1.
Int J Mol Sci ; 24(8)2023 Apr 14.
Article in English | MEDLINE | ID: mdl-37108443

ABSTRACT

The causes of heart valve bioprosthetic calcification are still not clear. In this paper, we compared the calcification in the porcine aorta (Ao) and the bovine jugular vein (Ve) walls, as well as the bovine pericardium (Pe). Biomaterials were crosslinked with glutaraldehyde (GA) and diepoxide (DE), after which they were implanted subcutaneously in young rats for 10, 20, and 30 days. Collagen, elastin, and fibrillin were visualized in non-implanted samples. Atomic absorption spectroscopy, histological methods, scanning electron microscopy, and Fourier-transform infrared spectroscopy were used to study the dynamics of calcification. By the 30th day, calcium accumulated most intensively in the collagen fibers of the GA-Pe. In elastin-rich materials, calcium deposits were associated with elastin fibers and localized differences in the walls of Ao and Ve. The DE-Pe did not calcify at all for 30 days. Alkaline phosphatase does not affect calcification since it was not found in the implant tissue. Fibrillin surrounds elastin fibers in the Ao and Ve, but its involvement in calcification is questionable. In the subcutaneous space of young rats, which are used to model the implants' calcification, the content of phosphorus was five times higher than in aging animals. We hypothesize that the centers of calcium phosphate nucleation are the positively charged nitrogen of the pyridinium rings, which is the main one in fresh elastin and appears in collagen as a result of GA preservation. Nucleation can be significantly accelerated at high concentrations of phosphorus in biological fluids. The hypothesis needs further experimental confirmation.


Subject(s)
Bioprosthesis , Calcinosis , Heart Valve Diseases , Heart Valve Prosthesis , Rats , Animals , Cattle , Swine , Elastin , Calcium , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Calcinosis/pathology , Glutaral , Collagen , Phosphorus , Pericardium/pathology
2.
Biomedicines ; 10(9)2022 Sep 08.
Article in English | MEDLINE | ID: mdl-36140329

ABSTRACT

This paper presents pioneering results on the evaluation of noble metal film hetero-structures to improve some functional characteristics of carbon-based implant materials: carbon-composite material (CCM) and carbon-fiber-reinforced polyetheretherketone (CFR-PEEK). Metal-organic chemical vapor deposition (MOCVD) was successfully applied to the deposition of Ir, Pt, and PtIr films on these carriers. A noble metal layer as thin as 1 µm provided clear X-ray imaging of 1−2.5 mm thick CFR-PEEK samples. The coated and pristine CCM and CFR-PEEK samples were further surface-modified with Au and Ag nanoparticles (NPs) through MOCVD and physical vapor deposition (PVD) processes, respectively. The composition and microstructural features, the NPs sizes, and surface concentrations were determined. In vitro biological studies included tests for cytotoxicity and antibacterial properties. A series of samples were selected for subcutaneous implantation in rats (up to 3 months) and histological studies. The bimetallic PtIr-based heterostructures showed no cytotoxicity in vitro, but were less biocompatible due to a dense two-layered fibrous capsule. AuNP heterostructures on CFR-PEEK promoted cell proliferation in vitro and exhibited a strong inhibition of bacterial growth (p < 0.05) and high in vitro biocompatibility, especially Au/Ir structures. AgNP heterostructures showed a more pronounced antibacterial effect, while their in vivo biocompatibility was better than that of the pristine CFR-PEEK, but worse than that of AuNP heterostructures.

3.
Biomedicines ; 9(8)2021 Jul 21.
Article in English | MEDLINE | ID: mdl-34440054

ABSTRACT

This work is aimed at developing the modification of the surface of medical implants with film materials based on noble metals in order to improve their biological characteristics. Gas-phase transportation methods were proposed to obtain such materials. To determine the effect of the material of the bottom layer of heterometallic structures, Ir, Pt, and PtIr coatings with a thickness of 1.4-1.5 µm were deposited by metal-organic chemical vapor deposition (MOCVD) on Ti6Al4V alloy discs. Two types of antibacterial components, namely, gold nanoparticles (AuNPs) and discontinuous Ag coatings, were deposited on the surface of these coatings. AuNPs (11-14 nm) were deposited by a pulsed MOCVD method, while Ag films (35-40 nm in thickness) were obtained by physical vapor deposition (PVD). The cytotoxic (24 h and 48 h, toward peripheral blood mononuclear cells (PBMCs)) and antibacterial (24 h) properties of monophase (Ag, Ir, Pt, and PtIr) and heterophase (Ag/Pt, Ag/Ir, Ag/PtIr, Au/Pt, Au/Ir, and Au/PtIr) film materials deposited on Ti-alloy samples were studied in vitro and compared with those of uncoated Ti-alloy samples. Studies of the cytokine production by PBMCs in response to incubation of the samples for 24 and 48 h and histological studies at 1 and 3 months after subcutaneous implantation in rats were also performed. Despite the comparable thickness of the fibrous capsule after 3 months, a faster completion of the active phase of encapsulation was observed for the coated implants compared to the Ti alloy analogs. For the Ag-containing samples, growth inhibition of S. epidermidis, S. aureus, Str. pyogenes, P. aeruginosa, and Ent. faecium was observed.

