Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Neurogastroenterol Motil ; 20(3): 371-8, 2014 Jul 31.
Article in English | MEDLINE | ID: mdl-24948129

ABSTRACT

BACKGROUND/AIMS: To report gastric emptying scintigraphy, normal values should be established for a specific protocol. The aim of this study was to provide normal gastric emptying values and determine factors affecting gastric emptying using Asian rice-based meal in healthy volunteers. METHODS: One hundred and ninety-two healthy volunteers were included at 7 tertiary care centers across Thailand. Gastric emptying scintigraphy was acquired in 45 degree left anterior oblique view immediately after ingestion of a 267 kcal steamed-rice with technetium-99m labeled-microwaved egg meal with 100 mL water for up to 4 hours. RESULTS: One hundred and eighty-nine volunteers (99 females, age 43 ± 14 years) completed the study. The medians (5-95th percentiles) of lag time, gastric emptying half time (GE T1/2) and percent gastric retentions at 2 and 4 hours for all volunteers were 18.6 (0.5-39.1) minutes, 68.7 (45.1-107.8) minutes, 16.3% (2.7-49.8%) and 1.1% (0.2-8.8%), respectively. Female volunteers had significantly slower gastric emptying compared to male (GE T1/2, 74 [48-115] minutes vs. 63 (41-96) minutes; P < 0.05). Female volunteers who were in luteal phase of menstrual cycle had significantly slower gastric emptying compared to those in follicular phase or menopausal status (GE T1/2, 85 [66-102] mintes vs. 69 [50-120] minutes or 72 [47-109] minutes, P < 0.05). All of smoking volunteers were male. Smoker male volunteers had significantly faster gastric emptying compared to non-smoker males (GE T1/2, 56 [44-80] minutes vs. 67 [44-100] minutes, P < 0.05). Age, body mass index and alcohol consumption habits did not affect gastric emptying values. CONCLUSIONS: A steamed-rice with microwaved egg meal was well tolerated by healthy volunteers. Gender, menstrual status and smoking status were found to affect solid gastric emptying.

2.
Epilepsy Behav ; 29(2): 386-9, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24074882

ABSTRACT

Bilateral temporal lobe hypometabolism (BTH) on (18)F-FDG PET brain scan is frequently seen in unilateral medial temporal lobe epilepsy (mTLE). This study aimed to identify the factors that influence BTH in patients with mTLE in order to minimize the significant factor(s) prior to performing a FDG-PET brain scan. Forty patients with unilateral mTLE who underwent (18)F-FDG PET scan for presurgical epilepsy workup were included. Bilateral temporal lobe hypometabolism of the anterior and medial parts of the temporal lobe was identified by a semiquantitative visual scale. Lateralization of TLE was identified by either intracranial EEG (22/40 cases) and/or improvement of seizure 2 years after temporal lobectomy (37/40 cases). The factors analyzed included basic demographic characteristics (age, sex, occupation, years of education, and handedness), history related to seizure (age at epilepsy onset and epilepsy duration, history of febrile seizure and head injury, frequency of seizure with impaired cognition in the last 3 months, presence of secondarily generalized tonic-clonic seizure, automatism side, presence of postictal confusion, and side of MRI temporal abnormality), information during video-EEG monitoring (clinical lateralization, interictal scalp EEG lateralization (interictal epileptiform discharge), and ictal scalp EEG lateralization), and information during the FDG-PET study (duration from the last seizure (≤2 days or >2 days), last seizure type, and the presence of slow waves or sharp waves during the FDG uptake period). Significant factors related to BTH were analyzed using multivariate analysis. Only the ≤2-day duration from the last seizure to the PET scan shows a significant effect (p=0.021) on BTH finding with 15 times greater incidence compared to a duration >2 days. Bilateral temporal lobe hypometabolism, which causes conflict in lateralizing the epileptogenic zone in temporal lobe epilepsy, can be avoided by performing PET scan more than 2 days after the last seizure.


