Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
J Cardiovasc Dev Dis ; 11(5)2024 May 17.
Article in English | MEDLINE | ID: mdl-38786975

ABSTRACT

Mitral stenosis (MS) poses significant challenges in diagnosis and management due to its varied etiologies, such as rheumatic mitral stenosis (RMS) and degenerative mitral stenosis (DMS). While rheumatic fever-induced RMS has declined in prevalence, DMS is rising with aging populations and comorbidities. Starting from a complex clinical case of DMS, the aim of this paper is to review the literature on mitral stenosis by analyzing the available tools and the differences in terms of diagnosis and treatment for rheumatic and degenerative stenosis. Emerging transcatheter techniques, such as transcatheter mitral valve replacement (TMVR) and lithotripsy-facilitated percutaneous mitral commissurotomy (PMC), represent promising alternatives for DMS patients deemed unfit for surgery. In particular, intravascular lithotripsy (IVL) has shown potential in facilitating percutaneous interventions by fracturing calcific deposits and enabling subsequent interventions. However, larger prospective studies are warranted to validate these findings and establish IVL's role in DMS management. To further enhance this technique, research could focus on investigating the long-term outcomes and durability of mitral lithotripsy, as well as exploring its potential in combination with PMC or TMVR.

2.
G Ital Cardiol (Rome) ; 25(5): 295-299, 2024 May.
Article in Italian | MEDLINE | ID: mdl-38639118

ABSTRACT

Patent foramen ovale (PFO) is a remnant of normal fetal anatomy which may persist into adulthood, mostly asymptomatic. In some adults, PFO may result in a potential for shunting venous thromboembolism to the arterial circulation; less frequently it can cause interatrial, right-to-left shunting of deoxygenated blood. The pathogenesis of several medical conditions is related to the presence of PFO. Some randomized clinical trials have shown evidence of benefit for device closure as compared with medical therapy in patients with cryptogenic stroke. The literature reported several cases of carbon dioxide embolism during general laparoscopic surgery and sometimes stroke after laparoscopic or neurosurgery but there are neither prospective studies addressing these issues, nor randomized clinical trials assessing the effectiveness of pharmacotherapy or interventional procedures at decreasing risk. The European position paper suggests routine monitoring in non-cardiac surgery of patients with a PFO and no actual indications for closure. This article aims to further stratify the risk of periprocedural stroke and paradoxical embolism in this category of patients.


Subject(s)
Embolism, Paradoxical , Foramen Ovale, Patent , Stroke , Adult , Humans , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/surgery , Prospective Studies , Stroke/prevention & control , Stroke/complications , Secondary Prevention/methods , Embolism, Paradoxical/etiology , Embolism, Paradoxical/prevention & control , Treatment Outcome
3.
Can J Cardiol ; 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38492735

ABSTRACT

BACKGROUND: In patients with atrial fibrillation (AF) on vitamin K antagonist (VKA) therapy and therapeutic international normalized ratio (INR) range, the incidence of cardiac thromboembolism is not negligible, and the subgroup of patients who have a mechanical prosthetic mitral valve (PMV) has the highest risk. We aimed to assess the long-term effects of left atrial appendage closure (LAAC) in AF patients with a mechanical PMV who experienced a failure of VKA therapy. METHODS: In this retrospective, multicentre study, patients underwent LAAC because of thrombotic events including transient ischemic attack and/or stroke, systemic embolism, and evidence of left atrial appendage thrombosis and/or sludge, despite VKA therapy, were enrolled. Patients with a mechanical PMV were included and compared with those affected by nonvalvular AF. The primary endpoint was the composite of all-cause death, major cardiovascular events, and major bleedings at follow-up. The feasibility and safety of LAAC also were assessed. RESULTS: A total of 55 patients (42% female; mean age, 70 ± 9 years), including 12 with a mechanical PMV, were enrolled. The most-frequent indication to LAAC (71%) was LAA thrombosis or sludge. Procedural success was achieved in 96% of overall cases, and in 100% of patients with a PMV. In 35 patients, a cerebral protection device was used. During a median follow-up of 6.1 ± 4.3 years, 4 patients with a PMV, and 20 patients without a PMV, reported adverse events (hazard ratio 0.73 [95% confidence interval 0.25-2.16, P = 0.564]). CONCLUSIONS: LAAC seems to be a valuable alternative in patients with AF who have a mechanical PMV, with failure of VKA therapy. This off-label, real-world clinical practice indication deserves validation in further studies.

