ABSTRACT

Effective real-time monitoring is the key to understanding and tackling the issue of pharmaceutical contamination of water. This research demonstrates the utility of an alumina nanochannel-based electrochemical sensor platform for the detection of ibuprofen in water derived from various sources. Our results indicate that the sensor is highly sensitive with a limit of detection at 0.25 pg mL(-1). The novel sensor described here has potential for application as a simple, rapid, inexpensive and highly reliable method for real-time environmental water quality assessment.


Subject(s)
Environmental Monitoring/instrumentation , Pharmaceutical Preparations/analysis , Water Pollutants, Chemical/analysis , Electrochemical Techniques , Environmental Monitoring/methods