Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Anal ; 5(3): 190-199, 2015 Jun.
Article in English | MEDLINE | ID: mdl-29403931

ABSTRACT

An analytical method based on solid phase extraction was developed and validated for analysis of adefovir in human plasma. Adefovir-d4 was used as an internal standard and Synergi MAX RP80A (150 mm×4.6 mm, 4 µm) column provided the desired chromatographic separation of compounds followed by detection with mass spectrometry. The method used simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode. The calibration curves were linear over the range of 0.50-42.47 ng/mL with the lower limit of quantitation validated at 0.50 ng/mL. Matrix effect was assessed by post-column infusion experiment to monitor phospholipids and post-extraction addition experiment was performed. The degree of matrix effect for adefovir was determined as 7.5% and ion-enhancement in five different lots of human plasma was 7.1% and had no impact on study samples analysis with 4.5 min run time. The intra- and inter-day precision values were within 7.7% and 7.8%, respectively, for adefovir at the lower limit of quantification level. Validated bioanalytical method was successfully applied to clinical sample analysis.

2.
Sci Pharm ; 82(3): 585-600, 2014.
Article in English | MEDLINE | ID: mdl-25853070

ABSTRACT

A reliable, simple, and robust liquid chromatography-tandem mass spectro-metric (LC-MS/MS) method has been developed and validated that employs solid-phase extraction for the simultaneous estimation of amlodipine and valsartan in human K3EDTA plasma using amlodipine-d4 and valsartan-d9 as internal standards. Chromatographic separation of amlodipine and valsartan was achieved on the Luna C18 (2)100A (150 × 4.6 mm, 5 µm) column using acetonitrile: 5 mM ammonium formate solution (80:20, v/v) as the mobile phase at a flow rate of 0.8 mL/min in isocratic mode. Quantification was achieved using an electrospray ion interface operating in positive mode, under multiple reaction monitoring (MRM) conditions. The assay was found to be linear over the range of 0.302-20.725 ng/mL for amlodipine and 6.062-18060.792 ng/mL for valsartan. The method has shown good reproducibility, as intra- and interday precisions were within 10% and accuracies were within 8% of nominal values for both analytes. The method was successfully applied for the bioequivalence study of amlodipine and valsartan after oral administration of a fixed dose of the combination. Additionally, as required by the current regulatory bodies, incurred sample reanalysis was performed and found to be acceptable.

3.
Article in English | MEDLINE | ID: mdl-22766230

ABSTRACT

Metaxalone is a skeletal muscle relaxant, an approved drug for pain relief. Published bioanalytical methods lacked detailed stability evaluation in blood and plasma. An accurate, precise, high-throughput tandem mass spectroscopic method has been developed and validated. Following solid phase extraction (SPE), metaxalone and the internal standard metaxalone-d(3) were extracted from an aliquot of 200 µL of human plasma. Chromatographic separation achieved on an Ascentis Express C18 column (50 mm × 4.6 mm i.d., 2.7 µm particle size) with mobile phase is a mixture of 10mM ammonium acetate buffer (pH 4.5)-methanol-acetonitrile (20:50:30, v/v/v), at an isocratic flow rate of 0.7 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. The mass transitions of metaxalone and metaxalone-d(3) were m/z 222.3→161.2 and m/z 225.3→163.3, respectively. The linear calibration curves were obtained in the concentration range of 0.105-10.081 µg/mL (r(2)≥0.99) with a lower limit of quantification (LLOQ) of 0.105 µg/mL. The intra- and inter-day precisions and relative error were all within 6%. Despite achieving high mean recovery (>78%), no interference peaks or matrix effects were observed. Detailed stability exercises including drug stability in blood, hemolyzed, lipemic and normal plasma were conducted to extend the method applicability in vast majority of clinical studies using 800 mg metaxalone extended release oral dosage form.


Subject(s)
Chromatography, Liquid/methods , High-Throughput Screening Assays/methods , Oxazolidinones/blood , Tandem Mass Spectrometry/methods , Adult , Drug Stability , Hemolysis , Humans , Hyperlipidemias/blood , Linear Models , Male , Oxazolidinones/chemistry , Reproducibility of Results , Sensitivity and Specificity , Solid Phase Extraction
SELECTION OF CITATIONS
SEARCH DETAIL
...