4.
EuroIntervention ; 20(5): e289-e300, 2024 Mar 04.
Article in English | MEDLINE | ID: mdl-37982178

ABSTRACT

BACKGROUND: Microvascular resistance reserve (MRR) is a validated measure of coronary microvascular function independent of epicardial resistances. AIMS: We sought to assess whether MRR is associated with adverse cardiac remodelling, a low-flow phenotype and extravalvular cardiac damage (EVCD) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS: Invasive thermodilution-based assessment of the coronary microvascular function of the left anterior descending artery was performed in a prospective, multicentre cohort of patients undergoing TAVI. Coronary microvascular dysfunction (CMD) was defined as the lowest MRR tertile of the study cohort. Haemodynamic measurements were performed at baseline and then repeated immediately after TAVI. EVCD and markers of a low-flow phenotype were assessed with echocardiography. RESULTS: A total of 134 patients were included in this study. Patients with low MRR were more frequently females, had a lower estimated glomerular filtration rate and a higher rate of atrial fibrillation. MRR was significantly lower in patients with advanced EVCD (median 1.80 [1.26-3.30] vs 2.50 [1.87-3.41]; p=0.038) and in low-flow, low-gradient AS (LF LG-AS) (median 1.85 [1.20-3.04] vs 2.50 [1.87-3.40]; p=0.008). Overall, coronary microvascular function tended to improve after TAVI and, in particular, MRR increased significantly after TAVI in the subgroup with low MRR at baseline. However, MRR was significantly impaired in 38 (28.4%) patients immediately after TAVI. Advanced EVCD (adjusted odds ratio 3.08 [1.22-7.76]; p=0.017) and a low-flow phenotype (adjusted odds ratio 3.36 [1.08-10.47]; p=0.036) were significant predictors of CMD. CONCLUSIONS: In this observational, hypothesis-generating study, CMD was associated with extravalvular cardiac damage and a low-flow phenotype in patients with severe AS undergoing TAVI.


Subject(s)
Aortic Valve Stenosis , Myocardial Ischemia , Transcatheter Aortic Valve Replacement , Female , Humans , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Prospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
5.
Cardiovasc Revasc Med ; 62: 85-94, 2024 May.
Article in English | MEDLINE | ID: mdl-38160130

ABSTRACT

Valve-in-valve transcatheter aortic valve implantation (ViV TAVI) is rapidly arising as a safe and effective alternative to redo-surgery in the treatment of bioprostheses deterioration. While scientific community is currently focusing its attention on the most common limitations related to this procedure, such as the risk of coronary obstruction and patient-prosthesis mismatch, data regarding the first step of a ViV TAVI, the crossing of a degenerated bioprosthesis, are still lacking. The aim of this review is to analyze the available information about bioprosthesis crossing, to show the inherent challenges encountered by interventional cardiologists during valve crossing and to describe the current strategies to perform a correct crossing.


Subject(s)
Aortic Valve , Bioprosthesis , Heart Valve Prosthesis , Prosthesis Design , Prosthesis Failure , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Treatment Outcome , Risk Factors , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects
6.
JACC Case Rep ; 22: 101978, 2023 Sep 20.
Article in English | MEDLINE | ID: mdl-37790775

ABSTRACT

Ischemia with no obstructive coronary artery disease (INOCA) is not an uncommon diagnosis in patients presenting with chest pain who undergo clinically indicated coronary angiography. However, the symptoms reported by patients with INOCA may be heterogeneous, leading to misdiagnosis and undertreatment. Herein we report 3 clinical cases of INOCA misdiagnosis and describe how the cases were reinvestigated following the appropriate diagnostic pathway. (Level of Difficulty: Advanced.).

8.
Catheter Cardiovasc Interv ; 102(3): 486-488, 2023 09.
Article in English | MEDLINE | ID: mdl-37454283

ABSTRACT

Intracoronary calcium embolization during percutaneous procedure is a very rare and unpredictable event, that  can lead to serious complications and even expert operators could face some technical issues to solve it. This case report presents a technique called "block and crack" used to manage iatrogenic intracoronary calcium embolization of left anterior descending coronary artery. The technique involves implanting a drug eluting stent (DES) to block the embolus against the vessel wall, followed by the use of lithotripsy balloon inflated inside the DES to crack the calcium and achieve a better stent expansion. This technique allowed to avoid further distal calcium embolization as well as to minimize residual stenosis degree after stent implantation.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Lithotripsy , Percutaneous Coronary Intervention , Humans , Coronary Artery Disease/therapy , Calcium , Coronary Angiography/methods , Treatment Outcome , Percutaneous Coronary Intervention/adverse effects , Lithotripsy/adverse effects , Iatrogenic Disease , Ultrasonography, Interventional
14.
Cardiovasc Revasc Med ; 43: 1-6, 2022 10.
Article in English | MEDLINE | ID: mdl-35690553

