on the FROP-Com ranged from 2-20 with an average of 8.2 ± 3.6 indicating a mild falls risk. The importance of falling compared to other health concerns was rated as moderate to high (6.8 ± 2.9) and the majority of participants (n = 98, 90.7%) believed falls can be prevented after THA. Total scores on the ABC scale ranged from 30.6% to 100.0% with an average score of 84.4 ± 15.5%, indicating high function. Only 47 people (43.5%) reported receiving falls prevention education. A total of 101 falls prevention strategies were completed by 67 people (62%), the most common strategy was environmental modifications (e.g., installation of grab bars) at 37.4%, while exercise was mentioned by only 2%. The majority of people had functional deficits in 30CST (62%) and TUG (76.9%) at 12-months after unilateral THA. CONCLUSIONS: Almost a quarter of the sample had experienced a fall in the 12-months after THA and functional deficits were common. The majority of the sample had proactively implemented falls prevention strategies after the surgery. Yet importantly, people after THA had limited exposure to falls prevention education and implemented a limited range of prevention strategies.

19.
J Arthroplasty ; 37(6S): S98-S104, 2022 06.
Article in English | MEDLINE | ID: mdl-35569919

ABSTRACT

BACKGROUND: Implant migration and altered kinematics have been thought to impact patient-reported outcome measures (PROMs) and postoperative patient satisfaction. In this study comparing satisfied and dissatisfied total knee arthroplasty (TKA) patients, we hypothesized that dissatisfied patients will have greater continuous implant migration and that there will be differences in joint kinematics, objective functional measurements, and PROMs between satisfied and dissatisfied patients. METHODS: The Knee Society Score Satisfaction Subsection questions regarding satisfaction with function were used at least 6 months postoperation to split 50 patients into satisfied and dissatisfied groups. Patients underwent radiostereometric analysis to evaluate migration and kinematics. A wearable sensor system obtained objective measurements of patient function during timed up and go tests. PROMs were recorded preoperation and postoperation. RESULTS: No statistically significant differences were found in migration between satisfied and dissatisfied groups. Statistical kinematic differences existed in lateral anteroposterior contact location at 20° and 40° of flexion at 1 year, where the dissatisfied group had more anteriorly located lateral contact. No statistically significant differences were present in objective functional measurements. Satisfied and dissatisfied groups had differing PROMs at 4 timepoints or greater for each questionnaire. CONCLUSIONS: No differences were found in tibial component migration or objectively measured function between satisfied and dissatisfied patients. Functionally dissatisfied patients had more anteriorly positioned contact on the lateral condyle in early flexion and reported more pain and unmet expectations. These findings suggest that improving the functional satisfaction of TKA requires restoration of kinematics in early flexion and management of patient's pain and expectations.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Biomechanical Phenomena , Humans , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Pain/surgery , Patient Satisfaction , Personal Satisfaction , Range of Motion, Articular
20.
J Arthroplasty ; 37(11): 2262-2271, 2022 11.
Article in English | MEDLINE | ID: mdl-35598759

ABSTRACT

BACKGROUND: The prevalence and outcomes of unexpected positive intraoperative cultures (UPC) in presumed aseptic revision total knee arthroplasty (TKA) are unclear. The purpose of this study was to determine the prevalence of UPC and infection-free implant survival in this patient population. Secondly, we aimed to compare the infection-free implant survival between cohorts based on number of UPCs and antibiotic treatment. METHODS: We reviewed our institutional database from 2006 to 2019 for all TKA revisions (n = 1795) to identify all presumed aseptic TKA revisions with intraoperative culture(s). After exclusions, 775 revisions were eligible and those with UPC were included in the Kaplan-Meier analysis to determine infection-free implant survival for the cohorts. RESULTS: The prevalence of UPC was 9.8%. The 2- and 5-year infection-free survival was 97.4% and 95.3%, respectively. The 5-year infection-free survival from the same microorganism as the UPC was 98.7%. Infection-free survival was similar for the 1 versus ≥2 UPC cohorts (P = .416), however was poorer for the cohort treated with antibiotics (P = .021). Only one of 3 subsequent PJI-related implant failures was caused by the same microorganism (polymicrobial) as the UPC. There were no subsequent infections in patients with a single UPC not treated with antibiotics. CONCLUSIONS: The prevalence of UPC was 9.8% and the infection-free implant survival is excellent. Infection-free survivorship from PJI caused by the same UPC microorganism is outstanding. Comparisons between cohorts must be interpreted with caution due to study limitations. A single UPC in patents without other signs of infection does not require antibiotic treatment. LEVEL OF EVIDENCE: IV.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis-Related Infections , Anti-Bacterial Agents/therapeutic use , Arthroplasty, Replacement, Knee/adverse effects , Humans , Knee Prosthesis/adverse effects , Prevalence , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/etiology , Reoperation/adverse effects , Retrospective Studies