Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Med ; 13(2)2024 Jan 17.
Article in English | MEDLINE | ID: mdl-38256648

ABSTRACT

BACKGROUND: To examine the applicability of the "taller than wide" (ttw) criterium for risk assessment of thyroid nodules (TNs) in primary/secondary care units and the role of thyroid scintigraphy therein. METHODS: German bicenter study performed in a setting of primary/secondary care. Patient recruitment and analysis in center A was conducted in a prospective manner. In center B, patient data were retrieved from a database that was originally generated by prospective data collection. TNs were assessed by ultrasound and thyroid scans, mostly fine needle biopsy and occasionally surgery and others. In center A, only patients who presented for the first time were included. The inclusion criterion was any TN ≥ 10 mm that had at least the following two sonographic risk features: solidity and a ttw shape. In center B, consecutive patients who had at least ttw and hypofunctioning nodules ≥ 10 mm were retrieved from the above-mentioned database. The risk of malignancy was determined according to a mixed reference standard and compared with literature data. RESULTS: In center A, 223 patients with 259 TNs were included into the study. For further analysis, 200 nodules with a reference standard were available. The overall malignancy rate was 2.5% (upper limit of the 95% CI: 5.1%). After the exclusion of scintigraphically hyperfunctioning nodules, the malignancy rate increased slightly to 2.8% (upper limit of the 95% CI: 5.7%). Malignant nodules exhibited sonographic risk features additional to solidity and ttw shape more often than benign ones. In addition to the exclusion of hyperfunctioning nodules, when considering only nodules without additional US risk features, i.e., exclusively solid and ttw-nodules, the malignancy rate decreased to 0.9% (upper limit 95% CI: 3.7%). In center B, from 58 patients, 58 ttw and hypofunctioning TNs on thyroid scans with a reference standard were available. Malignant nodules from center B were always solid and hypoechoic. The overall malignancy rate of hypofunctioning and ttw nodules was 21%, with the lower limit of the 95% CI (one-sided) being 12%. CONCLUSIONS: In primary/secondary care units, the lowest TIRADS categories for indicating FNB, e.g., applying one out of five sonographic risk features, may not be appropriate owing to the much lower a priori malignancy risk in TNs compared to tertiary/quaternary care units. Even the combination of two sonographic risk features, "solidity" and "ttw", may only be appropriate in a limited fashion. In contrast, the preselection of TNs according to hypofunctioning findings on thyroid scans clearly warranted FNB, even when applying only one sonographic risk criterion ("ttw"). For this reason, thyroid scans in TNs may not only be indicated to rule out hyperfunctioning nodules from FNB but also to rule in hypofunctioning ones.

2.
NMR Biomed ; 33(7): e4298, 2020 07.
Article in English | MEDLINE | ID: mdl-32207190

ABSTRACT

In this study we aimed to assess the effects of continuous formalin fixation on diffusion and relaxation metrics of the ex vivo porcine heart at 7 T. Magnetic resonance imaging was performed on eight piglet hearts using a 7 T whole body system. Hearts were measured fresh within 3 hours of cardiac arrest followed by immersion in 10% neutral buffered formalin. T2* and T2 were assessed using a gradient multi-echo and multi-echo spin echo sequence, respectively. A spin echo and a custom stimulated echo sequence were employed to assess diffusion time-dependent changes in metrics of cardiac diffusion tensor imaging. SNR was determined for b = 0 images. Scans were performed for 5 mm thick apical, midcavity and basal slices (in-plane resolution: 1 mm) and repeated 7, 15, 50, 100 and 200 days postfixation. Eigenvalues of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) decreased significantly (P < 0.05) following fixation. Relative to fresh hearts, FA values 7 and 200 days postfixation were 90% and 80%, while respective relative ADC values at those fixation stages were 78% and 92%. Statistical helix and sheetlet angle distributions as well as respective mean and median values showed no systematic influence of continuous formalin fixation. Similar to changes in the ADC, values for T2 , T2* and SNR dropped initially postfixation. Respective relative values compared with fresh hearts at day 7 were 64%, 79% and 68%, whereas continuous fixation restored T2 , T2* and SNR leading to relative values of 74%, 100%, and 81% at day 200, respectively. Relaxation parameters and diffusion metrics are significantly altered by continuous formalin fixation. The preservation of microstructure metrics following prolonged fixation is a key finding that may enable future studies of ventricular remodeling in cardiac pathologies.


