Results 1 - 20 de 148
Filter
1.
J Refract Surg ; 40(5): e304-e312, 2024 May.
Article in English | MEDLINE | ID: mdl-38717085

ABSTRACT

PURPOSE: To compare intraoperative performance and early postoperative outcomes following phacoemulsification with two systems using active fluidics and one using gravity-based fluidics. METHODS: In this prospective randomized trial, 200 eyes were randomized to the traditional and Active Sentry groups (n = 80 eyes each) where the Centurion Vision System was used with traditional or Active Sentry (Alcon Laboratories, Inc) hand-pieces, respectively, or the Infinit group (n = 40 eyes) where the Infiniti Vision System (Alcon Laboratories, Inc) was used. Within the traditional and Active Sentry groups, there were two subgroups with low (30 mm Hg) or high (55 mm Hg) intraocular pressure (IOP) used. Outcome measures compared were: cumulative dissipated energy (CDE), percentage change in central corneal thickness (CCT) at 1 day, 1 week, and 1 month, anterior chamber cells at 1 day and 1 week, rate of rise and fall of IOP following occlusion break, corneal endothelial cell density (ECD), and macular thickness 6 months postoperatively. RESULTS: CDE was significantly lower in group II compared to the traditional group (2.96 ± 1.4 vs 4.14 ± 2.2, P = .001). With 30 mm Hg IOP, the Active Sentry group had significantly less percentage change in CCT at 1 week postoperatively compared to the traditional handpiece group (0.01% vs 0.02%, P = .008). Incidence of anterior chamber cells less than grade 2 on day 1 was significantly higher in the Active Sentry group (82.9% vs 52%, P = .03). Percentage change in ECD was significantly lower in the Active Sentry group (-0.957 vs -0.98%, P = .005). Significantly faster rise of IOP to baseline following occlusion break was seen in the Active Sentry group. CONCLUSIONS: The use of Active Sentry handpiece was associated with lower CDE, less postoperative increase in CCT, fewer anterior chamber cells, and faster rise of IOP following occlusion break. [J Refract Surg. 2024;40(5):e304-e312.].


Subject(s)
Intraocular Pressure , Lens Implantation, Intraocular , Phacoemulsification , Visual Acuity , Humans , Prospective Studies , Intraocular Pressure/physiology , Male , Female , Aged , Visual Acuity/physiology , Middle Aged , Endothelium, Corneal/pathology , Cell Count , Postoperative Period , Tomography, Optical Coherence , Hydrodynamics , Anterior Chamber , Intraoperative Period
2.
Article in English | MEDLINE | ID: mdl-38595138

ABSTRACT

PURPOSE: To compare visual outcomes and patient satisfaction following bilateral implantation of a non-diffractive extended vision intraocular lens(IOL) when targeting emmetropia versus mini-monovision. SETTING: Iladevi Cataract & IOL Research Centre,India. DESIGN: Prospective,randomized controlled trial. METHODS: Patients undergoing bilateral cataract surgery with an extended vision IOL(Vivity, Alcon Laboratories, USA) randomized to: group I- IOL implantation with emmetropic target in both eyes, or group II- IOL implantation with mini-monovision of -0.5 diopters(D). Outcome measures evaluated 6 months postoperatively were: unaided and corrected near visual acuity(UNVA, CNVA) at 40 centimeters(cm), unaided and corrected distance(UDVA, CDVA) and intermediate (UIVA, CIVA) visual acuity at 66cm. Mesopic contrast sensitivity, binocular defocus curve, patient reported spectacle independence questionnaire and satisfaction on the McAlinden questionnaire were also assessed. RESULTS: 70 patients enrolled in study. 34 and 33 patients in groups I and II completed follow-up. Binocular UNVA was significantly better in group II (0.26+0.05 vs 0.22+0.08 LogMAR, P=0.03). Reading add required in group II was significantly lower. UIVA (0.09+0.06 vs 0.07+0.08 LogMAR, P=0.15) and UDVA (0.02+0.04 vs 0.02+0.05 LogMAR, P=0.78) were not significantly different between groups. Mesopic contrast sensitivity was not significantly different between the groups. Binocular defocus curve showed significantly better mean visual acuities between -2.0 to -3.0 diopters in group II. Patients in both groups had high levels of spectacle independence, with no patient reporting dysphotopsia. CONCLUSION: Binocular UNVA was significantly better, with comparable UDVA and mesopic contrast sensitivity when targeting mini monovision with the non-diffractive extended vision IOL as compared to targeting binocular emmetropia.

