Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-33992977

ABSTRACT

Natural and synthetic steroid hormones are chronically released into aquatic spheres. Whereas knowledge on their combined mode of action and the cocktail effect are needed, only few multi-class methods address the challenge of their trace quantification in surface waters. The current study describes a sensitive multi-residue analytical strategy aiming to quantify 23 steroid hormones belonging to androgens, estrogens, glucocorticoids and progestogens in whole surface waters. The procedure relies on a two-step solid-phase extraction followed by an ultra-performance liquid chromatography separation coupled to tandem mass spectrometry detection (UPLC-MS/MS). Isotope dilution was implemented when possible in order to ensure the reliability of the measurement. The procedure was optimized toward the reliable quantification of the 23 target compounds at the predicted no-effect concentrations when existing or below the ng L-1 level. Satisfactory absolute global recoveries ≥ 77% were obtained for almost all compounds (21 out of 23) in intermediate precision conditions. Measurement errors were comprised between -27% and +17% for the great majority of compounds (21 out of 23) with standard deviations < 20% in intermediate precision conditions. Despite signal suppression was observed in water samples, satisfactory limits of quantification were achieved, ranging from 0.035 ng L-1 for 17alpha-ethinylestradiol to 1 ng L-1 for 6beta-hydroxycortisol and 6beta-hydroxydexamethasone. Abiotic stability was demonstrated for the great majority of target compounds (22 out of 23) in reference water samples stored at 4 ± 3 °C during 48 h, driving our sampling strategy. To demonstrate its fitness for purpose, the procedure was implemented in a preliminary monitoring survey of Belgian surface waters. As a result, 6 out of 23 target compounds were detected or quantified, showing a contamination by some estrogens and glucocorticoids at levels ranging from 0.1 to 0.9 ng L-1.


Subject(s)
Endocrine Disruptors/analysis , Environmental Monitoring/methods , Hormones/analysis , Water Pollutants, Chemical/analysis , Water/chemistry , Chromatography, High Pressure Liquid , Limit of Detection , Reproducibility of Results , Solid Phase Extraction , Tandem Mass Spectrometry , Water Supply
2.
Article in English | MEDLINE | ID: mdl-27436277

ABSTRACT

The present work describes a multi-residue SPE-UPLC-MS/MS method aiming at the characterization of 68 compounds in natural waters, including parent compounds as well as their major metabolites and glucuronide conjugates. Development was conducted toward the quantitative determination of a broad range of analytes belonging to different class of psychotropic drugs such as benzodiazepines, antidepressants, stimulants, opiates and opioids, anticonvulsants, anti-dementia drugs, analgesic and anti-inflammatory drugs (as anthropic indicators) in the low ngL-1 range of concentration. Satisfactory extraction recoveries >70% were obtained for the majority of analytes (49 out of 68) allowing low limits of quantification. LOQ ranged between 0.1 and 17.8ngL-1 and were lower than 5ngL-1 for 94% of investigated analytes. Furthermore, addition of 25 isotopic labeled standards allowed to ensure reliability of the optimized method. Quantification errors were typically below 15% with relative standard variations <10% in intermediate precision conditions. Finally, the developed method was implemented in natural waters; sampling campaigns were conducted in the Seine River as a demonstration of the applicability and adequation of the method for its purpose. As a result, 48 out of 68 analytes were identified or quantified; some of them like memantine, rivastigmine, zolpidem 4-phenyl-carboxylic acid, zolpidem 6-carboxylic acid for one of the first time in surface waters. Among investigated psychotropic compounds and metabolites, tramadol, codeine, oxazepam, venlafaxine, O-desmethylvenlafaxine, gabapentin, carbamazepine and 10,11-dihydro-10,11-dihydroxycarbamazepine were found to be the most abundant.


Subject(s)
Chromatography, High Pressure Liquid/methods , Illicit Drugs/analysis , Psychotropic Drugs/analysis , Solid Phase Extraction/methods , Tandem Mass Spectrometry/methods , Water Pollutants, Chemical/analysis , Environmental Monitoring/methods , Glucuronides/analysis , Limit of Detection , Rivers/chemistry
3.
Talanta ; 146: 138-47, 2016.
Article in English | MEDLINE | ID: mdl-26695245

ABSTRACT

The present work describes the development and validation of a reference method conducted at the French National Institute of Metrology (LNE) for the quantitative determination of psychoactive compounds in the dissolved fraction of surface waters. More specifically an isotope dilution-SPE-LC-MS/MS based method has been implemented for the characterization of a broad range of analytes belonging to different classes of psychotropic drugs such as benzodiazepines, antidepressants, stimulants, opiates and opioids, anticonvulsants, anti-dementia drugs, analgesics as well as the anti-inflammatory drug diclofenac in the low ng L(-1) range of concentration. Full validation of the method was performed following procedures described by the French standard NF T90-210. Limits of quantification between 0.14 and 3.54 ng L(-1) were obtained. Method recoveries from 71 to 123% were observed with standard deviation below 10% in intermediate precision conditions. Accuracy was determined for every compound: measurement errors were between -4 and +1% and standard deviations in intermediate precision conditions were included within a 1-9% interval. Finally, measurement uncertainties were evaluated following the Guide to the expression of uncertainty in measurement (GUM). Expanded uncertainties (k=2) ranged from 2% for carbamazepine, EDDP (2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine) and venlafaxine to 17% for diazepam. The validated method was implemented to Seine river surface waters demonstrating its fitness for purpose. All compounds were detected and 22 out of 25 analytes were quantified. More specifically, measured concentration ranged from 0.39 ng L(-1) for MDMA (3,4-methylene-dioxy-N-methylamphetamine) to 182 ng L(-1) for gabapentine.


Subject(s)
Chromatography, Liquid/methods , Drug Residues/analysis , Drug Residues/isolation & purification , Solid Phase Extraction/methods , Tandem Mass Spectrometry/methods , Uncertainty , Water/chemistry , Isotopes , Limit of Detection , Water Pollutants, Chemical/analysis , Water Pollutants, Chemical/isolation & purification
4.
Anal Bioanal Chem ; 398(5): 2265-77, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20835870

ABSTRACT

A certified matrix reference material (CRM) for the measurement of benzene in ambient air has been developed at Laboratoire National de Métrologie et d'Essais. The production of these CRMs was conducted using a gravimetric method fully traceable to the International System of Units. The CRMs were prepared by sampling an accurate mass of a gaseous primary reference material of benzene, using a high-precision laminar flowmeter and a mass flow controller, with a PerkinElmer sampler filled with Carbopack™ X sorbent. The relative standard deviations obtained for the preparation of a batch of 20 tubes loaded with 500 ng of benzene were below 0.2%. Each CRM is considered independent from the others and with its own certified value and an expanded uncertainty estimated to be within 0.5%, lower than the uncertainties of benzene CRMs already available worldwide. The stability of these materials was also established up to 12 months. These CRMs were implemented during proficiency testing, to evaluate the analytical performances of seven French laboratories involved in benzene air monitoring.


Subject(s)
Air Pollutants/analysis , Benzene/analysis , Environmental Monitoring/methods , Environmental Monitoring/standards , Absorption , Chromatography, Gas , Reference Standards
SELECTION OF CITATIONS
SEARCH DETAIL
...