1.
J Chromatogr A ; 1518: 104-110, 2017 Oct 06.
Article in English | MEDLINE | ID: mdl-28882340

ABSTRACT

An open tubular (OT) sample preparation/separation platform was developed. A multi-channel polymer layer open tubular (mPLOT) solid phase extraction (SPE) column was prepared by wall-coating the 126 channels (8µm inner diameter (ID) each) of a crystal fiber capillary with an organic polymer, namely poly(styrene-co-octadecene-co-divinylbenzene) (PS-OD-DVB). The mPLOT SPE was coupled on-line with a 10µm×2m poly(styrene-co-divinylbenzene) (PS-DVB) OT liquid chromatography column with nanospray mass spectrometry (OTLC-MS). Compared to using monolithic/particle-packed SPEs, mPLOT-SPE-OTLC allowed both fast loading and sufficient refocusing on the OT analytical column of small model compounds (sulfonamides≈300Da). Using automatic filtration/filter back-flushing (AFFL) plumbing, the mPLOT SPE column gave a constant and low back-pressure ≈35bar at 0.5µL/min. Surprisingly large sample volumes (10µL) were possible to be injected using a 12cm mPLOT.


Subject(s)
Chemistry Techniques, Analytical/instrumentation , Chromatography, Liquid , Mass Spectrometry , Solid Phase Extraction/instrumentation , Polystyrenes/chemistry , Polyvinyls/chemistry
2.
J Chromatogr A ; 1498: 111-119, 2017 May 19.
Article in English | MEDLINE | ID: mdl-28385266

ABSTRACT

Self-preparation of nano liquid chromatography (nLC) columns has advantages regarding cost and flexibility. For targeted proteomics, we evaluated several approaches for particle-packing nLC columns and manufacturing fritless silica-based monolithic trap columns (50µm inner diameter). Our preferred approach for nLC column preparation was to magnetically stir Accucore core shell particles (C18 stationary phase) in ACN/water (80/20, v/v) suspensions during pressure-driven filling of polymer-fritted standard fused silica capillaries. The columns were ready for use about one hour after preparation had begun. They had comparable peak capacities (peptides) to commercial columns, and satisfactory within/between-column retention time repeatability, suited for targeted proteomics. Packing with commercial capillary housings/nanospray emitters did not improve performance compared to packing with in-house fritted stock fused silica capillary tubing. For trap columns, several recipes for narrow bore silica-based monolithic columns were evaluated, and we found the recipe by Zou et al. (2005) to be reproducible. Compared to the standard C18 trap column for Accucore nLC columns, monolith trap columns (C8 stationary phase) significantly reduced peak widths. The readily prepared in-house columns were used for targeted detection of the enzyme CYP27A1 in cancer cells, which is associated with proliferation and metastasis of breast cancer.


Subject(s)
Chromatography, High Pressure Liquid/methods , Nanoparticles/chemistry , Peptides/analysis , Proteomics/methods , Silicon Dioxide/chemistry , Cell Line, Tumor , Cholestanetriol 26-Monooxygenase/analysis , Cholestanetriol 26-Monooxygenase/isolation & purification , Humans , Mass Spectrometry , Microscopy, Electron, Scanning , Peptides/isolation & purification , Pressure
3.
J Steroid Biochem Mol Biol ; 169: 22-28, 2017 05.
Article in English | MEDLINE | ID: mdl-26877254