3.
Article in English | MEDLINE | ID: mdl-36644780

ABSTRACT

Background: Plant elements and extracts have been used for centuries to treat a wide range of diseases, from cancer to modern lifestyle ailments like viral infections. These plant-based miRNAs have the capacity to control physiological and pathological conditions in both humans and animals, and they might be helpful in the detection and treatment of a variety of diseases. The present study investigates the miRNA of the well-known spice Curcuma Longa and its prospective targets using a variety of bioinformatics techniques. Results: Using the integrative database of animal, plant, and viral microRNAs known as miRNEST 2.0, nine C. longa miRNAs were predicted. psRNA target service foretells the presence of 23 human target genes linked to a variety of disorders. By interacting with a variety of cellular and metabolic processes, miRNAs 167, 1525, and 756 have been found to be critical regulators of tumour microenvironment. SARS-cov2 and influenza A virus regulation have been connected to ZFP36L1 from miRNA 1525 and ETV5 from miRNA 756, respectively. Conclusions: The current cross-kingdom study offers fresh knowledge about how to increase the effectiveness of plant-based therapies for disease prevention and serves as a platform for in vitro and in vivo research development.

4.
J Cataract Refract Surg ; 49(2): 159-164, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36194106

ABSTRACT

PURPOSE: To report intraoperative performance and postoperative outcomes of femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification (PE) in the hands of junior surgeons. SETTING: Iladevi Cataract & IOL Research Centre, Ahmedabad, Gujarat, India. DESIGN: Prospective single-masked randomized controlled trial. METHODS: 320 eyes (320 patients) undergoing cataract surgery for uneventful cataracts in the hands of junior surgeons were randomized to Group 1-FLACS or Group 2-PE. Intraoperatively, cumulative dissipated energy (CDE) and fluid used were compared. Postoperatively, the following were compared: central corneal thickness (CCT) on day 1, 1 week, and 1 month; corneal clarity (day 1 and 1 week); anterior chamber inflammation (day 1 and 1 week); change in endothelial cell density (ECD) at 6 months postoperatively; and corrected distance visual acuity (CDVA) at 1 week and 1 month postoperatively. RESULTS: 157 and 158 patients in groups 1 and 2 analysed. Intraoperatively, CDE (5.41 ± 2.73 vs 8.83 ± 4.28 in Groups 1 and 2, P = .0001) and fluid used (79.33 ± 33.46 vs 101.82 ± 32.23 mL in Groups 1 and 2, P < .0001) were significantly lesser in Group 1. CCT was significantly higher in Group 2 on day 1 (550.96 ± 33.64 vs 587.70 ± 55.76 µm in Groups 1 and 2, P < .0001) and at 1 week postoperatively (527.94 ± 30.78 vs 545.11 ± 35.17 µm in Groups 1 and 2, P = .001). 72% of eyes had clear corneas on day 1 in Group 1 compared with 39% in Group 2 ( P = .01). Anterior chamber inflammation and CDVA were comparable. Change in ECD was significantly lower (9.3%) in Group 1 vs 12.7% in Group 2, P < .0001. CONCLUSIONS: FLACS showed lower intraoperative CDE, fluid usage, lesser increase in CCT, better early postoperative corneal clarity, and lesser change in ECD at 6 months postoperatively in the hands of junior surgeons during standard cataract surgery.


Subject(s)
Cataract Extraction , Cataract , Laser Therapy , Phacoemulsification , Surgeons , Humans , Prospective Studies , Cataract/complications , Lasers
5.
J Biosci ; 472022.
Article in English | MEDLINE | ID: mdl-36222151

ABSTRACT

Growth factor-induced migration of lens epithelial cell (LEC) toward the posterior of lens capsule bag and their epithelial-mesenchymal transition (EMT) is the key process involved in the pathogenesis of posterior capsular opacification (PCO). Silibinin, a natural flavonolignan, confers therapeutic effects to different cells by regulation of signalling pathways; however, its role in the prevention of migration and EMT of LECs is yet to be analysed. In this study, the inhibitory capabilities of silibinin on migration and EMT were analysed in response to TGFß2 stimulation in HLE B-3 cells. The anti-migratory effect of silibinin was analysed using wound healing assay. Transcriptional and translational expression of genes related to LEC migration, EMT, and transcription factors related to EMT were studied by quantitative real-time PCR and Western blotting. Immunofluorescence analysis was utilized to study the localization of fibronectin. Silibinin reduced the viability of LECs in a concentration-dependent manner and inhibited the wound healing capacity of LECs induced by TGFß2. Silibinin also suppressed alteration in the EMT-related markers such as cytoskeletal proteins, cell adhesion markers, extracellular matrix molecules, and transcription factors. Analysis of downstream signalling revealed that treatment with silibinin decreased phosphorylated Akt (Ser473, Thr308), PDK1 (Ser241), PTEN (Ser380), c-Raf (Ser259), and GSK3ß (Ser9) in TGFß-stimulated cells. The effect of silibinin treatment on phosphorylated Akt resembled that of the PI3K inhibitor LY294002. Our results suggest that silibinin can suppress LEC migration and EMT, which involves the inactivation of the PI3K-Akt signalling pathway. Silibinin might be a good candidate for PCO prevention; however, functional evaluation of silibinin using in vivo models is a pre-requisite.