Subject(s)
Diffusion Magnetic Resonance Imaging , Formaldehyde/chemistry , Heart/diagnostic imaging , Tissue Fixation , Animals , Signal-To-Noise Ratio , Spin Labels , Swine
3.
Horm Metab Res ; 49(11): 869-872, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29136676

ABSTRACT

Histological findings often display an association between papillary thyroid carcinomas (PTC) and autoimmune thyroiditis (AIT) and so differ significantly from follicular thyroid carcinomas (FTC). The aim of this interdisciplinary, retrospective study was to evaluate the association of AIT in patients with PTC and FTC and a control group of benign nodular goiters. One hundred thyroidectomies with histologically confirmed differentiated thyroid carcinomas, 67 with PTC and 33 with FTC, were submitted for examination. The two control groups consisted of 60 patients with euthyroid nodular goiter, displaying no signs for malignancy (no surgery) and 100 patients (second control group) with surgery of a benign nodular goiter. Controls were collected to obtain data about the incidence of significantly increased TPOAbs in the first group and of lymphocytic infiltrates (LI) in the second group. High TPOAbs were found in 35% (23/67) of patients with PTC. LI were detected by histology in 48% (32/67) of PTC. Ten patients (10/32) of this group showed the clinical and histological manifestation of a classic AIT with diffuse dense LI as well as diffuse hypoechogeneity in ultrasonography. In 7/32 cases, the histological report described focal dense LI (fAIT) and in 15/32 cases scant scattered LI. AIT and fAIT, together 25% of all PTC (17/67), showed germinal centers and can therefore be characterized as chronic autoimmune thyroiditis. In this group, high TPOAb could be detected in 94% (16/17). Scan scattered LI without germinal centers (15/32) do not represent a fAIT, although TPOAb are high in 47% (7/15). The younger age group (<45 years) showed significantly more often high TPOAbs (p<0.023) in comparison with the age-group older than 60 years. In contrast to PTC, only 4/33 (12%) patients with FTC had high TPOAb levels. We conclude that in contrast to benign euthyroid goiters and to FTC, different degrees of LI are often associated with high TPOAb levels and seem to be significantly increased in PTC, particularly prominent in younger age. There is a high coincidence between LI and high TPOAb levels. In the presence of hypoechoic thyroid nodule, signs of thyroid autoimmunity such as the presence of high TPOAbs, lymphocytic infiltration in cytology, and/or characteristic ultrasonic features, are arguments that might favor the decision for surgery if a cytologically indeterminate thyroid nodule is found and focal autonomy is excluded by szintiscan.


Subject(s)
Carcinoma, Papillary/complications , Thyroid Neoplasms/complications , Thyroiditis, Autoimmune/complications , Adenocarcinoma, Follicular/blood , Adenocarcinoma, Follicular/pathology , Antibodies/blood , Carcinoma, Papillary/blood , Case-Control Studies , Goiter, Nodular/blood , Goiter, Nodular/pathology , Humans , Lymphocytes/pathology , Thyroid Cancer, Papillary , Thyroid Neoplasms/blood , Thyroiditis, Autoimmune/blood
4.
Proc Natl Acad Sci U S A ; 108(5): 1804-9, 2011 Feb 01.
Article in English | MEDLINE | ID: mdl-21245353

ABSTRACT

Bose-Einstein condensation (BEC) is a thermodynamic phase transition of an interacting Bose gas. Its key signatures are remarkable quantum effects like superfluidity and a phonon-like Bogoliubov excitation spectrum, which have been verified for atomic BECs. In the solid state, BEC of exciton-polaritons has been reported. Polaritons are strongly coupled light-matter quasiparticles in semiconductor microcavities and composite bosons. However, they are subject to dephasing and decay and need external pumping to reach a steady state. Accordingly the polariton BEC is a nonequilibrium process of a degenerate polariton gas in self-equilibrium, but out of equilibrium with the baths it is coupled to and therefore deviates from the thermodynamic phase transition seen in atomic BECs. Here we show that key signatures of BEC can even be observed without fulfilling the self-equilibrium condition in a highly photonic quantum degenerate nonequilibrium system.

5.
Opt Express ; 18(19): 20229-41, 2010 Sep 13.
Article in English | MEDLINE | ID: mdl-20940914

ABSTRACT

We present a detailed discussion of a recently demonstrated experimental technique capable of measuring the correlation function of a pulsed light source with picosecond time resolution. The measurement involves a streak camera in single photon counting mode, which is modified such that a signal at a fixed repetition rate, and well defined energy, can be monitored after each pulsed laser excitation. The technique provides further insight into the quantum optical properties of pulsed light emission from semiconductor nanostructures, and the dynamics inside a pulse, on the sub-nanosecond time scale.


Subject(s)
Photometry/instrumentation , Signal Processing, Computer-Assisted/instrumentation , Equipment Design , Equipment Failure Analysis , Photons
SELECTION OF CITATIONS
SEARCH DETAIL
...