ABSTRACT

Exosomes from cancer cells are rich sources of biomarkers and may contain elevated levels of lipids of diagnostic value. 27-Hydroxycholesterol (27-OHC) is associated with proliferation and metastasis in estrogen receptor positive (ER+) breast cancer. In this study, we investigated the levels of 27-OHC, and other sidechain-hydroxylated oxysterols in exosomes. To study both cytoplasmic and exosomal oxysterol samples of limited size, we have developed a capillary liquid chromatography-mass spectrometry platform that outperforms our previously published systems regarding chromatographic resolution, analysis time and sensitivity. In the analyzed samples, the quantified level of cytoplasmic 27-OHC using this platform fitted with mRNA levels of 27-OHC's corresponding enzyme, CYP27A1. We find clearly increased levels of 27-OHC in exosomes (i.e., enrichment) from an ER+ breast cancer cell line (MCF-7) compared to exosomes derived from an estrogen receptor (ER-) breast cancer cell line (MDA-MB-231) and other control exosomes (non-cancerous cell line (HEK293) and human pooled serum). The exosomal oxysterol profile did not reflect cytoplasmic oxysterol profiles in the cells of origin; cytoplasmic 27-OHC was low in ER+ MCF-7 cells while high in MDA-MB-231 cells. Other control cancer cells showed varied cytoplasmic oxysterol levels. Hence, exosome profiling in cancer cells might provide complementary information with the possibility of diagnostic value.


Subject(s)
Breast Neoplasms/metabolism , Estrogen Receptor alpha/metabolism , Exosomes/chemistry , Hydroxycholesterols/chemistry , Cell Line, Tumor , Chromatography, Liquid , Cytoplasm/metabolism , Female , HEK293 Cells , Humans , MCF-7 Cells , Mass Spectrometry , Reproducibility of Results
4.
Future Sci OA ; 2(2): FSO119, 2016 Jun.
Article in English | MEDLINE | ID: mdl-28031966

ABSTRACT

AIM: We compared four commonly used, commercially available reverse phase nanoLC columns for identification/determination of Wnt/ß-catenin-related pathway proteins. MATERIALS & METHODS: The columns were: Chromolith® (silica monolith; Merke Millipore, MA, USA), PepMap™ (porous particles; Thermo Fisher Scientific, MA, USA), Accucore™ (solid core particles; Thermo Fisher Scientific) and PepSwift™ (organic monolith; Thermo Fisher Scientific). RESULTS: The peak capacity of the columns varied from 100 (Pepswift) to 190 (Accucore) (for 30 min gradients). All columns enabled identification/detection of GSK3ß and ß-catenin in the complex samples. However, even the columns with higher peak capacities could not enable detection of the somewhat less abundant proteins AXIN2 and TNKS2. The monoliths were more prone to retention time instability when sample complexity increased. CONCLUSION: We find that commercial nanoLC columns, although featuring different morphologies and peak capacities, provided surprisingly few practical differences for relatively fast, targeted determination of proteins.

5.
J Pharm Biomed Anal ; 120: 106-11, 2016 Feb 20.
Article in English | MEDLINE | ID: mdl-26719981

ABSTRACT

Amicon(®) Ultra centrifugal filters were critically evaluated for various sample preparations, namely (a) proteome fractionation, (b) sample cleanup prior to liquid chromatography mass spectrometry (LC-MS) measurement of small molecules in cell lysate, and (c) separating drug-loaded nanoparticles and released drugs for accurate release profiling in biological samples. (a) Filters of supposedly differing molar mass (MM) selectivity (10, 30, 50 and 100K) were combined to attempt fractionation of samples of various complexity and concentration. However, the products had surprisingly similar MM retentate/filtrate profiles, and the filters were unsuited for proteome fractionation. (b) Centrifugal filtration was the only clean-up procedure in a FDA-guideline validated LC-MS method for determining anti-tuberculosis agents rifampicin and thioridazine in macrophage cell lysate. An additional organic solvent washing step (drug/protein-binding disruption) was required for satisfactory recovery. (c) The centrifugation filters are well suited for separating drugs and nanoparticles in simple aqueous solutions, but significantly less so for biological samples, as common drug-protein binding disruptors can dissolve NPs or be incompatible with LC-MS instrumentation.