Subject(s)
Capsule Opacification , Flavonolignans , Lens, Crystalline , Capsule Opacification/metabolism , Cell Movement , Cell Proliferation , Cytoskeletal Proteins/metabolism , Epithelial Cells/metabolism , Epithelial-Mesenchymal Transition/genetics , Fibronectins/metabolism , Flavonolignans/metabolism , Flavonolignans/pharmacology , Glycogen Synthase Kinase 3 beta , Humans , Phosphatidylinositol 3-Kinases/genetics , Phosphatidylinositol 3-Kinases/metabolism , Proto-Oncogene Proteins c-akt/genetics , Proto-Oncogene Proteins c-akt/metabolism , Silybin/metabolism , Silybin/pharmacology , Transcription Factors/metabolism , Transforming Growth Factor beta2/genetics , Transforming Growth Factor beta2/metabolism , Transforming Growth Factor beta2/pharmacology
6.
Futur J Pharm Sci ; 8(1): 24, 2022.
Article in English | MEDLINE | ID: mdl-35382490

ABSTRACT

Background: Researchers now have a new avenue to investigate when it comes to miRNA-based therapeutics. miRNAs have the potential to be valuable biomarkers for disease detection. Variations in miRNA levels may be able to predict changes in normal physiological processes. At the epigenetic level, miRNA has been identified as a promising candidate for distinguishing and treating various diseases and defects. Main body: In recent pharmacology, plants miRNA-based drugs have demonstrated a potential role in drug therapeutics. The purpose of this review paper is to discuss miRNA-based therapeutics, the role of miRNA in pharmacoepigenetics modulations, plant miRNA inter-kingdom regulation, and the therapeutic value and application of plant miRNA for cross-kingdom approaches. Target prediction and complementarity with host genes, as well as cross-kingdom gene interactions with plant miRNAs, are also revealed by bioinformatics research. We also show how plant miRNA can be transmitted from one species to another by crossing kingdom boundaries in this review. Despite several unidentified barriers to plant miRNA cross-transfer, plant miRNA-based gene regulation in trans-kingdom gene regulation may soon be valued as a possible approach in plant-based drug therapeutics. Conclusion: This review summarised the biochemical synthesis of miRNAs, pharmacoepigenetics, drug therapeutics and miRNA transkingdom transfer.

7.
J Cataract Refract Surg ; 47(9): 1205-1209, 2021 Sep 01.
Article in English | MEDLINE | ID: mdl-33929803

ABSTRACT

PURPOSE: To compare real-time intraocular pressure (IOP) response to occlusion break event in 2 phacoemulsification systems. SETTING: Iladevi Cataract and IOL Research Center, India. DESIGN: Randomized, experimental study. METHODS: Rabbits were randomized to:Group I (n = 10 eyes), Centurion Vision system with active fluidics, or, Group II (n = 10 eyes), Centurion with Active Sentry. Within each group, parameter set 1 (IOP 30 mm Hg, aspiration flow rate [AFR] 20 mL/min, and vacuum 600 mm Hg) and parameter set 2 (IOP 50 mm Hg, AFR 25 mL/min, and vacuum 600 mm Hg) were tested. Real-time rate of drop and rise of IOP after occlusion break event (mm Hg per second) and percentage reduction of IOP from maximum during nuclear fragment removal were compared. RESULTS: 10 rabbits (20 eyes) were included. Rate of drop of IOP after occlusion break was not significantly different between groups. Rate of rise of IOP was statistically significantly higher in Group II with both parameter sets (199.09 ± 69.28 vs 94.33 ± 45.66 in parameter set 1, P = .006; and 256 ± 45.05 vs 165.25 ± 51.80 in parameter set 2, P = .005), suggesting faster recovery to baseline IOP after occlusion break. The mean percentage reduction of IOP from maximum was significantly higher in Group I (P = .003). CONCLUSIONS: Rise of IOP to baseline after occlusion break event was faster and mean percentage reduction of IOP from maximum during nuclear fragment removal was lower when using the Centurion Vision system with the Active Sentry upgrade compared with the traditional handpiece. The ability to sense IOP at the level of the handpiece with the Active Sentry upgrade allows faster mitigation of surge response.


