Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Contact Dermatitis ; 85(5): 531-542, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34268774

ABSTRACT

BACKGROUND: Metal alloys containing contact sensitizers (nickel, palladium, titanium) are extensively used in medical devices, in particular dentistry and orthopaedic surgery. The skin patch test is used to test for metal allergy. OBJECTIVE: To determine whether metal salts, when applied to freshly excised skin at patch test-relevant concentrations and using a method which mimics skin patch testing, cause in changes in the epidermis and dermis. METHODS: Tissue histology, apoptosis, metabolic activity, and inflammatory cytokine release were determined for two nickel salts, two palladium salts, and four titanium salts. RESULTS: Patch test-relevant concentrations of all metal salts caused localized cytotoxicity. This was observed as epidermis separation at the basement membrane zone, formation of vacuoles, apoptotic nuclei, decreased metabolic activity, and (pro)inflammatory cytokine release. Nickel(II) sulfate hexahydrate, nickel(II) chloride hexahydrate, titanium(IV) bis(ammonium lactato)dihydroxide, and calcium titanate were highly cytotoxic. Palladium(II) chloride, sodium tetrachloropalladate(II), titanium(IV) isopropoxide, and titanium(IV) dioxide showed mild cytotoxicity. CONCLUSION: The patch test in itself may be damaging to the skin of the patient being tested. These results need further verification with biopsies obtained during clinical patch testing. The future challenge is to remain above the elicitation threshold at noncytotoxic metal concentrations.


Subject(s)
Dermatitis, Allergic Contact/etiology , Nickel/adverse effects , Palladium/adverse effects , Patch Tests/methods , Apoptosis/drug effects , Dose-Response Relationship, Drug , Humans , Palladium/administration & dosage
2.
Toxicology ; 393: 62-72, 2018 01 15.
Article in English | MEDLINE | ID: mdl-29079364

ABSTRACT

According to the new EU Medical Devices (MDR) legislation coming into effect in 2017, manufactures will have to comply with higher standards of quality and safety for medical devices in order to meet common safety concerns regarding such products. Metal alloys are extensively used in dentistry and medicine (e.g. orthopedic surgery and cardiology) even though clinical experience suggests that many metals are sensitizers. The aim of this study was to further test the applicability domain of the in vitro reconstructed human epidermis (RhE) IL-18 assay developed to identify contact allergens and in doing so: i) determine whether different metal salts, representing leachables from metal alloys used in medical devices, could be correctly labelled and classified; and ii) assess the ability of different salts for the same metal to penetrate the skin stratum corneum. Twenty eight chemicals including 15 metal salts were topically exposed to RhE. Nickel, chrome, gold, palladium were each tested in two different salt forms, and titanium in 4 different salt forms. Metal salts were labelled (YES/NO) as sensitizer if a threshold of more than 5 fold IL18 release was reached. The in vitro estimation of expected sensitization induction level (potency) was assessed by interpolating in vitro EC50 and IL-18 SI2 with LLNA EC3 and human NOEL values from standard reference curves generated using DNCB (extreme) and benzocaine (weak). Metal salts, in contrast to other chemical sensitizers and with the exception of potassium dichromate (VI) and cobalt (II) chloride, were not identified as contact allergens since they only induced a small or no increase in IL-18 production. This finding was not related to a lack of stratum corneum skin penetration since EC50 values (decrease in metabolic activity; MTT assay) were obtained after topical RhE exposure to 8 of the 15 metal salts. For nickel, gold and palladium salts, differences in EC50 values between two salts for the same metal could not be attributed to differences in molarity or valency. For chrome salts the difference in EC50 values may be explained by different valencies (VI vs. III), but not by molarity. In general, metal salts were classified as weaker sensitizers than was indicated from in vivo LLNA EC3 and NOEL data. Our in vitro results show that metals are problematic chemicals to test, in line with the limited number of standardized human and animal studies, which are not currently considered adequate to predict systemic hypersensitivity or autoimmunity, and despite clinical experience, which clearly shows that many metals are indeed a risk to human health.


Subject(s)
Allergens/toxicity , Epidermis/drug effects , Haptens/toxicity , Interleukin-18/immunology , Metals/toxicity , Animal Testing Alternatives , Epidermis/immunology , Humans , Infant, Newborn , Local Lymph Node Assay , Male , No-Observed-Adverse-Effect Level , Toxicity Tests/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...