Subject(s)
Nanoparticles/chemistry , Pharmaceutical Preparations/chemistry , Proteins/chemistry , Centrifugation/methods , Chemical Fractionation/methods , Chromatography, Liquid/methods , Molecular Weight , Proteome/chemistry , Solvents/chemistry , Tandem Mass Spectrometry/methods
6.
Bioanalysis ; 7(14): 1799-815, 2015.
Article in English | MEDLINE | ID: mdl-26270786

ABSTRACT

In proteomics, nano-LC is arguably the most common tool for separating peptides/proteins prior to MS. The main advantage of nano-LC is enhanced sensitivity, as compounds enter the MS in more concentrated bands. This is particularly relevant for determining low abundant compounds in limited samples. Nano-LC columns can produce peak capacities of 1000 or more, and very narrow columns can be used to perform proteomics of 1000 cells or less. Also, nano-LC can be coupled with online add-ons such as selective trap columns or enzymatic reactors, for faster and more automated analysis. Nano-LC is today an established tool for research laboratories; but can nano-LC-based systems soon be ready for more routine settings, such as in clinics?


Subject(s)
Chromatography, Liquid/methods , Nanotechnology/methods , Proteomics/methods
7.
PLoS One ; 9(12): e115496, 2014.
Article in English | MEDLINE | ID: mdl-25536063

ABSTRACT

Pancreatic adenocarcinoma (PA) is among the most aggressive human tumors with an overall 5-year survival rate of <5% and available treatments are only minimal effective. WNT/ß-catenin signaling has been identified as one of 12 core signaling pathways that are commonly mutated in PA. To obtain more insight into the role of WNT/ß-catenin signaling in PA we established human PA cell lines that are deficient of the central canonical WNT signaling protein ß-catenin by using zinc-finger nuclease (ZFN) mediated targeted genomic disruption in the ß-catenin gene (CTNNB1). Five individual CTNNB1 gene disrupted clones (BxPC3ΔCTNNB1) were established from a BxPC-3 founder cell line. Despite the complete absence of ß-catenin, all clones displayed normal cell cycle distribution profiles, overall normal morphology and no elevated levels of apoptosis although increased doubling times were observed in three of the five BxPC3ΔCTNNB1 clones. This confirms that WNT/ß-catenin signaling is not mandatory for long term cell growth and survival in BxPC-3 cells. Despite a normal morphology of the ß-catenin deficient cell lines, quantitative proteomic analysis combined with pathway analysis showed a significant down regulation of proteins implied in cell adhesion combined with an up-regulation of plakoglobin. Treatment of BxPC3ΔCTNNB1 cell lines with siRNA for plakoglobin induced morphological changes compatible with a deficiency in the formation of functional cell to cell contacts. In addition, a re-localization of E-cadherin from membranous in untreated to accumulation in cytoplasmatic puncta in plakoglobin siRNA treated BxPC3ΔCTNNB1 cells was observed. In conclusion we describe in ß-catenin deficient BxPC-3 cells a rescue function for plakoglobin on cell to cell contacts and maintaining the localization of E-cadherin at the cellular surface, but not on canonical WNT signaling as measured by TFC/LEF mediated transcription.


Subject(s)
Adenocarcinoma/genetics , Gene Targeting , Genome, Human , Pancreatic Neoplasms/genetics , beta Catenin/metabolism , Adenocarcinoma/pathology , Adherens Junctions/metabolism , Apoptosis/genetics , Base Sequence , Cadherins/metabolism , Cell Adhesion , Cell Cycle/genetics , Cell Line, Tumor , Cell Proliferation , Endocytosis , Endoribonucleases/metabolism , Gene Expression Profiling , Gene Expression Regulation, Neoplastic , Gene Ontology , Humans , Isotope Labeling , Molecular Sequence Data , Mutant Proteins/metabolism , Pancreatic Neoplasms/pathology , Protein Transport , TCF Transcription Factors/metabolism , Transcriptional Activation/genetics , alpha Catenin/metabolism , gamma Catenin/metabolism , Pancreatic Neoplasms
8.
PLoS One ; 9(9): e106881, 2014.
Article in English | MEDLINE | ID: mdl-25222838