Subject(s)
Cataract , Phacoemulsification , Animals , Rabbits , Intraocular Pressure , Tonometry, Ocular , Vacuum
8.
J Cataract Refract Surg ; 47(7): 842-846, 2021 07 01.
Article in English | MEDLINE | ID: mdl-33315732

ABSTRACT

PURPOSE: To analyze exhaled airflow patterns in a clinical scenario and the impact of infection control practices and room air circulation in context of the COVID-19 pandemic. SETTING: Raghudeep Eye Hospital, India. DESIGN: Experimental study. METHODS: Ten patients attending ophthalmic outpatient clinic (OPD) and operating room (OR) were included. Using Schlieren imaging, exhaled airflow patterns were documented with/without an N95 mask or face shield during respiratory activities. Recordings were performed with and without room air conditioning turned on. Exhaled airflow patterns in OPD and OR when using vs not using these infection control measures and the impact of room air circulation on these were compared. RESULTS: Five patients each in OPD and OR were included. There was a forward stream of exhaled air from the patient's mouth/nose during all respiratory activities. An N95 mask dampened its intensity and forward transmission. Taping the mask around the nasal bridge further reduced airflow leakage. A mechanical barrier in front of the patient's face blocked forward propagation of the exhaled airflow. Turning on a forceful and direct draft of air over the surgeon's working area dampened and diverted the exhaled airflow away from the surgeons' breathing area. This effect was particularly pronounced in the OR, with the overhead laminar airflow. CONCLUSIONS: Using high force airflow with the draft facing downward can dampen and divert the exhaled airflow away from healthcare providers. Using masks/mechanical barriers and taping the mask reduces potential dissemination of aerosols and, thereby, human and surface contamination.


Subject(s)
COVID-19 , Pandemics , Humans , India/epidemiology , Infection Control , Masks , SARS-CoV-2
9.
J Cataract Refract Surg ; 47(4): 522-532, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-32925648

ABSTRACT

The proximity of the iris to the instruments and currents of cataract surgery makes iatrogenic damage to the iris a common complication of cataract surgery. This article discusses techniques to prevent or minimize this damage. When damage does occur, the surgeon must decide if, when, and how to repair the damage. Principles governing these decisions and techniques for repair are discussed. Figures and videos, included as online Supplemental Data files, illustrate cases of iatrogenic damage and repair techniques.


Subject(s)
Cataract Extraction , Cataract , Ophthalmology , Humans , Iatrogenic Disease , Iris/surgery
10.
Indian J Ophthalmol ; 68(11): 2476-2478, 2020 11.
Article in English | MEDLINE | ID: mdl-33120645

ABSTRACT

In the present study, we describe a step-by-step technique for cortex aspiration during cataract surgery- POPS (positioning, occlusion, posterior displacement, and swiping). Firstly, the aspiration probe is positioned under the bulk of cortical fibers beyond the capsulorhexis margin. Subsequently, the aspiration port is occluded with minimal vacuum, and the occluded port is displaced posteriorly to detach the cortical fibers off the anterior capsule. Now, tangential, arc-like swiping movements are performed while gradually increasing vacuum at the same time. The fibers are brought to the center and finally aspirated. This allows complete removal of the equatorial fibers and lens epithelial cells (LEC) with the least stress to the capsulozonular complex. Unlike the conventional technique, which involves the radial pull of cortical fibers, in this technique, there is swiping and posterior displacement of the cortical fibers before pulling towards the center and aspirating. We believe this technique will ensure safer, more effective cortical and LEC removal, reducing zonular stress.


Subject(s)
Cataract Extraction , Cataract , Lens, Crystalline , Capsulorhexis , Epithelial Cells , Humans , Vacuum
11.
Indian J Ophthalmol ; 68(10): 2103-2106, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32971617