4.
Mater Sci Eng C Mater Biol Appl ; 118: 111473, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33255052

ABSTRACT

Bioprosthetic heart valves made from bovine pericardium (BP) and porcine pericardium (PP) preserved with glutaraldehyde (GA) are commonly used in valve surgeries but prone to calcification in many patients. In this study, we compared BP and PP preserved with GA, ethylene glycol diglycidyl ether (DE), and 1,2,3,4,6-penta-O-{1-[2-(glycidyloxy)ethoxy]ethyl}-d-glucopyranose (PE). We studied the stabilities of DE and PE in preservation media along with the amino acid (AA) compositions, Fourier-transform infrared spectra, mechanical properties, surface morphologies, thermal stability, calcification, and the cytocompatibility of BP and PP treated with 0.625% GA, 5% DE, 2% PE, and alternating 5% DE and 2% PE for 3 + 11 d and 10 + 10 d, respectively. Both epoxides were stable in the water-buffer solutions (pH 7.4). DE provided high linkage densities in BP and PP owing to reactions with Hyl, Lys, His, Arg, Ser, and Tyr. PE reacted weakly with these AAs but strongly with Met. High cross-linking density obtained using the 10 d + 10 d method provided satisfactory thermal stability of biomaterials. The epoxy preservations improved cytocompatibility and resistance to calcification. PE enhanced the stress/strain properties of the xenogeneic pericardia, perhaps by forming nanostructures that were clearly visualised in BP using scanning electron microscopy. The DE + PE combination, in an alternating cross-linking manner, thus constitutes a promising option for developing bioprosthetic pericardia.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Animals , Cattle , Cross-Linking Reagents , Glutaral , Humans , Pericardium , Swine
5.
J Biomed Mater Res A ; 108(7): 1579-1588, 2020 05.
Article in English | MEDLINE | ID: mdl-32176416

ABSTRACT

This study evaluated the ability of bisphosphonates (BPAs) of different molecular structures to mitigate the calcification of porcine aortic wall (PAW) and bovine jugular vein wall (BJVW). Tissues cross-linked with glutaraldehyde (GA) or diepoxide (DE) were modified with pamidronic acid (PAM), alendronic acid (ALE), neridronic acid (NER) (type 1 BPAs); 2-(2'-carboxyethylamino)ethylidene-1,1-bisphosphonic acid (CEABA), 2-(5-carboxypentylamino)ethylidene-1,1-bisphosphonic acid (CPABA) (type 2); and zoledronic acid (ZOL) (type 3). After implanting the tissue samples subcutaneously in 100 rats, calcification was examined using atomic absorption spectrophotometry (60-day explants) and light microscopy after von Kossa staining (10- and 30-day explants). The calcium contents in GA-BJVW and GA- and DE-PAW increased up to 100-120 mg/g after 60 days, while being 3 times lower in DE-BJVW. In modified and nonmodified PAW samples, calcium phosphates appeared by day 10 and were associated with elastic fibers and devitalized cellular elements. In all groups of BJVW samples, mineralization began in elastic fibers near the subendothelial layer. In addition, calcified collagen was found in the GA-BJVW samples. Minimal calcification was found in GA-PAW treated with type 1 BPAs and CEABA. For DE-PAW and GA-BJVW, the calcium level significantly decreased with PAM and CEABA. Meanwhile, ALE and NER were effective for DE-BJVW.


Subject(s)
Biocompatible Materials/adverse effects , Bioprosthesis/adverse effects , Calcinosis/etiology , Diphosphonates/administration & dosage , Elastin/adverse effects , Animals , Biocompatible Materials/chemistry , Calcinosis/prevention & control , Cattle , Diphosphonates/chemistry , Diphosphonates/therapeutic use , Elastin/chemistry , Swine