ABSTRACT

A novel open tubular nanoproteomic platform featuring accelerated on-line protein digestion and high-resolution nano liquid chromatography mass spectrometry (LC-MS) has been developed. The platform features very narrow open tubular columns, and is hence particularly suited for limited sample amounts. For enzymatic digestion of proteins, samples are passed through a 20 µm inner diameter (ID) trypsin + endoproteinase Lys-C immobilized open tubular enzyme reactor (OTER). Resulting peptides are subsequently trapped on a monolithic pre-column and transferred on-line to a 10 µm ID porous layer open tubular (PLOT) liquid chromatography LC separation column. Wnt/ß-catenein signaling pathway (Wnt-pathway) proteins of potentially diagnostic value were digested+detected in targeted-MS/MS mode in small cell samples and tumor tissues within 120 minutes. For example, a potential biomarker Axin1 was identifiable in just 10 ng of sample (protein extract of ∼1,000 HCT15 colon cancer cells). In comprehensive mode, the current OTER-PLOT set-up could be used to identify approximately 1500 proteins in HCT15 cells using a relatively short digestion+detection cycle (240 minutes), outperforming previously reported on-line digestion/separation systems. The platform is fully automated utilizing common commercial instrumentation and parts, while the reactor and columns are simple to produce and have low carry-over. These initial results point to automated solutions for fast and very sensitive MS based proteomics, especially for samples of limited size.


Subject(s)
Proteomics/methods , Wnt Proteins/chemistry , Biomarkers/chemistry , Cells, Cultured , Chromatography, Liquid , Humans , Mass Spectrometry , Tandem Mass Spectrometry
9.
J Lipid Res ; 55(7): 1531-6, 2014 07.
Article in English | MEDLINE | ID: mdl-24792927

ABSTRACT

Iso-octyl chain-hydroxylated oxysterols were determined in attomoles per 10,000 cells concentrations in 10,000-80,000 cultured pancreatic adenocarcinoma cells, using a sensitive, highly automated nano-LC-ESI-MS-based method. Identified oxysterols included 24S hydroxycholesterol (24S-OHC), 25 hydroxycholesterol (25-OHC), and 27 hydroxycholesterol (27-OHC), while 20S hydroxycholesterol and 22S hydroxycholesterol were not detected. Lower mass limit of quantification was 23 fg (65 amol) for 25-OHC and 27-OHC (100 times lower than our previous method) and 54 fg (135 amol) for 24S-OHC, after derivatization into Girard T hydrazones and online sample cleanup using simplified and robust automatic filtration and filter back flushing solid phase extraction LC/MS/MS. The instrument configuration was easily installed using a commercial nano-LC/MS system. Recoveries in spiked sample were 96, 97, and 77% for 24S-OHC, 25-OHC, and 27-OHC, with within- and between-day repeatabilities of 1-21% and 2-20% relative SD, respectively. The study demonstrates the potential of nano-LC in lipidomics/sterolomics.


Subject(s)
Mass Spectrometry/methods , Oxysterols/analysis , Cell Line, Tumor , Chromatography, Liquid/methods , Humans
10.
J Sep Sci ; 36(17): 2838-47, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23813982

ABSTRACT

The single-run resolving power of current 10 µm id porous-layer open-tubular (PLOT) columns has been optimized. The columns studied had a poly(styrene-co-divinylbenzene) porous layer (~0.75 µm thickness). In contrast to many previous studies that have employed complex plumbing or compromising set-ups, SPE-PLOT-LC-MS was assembled without the use of additional hardware/noncommercial parts, additional valves or sample splitting. A comprehensive study of various flow rates, gradient times, and column length combinations was undertaken. Maximum resolution for <400 bar was achieved using a 40 nL/min flow rate, a 400 min gradient and an 8 m long column. We obtained a 2.3-fold increase in peak capacity compared to previous PLOT studies (950 versus previously obtained 400, when using peak width = 2σ definition). Our system also meets or surpasses peak capacities obtained in recent reports using nano-ultra-performance LC conditions or long silica monolith nanocolumns. Nearly 500 proteins (1958 peptides) could be identified in just one single injection of an extract corresponding to 1000 BxPC3 beta catenin (-/-) cells, and ~1200 and 2500 proteins in extracts of 10,000 and 100,000 cells, respectively, allowing detection of central members and regulators of the Wnt signaling pathway.


Subject(s)
Chromatography, Liquid/instrumentation , Proteomics , Tandem Mass Spectrometry/instrumentation , Animals , Humans , Rats