ABSTRACT

PURPOSE: The purpose of this study is to evaluate fluid droplet spray generation during phacoemulsification (PE), pars plana vitrectomy (PPV), and fragmatome lensectomy (FL) and assess factors affecting these. METHODS: This is an experimental study. PE through 2.2 and 2.8 mm incisions was performed in six goat eyes and four simulator eyes using both continuous and interrupted ultrasound (U/S). PPV and FL were performed in three goat eyes. Generation of visible fluid droplet spray was analyzed from video recordings through the microscope camera and an external digital camera. Hydroxypropylmethylcellulose (HPMC) was applied over the incision site during PE and FL. RESULTS: When PE was performed through both incision sizes, there was no visible fluid droplet spray if the phaco tip was centered in the incision, without sleeve compression. When there was phaco tip movement with the phaco sleeve sandwiched between the tip and the incision wall, there was visible fluid droplet spray generation. It was more difficult to induce fluid droplet spray with 2.8 mm incision, and spray was lesser with interrupted U/S. During PPV, there was no droplet spray. During FL, fluid droplet spray was only seen when U/S was delivered with the fragmatome tip close to the sclerotomy. HPMC impeded droplet spray. CONCLUSION: Fluid droplet generation during PE can be minimized to a large extent by keeping the phaco tip centered within the incision, avoiding sleeve compression. Smaller incision and continuous U/S were more prone to droplet generation. FL should be performed away from sclerotomy. HPMC over incision is recommended.


Subject(s)
Betacoronavirus , Body Fluids/chemistry , Coronavirus Infections/epidemiology , Intraoperative Complications , Microbubbles , Phacoemulsification/instrumentation , Pneumonia, Viral/epidemiology , Vitrectomy/instrumentation , Animal Experimentation , Animals , COVID-19 , Coronavirus Infections/prevention & control , Goats , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Pandemics/prevention & control , Photography , Pneumonia, Viral/prevention & control , SARS-CoV-2 , Video Recording
12.
J Cataract Refract Surg ; 46(11): 1480-1486, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32649434

ABSTRACT

PURPOSE: To report intraoperative performance and long-term postoperative outcomes after scleral fixation of intraocular lenses (IOLs) with polytetrafluoroethylene suture (PTFE). SETTING: Raghudeep Eye Hospital, Ahmedabad, India. DESIGN: Prospective, interventional case series. METHODS: One hundred eyes undergoing scleral fixation of IOLs using PTFE suture (Gore-Tex) with 12 months or more postoperative follow-up were included. The primary outcome measures were occurrence of intraoperative and postoperative complications such as glaucoma, suture-related complications, and inflammation within the follow-up period. The secondary outcome measure was improvement in visual acuity (VA). RESULTS: Of the 100 eyes, posteriorly dislocated IOLs (53 eyes) followed by dropped nuclei (33 eyes) were the most common surgical indications. Mean follow-up was 23 months (range 12 months to 5 years). Seventy-one patients (77.17%) had 18 months or more follow-up; 21 eyes had a rise in intraocular pressure in the early postoperative period; 12 of them required glaucoma surgery. Early complications were vitreous hemorrhage in 13 eyes, retinal detachment in 6 eyes, and transient hyphema in 1 eye. Late postoperative complications were cystoid macular edema (9 eyes), epiretinal membrane (3 eyes), and bullous keratopathy (3 eyes). Mean VA improved from 0.92 ± 0.16 (SD) logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.41 ± 0.27 logMAR. LogMAR at final follow-up was 0.41 ± 0.28 (P < .01). There were no cases of suture-related complications (erosion/breakage/granuloma) or IOL decentration throughout the follow-up period. CONCLUSIONS: Scleral fixation of IOLs with PTFE suture was found to be safe and well tolerated. All eyes had well-centered IOLs, with no suture-related complications during long-term follow-up. VA improved significantly with acceptable postoperative complications.


Subject(s)
Lenses, Intraocular , Polytetrafluoroethylene , Follow-Up Studies , Humans , India , Lens Implantation, Intraocular , Postoperative Complications , Postoperative Period , Prospective Studies , Retrospective Studies , Sclera/surgery , Suture Techniques , Sutures
13.
J Cataract Refract Surg ; 46(8): 1102-1107, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32569028