ABSTRACT

BACKGROUND: Transcatheter aortic valve implant (TAVI) is gaining momentum in the treatment of severe, symptomatic aortic valve stenosis, and its indication is expanding to lower surgical risk individuals, who are generally younger and have a long life expectancy. Therefore, transcatheter bioprostheses durability appears of critical importance. Aim of the present study is to evaluate mid-term outcomes of TAVI in a high-volume single center cohort. METHODS: We analyzed all consecutive patients (n = 408) who underwent transfemoral TAVI at a single, high-volume center, between 2007 and 2014. Study objectives were all-cause death and bioprosthetic valve failure (BVF) at long term follow-up. Structural valve deterioration (SVD), BVF and valve-related death were defined according to current international standards. Follow-up was performed by in person visit and transthoracic echocardiography, which was obtained only in a minority of patients, or phone call as per patient preference. RESULTS: At a median follow-up of 1821 days, overall mortality was 64.5%, with cardiovascular disease accounting for roughly half of total deaths. Valve-related deaths occurred in 10 patients. Seventeen patients were diagnosed with BVF, and 15 required repeat intervention. Moderate and severe SVD were observed in 10 and 7 patients, respectively. In the subgroup of patients with echocardiographic mid-term follow-up (n = 76), no significant increase of transprosthetic gradients nor increase of significant regurgitation was detected. CONCLUSION: In the present unselected, all-comers cohort, TAVI bioprostheses appeared to have excellent durability at long-term follow-up.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Prosthesis Failure , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
19.
Int J Cardiol Heart Vasc ; 34: 100817, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34169142

ABSTRACT

INTRODUCTION: Based on recent data, the indication for transcatheter aortic valve implantation (TAVI) is expanding to individuals at lower surgical risk, who are generally younger than subjects historically treated for severe aortic stenosis. Indeed, younger patients have traditionally been under-represented in current TAVI literature. The aim of the present study is to report about clinical features, procedural outcomes and mid-term outcomes of patients younger than 70 who underwent TAVI in a single high-volume center. MATERIALS AND METHODS: Consecutive patients younger than 70 years of age who underwent TAVI for severe, symptomatic aortic stenosis between 2007 and 2019 at a single, tertiary referral center have been included in this retrospective study. Procedural and mid-term outcomes were analyzed, comparing 1st generation with 2nd generation devices. RESULTS: Between 2007 and 2019, 1740 TAVI procedures were performed in our center. Among these, one hundred twenty-nine (7.4%) patients were younger than 70 years at the time of the intervention and were included in the present analysis. Fifty-eight patients (45%) were implanted with a 1st generation prosthesis while seventy-one patients (55%) were implanted with a 2nd generation device. Reasons which lead to a transcatheter approach in this population were: previous CABG (27.9%); porcelain aorta (24%); severe left ventricular systolic dysfunction (21.7%); prior chest radiation (19.4%); severe lung disease (8.5%); hemodynamic instability (7.0%); advanced liver disease (4.6%) and active cancer (3.9%). Overall device success rate was 89%, with no differences among 1st and 2nd generation devices. Threeyears all-cause mortality was 34%, with no difference among the two groups. Low incidence of aortic-valve re-intervention was observed at mid-term follow-up (late valve re-intervention = 2.3%). CONCLUSIONS: TAVI in young patient with appropriate indication for intervention is a safe procedure, associated with low rate of in hospital mortality and low rate of severe complications both with 1st and with 2nd generation devices. When considering long term durability, more data are needed; in our case series long-term follow up shows a good survival and also an extremely low rate of valve re-intervention.

20.
J Invasive Cardiol ; 33(2): E141-E142, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33531446

ABSTRACT

To the best of our knowledge, this is the first description of intravascular-ultrasound guided coronary lithotripsy on saphenous vein graft because of severely calcific in-stent restenosis, showing good result without procedural complications.


Subject(s)
Coronary Restenosis , Lithotripsy , Coronary Angiography , Coronary Restenosis/diagnosis , Coronary Restenosis/etiology , Coronary Restenosis/surgery , Humans , Saphenous Vein/diagnostic imaging , Saphenous Vein/surgery , Stents/adverse effects , Treatment Outcome , Ultrasonography, Interventional
SELECTION OF CITATIONS
SEARCH DETAIL
...