Subject(s)
Epilepsy, Temporal Lobe/pathology , Epilepsy, Temporal Lobe/physiopathology , Fluorodeoxyglucose F18 , Functional Laterality/physiology , Temporal Lobe/diagnostic imaging , Adult , Electroencephalography , Epilepsy, Temporal Lobe/diagnostic imaging , Female , Humans , Male , Middle Aged , Retrospective Studies , Statistics, Nonparametric , Temporal Lobe/metabolism , Tomography Scanners, X-Ray Computed , Tomography, Emission-Computed
3.
J Med Assoc Thai ; 96(6): 696-702, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23951827

ABSTRACT

OBJECTIVE: Papillary thyroid cancer has a high prevalence of cervical nodal metastasis. There is no "gold standard" imaging for pre-operative diagnosis. The aim of the present study was to assess the accuracy of pre-operative 99mTc-MBI SPECT/CT in diagnosis of cervical nodal metastasis in patients with papillary thyroid cancer MATERIAL AND METHOD: Fifteen patients were performed 99Tc-MlBI SPECT/CT pre-operatively. Either positive pathological report of neck dissection or positive post-treatment I-131 whole body scan with SPECT/CT of neck was concluded for definite neck metastasis. The PPV, NPV, and accuracy of 99mTc-MIBI SPECT/CT were analyzed. RESULTS: The PPV NPV and accuracy were 80%, 88.89%, and 85.71%, respectively. 99mTc-MIBI SPECT/CT could localize the abnormal lymph nodes groups correctly in most cases when compared with pathological results. However the authors found one false positive case with caseating granulomatous lymphadenitis and one false negative case with positive post-treatment 1-131 whole body scan with SPECT/CT of neck on cervical nodes zone II and IV CONCLUSION: 99mTc-MIBI SPECT/CTseem promising for pre-operative staging of cervical nodal involvement in patients with papillary thyroid cancer without the need of using iodinated contrast that may complicate subsequence 1-131 treatment. However, false positive result in granulomatous inflammatory nodes should be aware of especially in endemic areas. 99mTc-MIBI SPECT/CT scan shows a good result when compared with previous study of CT or MRI imaging. The comparative study between different imaging modality and the extension of neck dissection according to MIBI result seems interesting.


Subject(s)
Carcinoma/secondary , Carcinoma/surgery , Lymph Nodes/pathology , Radiopharmaceuticals , Technetium Tc 99m Sestamibi , Thyroid Neoplasms/secondary , Thyroid Neoplasms/surgery , Tomography, Emission-Computed, Single-Photon , Adult , Aged , Carcinoma, Papillary , Female , Humans , Lymphatic Metastasis , Male , Middle Aged , Neck , Neck Dissection , Pilot Projects , Predictive Value of Tests , Thyroid Cancer, Papillary , Thyroidectomy , Young Adult
4.
J Neurogastroenterol Motil ; 16(4): 401-6, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21103421

ABSTRACT

BACKGROUND/AIMS: Technetium-99m ((99m)Tc)-pertechnetate single photon emission computed tomography (SPECT) allows non-invasive measurement of gastric accommodation (GA) and has been reported to provide the results comparable to the gold standard barostat. The reproducibility of the test when it is performed at different time of the day is not known. The aim of this study was to assess the reproducibility of GA measurement by (99m)Tc-pertechnetate SPECT at the same and different time of the day. METHODS: Three GA studies were performed in each of 20 healthy volunteers (9 males, age 35 ± 9 years), 2 studies in the morning and 1 study in the afternoon. Each study was performed on separate days at least 3 days apart, in random order. The fasting gastric scintigraphy images were acquired using SPECT at 30 minutes after iv (99m)Tc-pertechnetate. Then, the scintigraphic images were acquired 50 minutes after liquid meal (250 mL, Ensure®) ingestions. Gastric volumes were calculated from transaxial gastric images using Image J software. The GA was defined as the maximum postprandial gastric volume minus fasting gastric volume. RESULTS: GA measurement by SPECT show good reproducibility at both the same and different time of the day. The intraclass correlation coefficients of GA results for the same time, the first different time and the second different time studies were 0.681, 0.630 and 0.774, respectively, and the intra-subject coefficients of variation were 13.9%, 14.1% and 8.7%, respectively. CONCLUSIONS: GA measurement by (99m)Tc-pertechnetate SPECT shows good reproducibility at both the same and different time of the day. This result suggests that the schedule time does not appear to extremely affect the gastric accommodation value.

SELECTION OF CITATIONS
SEARCH DETAIL
...