ABSTRACT

PURPOSE: To evaluate long-term visual outcomes and complications after toric intraocular lens (IOL) implantation in children with preexisting corneal astigmatism undergoing cataract surgery. SETTING: Iladevi Cataract & IOL Research Center, Ahmedabad, India. DESIGN: Prospective, interventional case series. METHODS: Children with regular corneal astigmatism of at least 1.5 diopters (D) were included. A standardized surgical technique with in-the-bag implantation of a toric IOL was performed. All children were followed up on postoperative day 1 and periodically thereafter, until 36 months postoperatively. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and residual refractive astigmatism were documented 36 months postoperatively. Rotational stability of toric IOL was also evaluated through the follow-up duration. Complications, particularly visual axis obscuration (VAO) and glaucoma, were documented. RESULTS: In total, 76 eyes (51 children) were included in the study. Mean age at surgery was 7.41 ± 2.82 years (SD) and mean preoperative keratometric astigmatism was 1.56 ± 2.13 D. The CDVA (logarithm of the minimum angle of resolution [logMAR]) improved significantly from 0.59 ± 0.43 preoperatively to 0.23 ± 0.27 36 months postoperatively (P = .03). Mean postoperative UDVA was 0.32 ± 0.26 logMAR. Mean refractive astigmatism at final follow-up was -0.55 ± 0.40 D, with 74% patients having a UDVA of at least 20/40; 5% of eyes needed VAO treatment and none developed glaucoma. No eye required repositioning of toric IOL until final follow-up. CONCLUSIONS: Toric IOL implantation reduced postoperative refractive astigmatism and gave excellent UDVA at 36 months follow-up in pediatric eyes undergoing nontraumatic cataract surgery.


Subject(s)
Astigmatism , Cataract , Lenses, Intraocular , Phacoemulsification , Astigmatism/surgery , Cataract/complications , Child , Humans , India , Lens Implantation, Intraocular , Prospective Studies , Refraction, Ocular
14.
Indian J Ophthalmol ; 67(10): 1618-1622, 2019 10.
Article in English | MEDLINE | ID: mdl-31546493

ABSTRACT

Purpose: To measure levels of collagen-derived antiangiogenic factors (arresten, canstatin, tumstatin, endostatin) and matrix metalloproteinases (MMP-2 and MMP-9) in anterior lens epithelial cells (LECs) and anterior capsules of children with cataract and persistent fetal vasculature (PFV) as cases and cataract without PFV as controls. Methods: Anterior capsules harboring LECs were collected from pediatric cataract patients with (n = 13) and without PFV (n = 13) during surgery. Samples were immediately subjected to RNA extraction and cDNA preparation. Quantitative real time PCR was performed to determine the mRNA levels of antiangiogenic factors and matrix metalloproteinases. GAPDH (Glyceraldehyde 3-Phosphate Dehydrogenase) and ß Actin were used as the housekeeping control. The mRNA levels were expressed as a ratio, using the delta-delta method for comparing the relative expression results between controls and cases. The non-parametric Mann-Whitney U test was applied for statistical evaluation. P values < 0.05 were statistically significant. Results: The relative mRNA levels of arresten, canstatin, tumstatin, endostatin, MMP-2 and MMP-9 in cases were 6.20E-03 ± 0.003, 1.49E-01 ± 0.02, 1.70E-01 ± 0.007, 3.20E-03 ± 0.003, 1.11E-03 ± 0.0009 and 3.72E-04 ± 0.0001. The mRNA levels of arresten was 1.6 times lower (P = 0.01) while mRNA levels of MMP-2, tumstatin and canstatin were 4, 2.5, and 2.3 times higher in cases than in controls. No change was observed in mRNA levels of MMP-9 and endostatin (P = 0.82). Conclusion: A significant difference in the levels of arresten, canstatin, tumstatin, and MMP-2 was found in LECs with PFV.


Subject(s)
Angiogenesis Inhibitors/genetics , Anterior Capsule of the Lens/cytology , Collagen Type IV/genetics , Epithelial Cells/metabolism , Gene Expression Regulation/physiology , Matrix Metalloproteinases/genetics , Persistent Hyperplastic Primary Vitreous/complications , Child , Child, Preschool , Female , Humans , Infant , Male , Matrix Metalloproteinase 2/genetics , Matrix Metalloproteinase 9/genetics , RNA, Messenger/genetics , Real-Time Polymerase Chain Reaction
15.
Indian J Ophthalmol ; 67(10): 1634-1637, 2019 10.
Article in English | MEDLINE | ID: mdl-31546498

ABSTRACT

Purpose: To evaluate the eff ect of different aspiration flow rates (AFR) and bottle heights (BH) on vitreous face (AVF) during phacoemulsifi cation. Methods: Experimental study in 20 porcine eyes. Transzonular viscodissection was performed between the posterior capsule(PC) and AVF to dissect out the Berger's space. Triamcinolone acetonide was injected into this space to aid visualization with ultrasound B-Scan(USG). Realtime USG was performed during phacoemulsifi cation. Eyes were divided randomly into-Group I: Low parameters(AFR = 20 cc/min, BH = 90 cm, vacuum = 400 mmHg),and Group II: High parameters (AFR = 40 cc/min, BH = 110 cm, vacuum=650 mm Hg). Results: 15 eyes were analysed (8 in Group I; 7 in Group II). In all eyes, forward and backward movement of the PC was seen when going from foot position 0 to 1, or on occlusion break. Amplitude of these movements was much greater in Group II compared to Group I. There was no PC rupture in either group. In 2 of the 7 eyes in Group II, USG showed a sudden, spontaneous dispersion appearance of sono-opaque echoes in the vitreous cavity alongwith disappearance of the well-defi ned, crescentic stained space despite an intact PC. This suggests rupture of the AVF, leading to dispersion of the triamcinolone into the entire vitreous cavity. No AVF rupture was seen in Group I. Conclusion: We report a rarely described entity of AVF rupture with intact PC. The use of high AFR and BH may have clinically invisible detrimental consequences to the anterior vitreous face.


