Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-37107716

ABSTRACT

Surfaces have been implicated in the transmission of pathogens in hospitals. This study aimed to assess the effectiveness of an usnic-acid-containing self-decontaminating coating in reducing microbial surface contamination in tertiary-care hospitals. Samples were collected from surfaces 9 days before coating application, and 3, 10, and 21 days after its application (phases 1, 2, 3, and 4, respectively). Samples were tested for bacteria, fungi, and SARS-CoV2. In phase 1, 53/69 (76.8%) samples tested positive for bacteria, 9/69 (13.0%) for fungi, and 10/139 (7.2%) for SARS-CoV-2. In phase 2, 4/69 (5.8%) samples tested positive for bacteria, while 69 and 139 samples were negative for fungi and SARS-CoV-2, respectively. In phase 3, 3/69 (4.3%) samples were positive for bacteria, 1/139 (0.7%) samples tested positive for SARS-CoV-2, while 69 samples were negative for fungi. In phase 4, 1/69 (1.4%) tested positive for bacteria, while no fungus or SARS-CoV-2 were detected. After the coating was applied, the bacterial load was reduced by 87% in phase 2 (RR = 0.132; 95% CI: 0.108-0.162); 99% in phase 3 (RR = 0.006; 95% CI: 0.003-0.015); and 100% in phase 4 (RR = 0.001; 95% CI: 0.000-0.009). These data indicate that the usnic-acid-containing coating was effective in eliminating bacterial, fungal, and SARS-CoV-2 contamination on surfaces in hospitals.Our findings support the benefit ofan usnic-acid-containing coating in reducing the microbial load on healthcare surfaces.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/epidemiology , COVID-19/prevention & control , RNA, Viral , Tertiary Care Centers
2.
Am J Infect Control ; 49(11): 1435-1437, 2021 11.
Article in English | MEDLINE | ID: mdl-34455029

ABSTRACT

Contamination of surfaces has been implicated in transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We tested by real-time PCR for SARS-CoV-2 contamination environmental samples from three hospitals during the peak of the third pandemic wave. Overall, 19 of 463 (4.1%) samples tested positive: 12 of 173 (6.9%) samples from a COVID-19 hospital, 3 of 177 (1.7%) samples from a non-COVID-19 hospital, and 4 of 113 (3.5%) samples from a pediatric hospital with dedicated COVID-19 clinics. Most positive samples originated from emergency departments (EDs) (47.3%) and the intensive care units (ICUs) (26.3%) of the COVID-19 hospital. Positive samples belonged almost exclusively (18/19) to the highly transmissible B.1.1.7 cluster, that might explain environmental contamination at this stage of the pandemic. The frequency and efficiency of disinfection in high-risk patient areas, such as EDs and ICUs, should be reinforced, especially during this period where highly transmissible variants of concern are widespread.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19/epidemiology , Humans , Pandemics , Tertiary Care Centers
3.
BMC Public Health ; 6: 306, 2006 Dec 18.
Article in English | MEDLINE | ID: mdl-17176469

ABSTRACT

BACKGROUND: Management of environmental health issues is an integral part of public health systems. An active integrated environmental health surveillance and response system was developed for the Athens Olympics to monitor and prevent exposure to environmental hazards. The potential for permanent implementation of the program was examined. METHODS: The environmental health surveillance and response system included standardization, computerization and electronic transmission of data concerning environmental inspections of 17 site categories (restaurants, swimming pools etc) of public health interest, drinking and recreational water examinations and suggested corrective actions. The Olympic Planning Unit integrated and centrally managed data from 13 public health agencies, recommended, supervised and coordinated prompt corrective actions. Methods used to test the effectiveness of the program were the assessment of water quality test and inspection results trends over time using linear regression and epidemiological surveillance findings. RESULTS: Between January 2003 and September the 30th, 2004, 196 inspectors conducted 8562 inspections, collected 5024 water samples and recommended 17 027 corrective actions. In 10 cruise ships used as floating hotels inspectors conducted 10 full inspections, 2 re-inspections, and 27 follow-up inspections. Unsatisfactory inspection results (r = 0.44, p < 0.0001) and positive water quality tests (r = 0.39, p < 0.001) presented an overall decrease trend over time. In August, 2003, an outbreak of salmonellosis was linked to a hotel restaurant which accommodated athletes during a test event. CONCLUSION: Lessons learned for future events include timely implementation and installation of communication processes, and rapid and coordinated response to unsatisfactory inspection results. Routine national programs need to adopt enhanced environmental health surveillance aimed at public health decision-making, but with a different perspective.


Subject(s)
Anniversaries and Special Events , Environmental Monitoring/methods , Population Surveillance/methods , Risk Management/organization & administration , Sports , Accident Prevention , Communicable Disease Control , Emergency Medical Service Communication Systems , Foodborne Diseases/prevention & control , Greece , Health Planning Guidelines , Health Services Needs and Demand , Humans , Public Health Administration/standards , Restaurants/standards , Risk Management/standards , Swimming Pools/standards , Water Supply/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...