Subject(s)
Anterior Chamber/diagnostic imaging , Intraocular Pressure/physiology , Phacoemulsification/methods , Posterior Capsule of the Lens/diagnostic imaging , Vitrectomy/methods , Vitreous Body/diagnostic imaging , Animals , Anterior Chamber/surgery , Disease Models, Animal , Intraoperative Period , Lens Implantation, Intraocular , Swine , Ultrasonography , Vitreous Body/surgery
17.
J Cataract Refract Surg ; 45(5): 547-552, 2019 05.
Article in English | MEDLINE | ID: mdl-31030773

ABSTRACT

PURPOSE: To compare intraoperative performance and postoperative outcomes between femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification in eyes with a shallow anterior chamber (AC). SETTING: Iladevi Cataract & IOL Research Centre, India. DESIGN: Prospective randomized masked clinical study. METHODS: Patients undergoing cataract surgery with a shallow AC (<2.5 mm) were randomized to have FLACS (Group 1, n = 91) or conventional phacoemulsification (Group 2, n = 91). Patients were followed up at 1 day, 1 week, and at 1, 3, and 6 months. The primary outcome measure was central corneal thickness (CCT). The secondary outcome measures were corneal clarity, AC cells and flare, endothelial cell density (ECD), coefficient of variance, hexagonality, and uncorrected distance visual acuity (UDVA) at 1 week. RESULTS: The study comprised 182 eyes (91 in each group) The cumulative dissipative energy was lower in the FLACS group (P < .05). The mean CCT was significantly lower with FLACS (540.40 µm + 49.40 [SD] vs 556 + 12.5 µm, P = .03) at 1 day and 1 week (535.5 + 44.3 µm vs 551 + 40.8 µm, P = .04), with fewer eyes having higher than grade 2 AC cells and flare with FLACS (85% vs 72%, P = .056) at 1 day and 1 week (15% vs 28%, P = .03). At 1 week, the UDVA was better with FLACS (0.089 ± 0.31 logarithm of the minimum angle of resolution [logMAR] vs 0.178 ± 0.65 logMAR, P = .042). At 6 months, the reduction in ECD was lower in the FLACS group; however, the difference was not statistically significant. CONCLUSION: In eyes with shallow ACs, compared with conventional phacoemulsification, FLACS maintained clearer corneas, showed less increase in CCT, lower AC inflammation, and better UDVA in the early postoperative period.


Subject(s)
Anterior Chamber/surgery , Laser Therapy/methods , Phacoemulsification/methods , Visual Acuity , Aged , Anterior Chamber/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Single-Blind Method , Tomography, Optical Coherence/methods , Treatment Outcome
18.
Curr Drug Metab ; 20(14): 1167-1190, 2019.
Article in English | MEDLINE | ID: mdl-31902350

ABSTRACT

BACKGROUND: Nanoparticles (NPs) are being used extensively owing to their increased surface area, targeted delivery and enhanced retention. NPs have the potential to be used in many disease conditions. Despite widespread use, their toxicity and clinical safety still remain a major concern. OBJECTIVE: The purpose of this study was to explore the metabolism and toxicological effects of nanotherapeutics. METHODS: Comprehensive, time-bound literature search was done covering the period from 2010 till date. The primary focus was on the metabolism of NP including their adsorption, degradation, clearance, and bio-persistence. This review also focuses on updated investigations on NPs with respect to their toxic effects on various in vitro and in vivo experimental models. RESULTS: Nanotechnology is a thriving field of biomedical research and an efficient drug delivery system. Further their applications are under investigation for diagnosis of disease and as medical devices. CONCLUSION: The toxicity of NPs is a major concern in the application of NPs as therapeutics. Studies addressing metabolism, side-effects and safety of NPs are desirable to gain maximum benefits of nanotherapeutics.


Subject(s)
Drug Delivery Systems , Nanostructures/administration & dosage , Animals , Biological Transport , Computer Simulation , Cytotoxins/administration & dosage , Cytotoxins/pharmacokinetics , Cytotoxins/toxicity , Humans , Mutagens/administration & dosage , Mutagens/pharmacokinetics , Mutagens/toxicity , Nanostructures/toxicity , Nanotechnology , Pharmaceutical Preparations/administration & dosage , Pharmaceutical Preparations/metabolism
19.
J Refract Surg ; 34(12): 817-823, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-30540364

ABSTRACT

PURPOSE: To evaluate the outcomes of a new posterior chamber phakic intraocular lens (IPCL; Care Group, Baroda, India) to correct myopia. METHODS: This prospective, observational case series included 30 eyes undergoing implantation of the IPCL for high myopia (> -8.00 diopters [D]). Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, vault, endothelial cell loss, and adverse events were evaluated 3 years after implantation of the IPCL for high myopia. RESULTS: The mean spherical equivalent decreased from -16.50 ± 5.62 D preoperatively to -0.89 ± 1.27 D at 3 years. The mean UDVA and CDVA were 0.38 ± 0.21 and 0.24 ± 0.09 logMAR. No eye lost any lines and 49% of eyes gained one line or more of CDVA. One eye (3.3%) developed anterior subcapsular cataract, but did not require cataract surgery at 3 years of follow-up. Two eyes (6.6%) developed a mild transient increase in intraocular pressure, which required topical medication only for 3 months. The percentage of endothelial cell loss at 3 years was 9.73% ± 6.72%. The IPCL vault tended to reduce with time, from a mean of 626.66 ± 188.98 µm at 1 month to 540.22 ± 210.76 µm at 3 years. No vision-threatening complications occurred. CONCLUSIONS: Implantation of the new posterior chamber phakic IOL is an effective alternative to correct high myopia, showing good outcomes at 3 years. [J Refract Surg. 2018;34(12):817-823.].


Subject(s)
Lens Implantation, Intraocular , Myopia, Degenerative/surgery , Phakic Intraocular Lenses , Adult , Corneal Endothelial Cell Loss/physiopathology , Female , Follow-Up Studies , Humans , Male , Myopia, Degenerative/physiopathology , Postoperative Complications , Prospective Studies , Prosthesis Design , Refraction, Ocular/physiology , Treatment Outcome , Visual Acuity/physiology , Young Adult
20.
J Ophthalmic Vis Res ; 13(4): 397-402, 2018.
Article in English | MEDLINE | ID: mdl-30479708

ABSTRACT

PURPOSE: To investigate the association of FOXE3-p.Ala170Ala (rs34082359) and PITX3-p.Ile95Ile (rs2281983) polymorphisms with congenital cataract and microphthalmia in a western Indian population. METHODS: FOXE3-p.Ala170Ala (c.510C>T) and PITX3-p.Ile95Ile (c.285C>T) polymorphisms were genotyped in 561 subjects consisting of 242 cases with congenital cataract, 52 with microphthalmia, and 267 controls using polymerase chain reaction-restriction fragment length polymorphism. Approximately 10% of samples were randomly sequenced for each single nucleotide polymorphism to confirm the genotypes. The prediction of mRNA secondary structure for polymorphism FOXE3-p.Ala170Ala and PITX3-p.Ile95Ile was performed. RESULTS: A significantly high frequency of T allele and a borderline significance in the frequency of TT genotype of FOXE3-p.Ala170Ala was observed in microphthalmia cases, as compared to controls [T allele: OR: [CI] = 1.8 [1.15-2.72], P = 0.0115; TT: OR [CI] = 2.9 [1.14-7.16], P = 0.0291). The frequency of CC genotype was significantly low in microphthalmia cases when compared to controls (CC: OR [CI] = 0.5 [0.24-0.86, P = 0.0150). There was no significant difference in the allele and genotype frequencies of PITX3-p.Ile95Ile between cases and controls. A slight free energy change was observed in the secondary structure of mRNA between the FOXE3-p.Ala170Ala C-allele (-917.60 kcal/mol) and T-allele (-916.80 kcal/mol) and between PITX3-p.Ile95Ile C-allele (-659.80 kcal/mol) and T-allele (-658.40 kcal/mol). CONCLUSION: The present findings indicate that FOXE3-p.Ala170Ala 'T' allele and 'TT' genotype could be predisposing factors for microphthalmia while 'CC' genotype might play a protective role against it. A reduction in the free energy change associated with FOXE3-p.Ala170Ala 'T' allele could further contribute towards disease risk.

SELECTION OF CITATIONS