Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Orthopedics ; 24(8): 747-51, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11518403

ABSTRACT

Outcome of the acetabular component in 90 consecutive primary noncemented total hip arthroplasties (THAs) was prospectively studied. The acetabular cup consisted of a hemispherical titanium alloy shell with a titanium fiber-mesh porous coating and a modular polyethylene liner (Harris-Galante Porous-1, Zimmer, Warsaw, Ind). The cup was implanted using line-to-line reaming with adjunctive dome screw fixation. The femoral component consisted of a titanium alloy stem with titanium fiber-mesh porous coating and a 28-mm cobalt-chrome modular head. Mean patient age was 53 years (range: 27-75 years); male:female ratio was 48:42; and mean follow-up was 6 years (range: 4.5-8 years). One acetabular component was revised for aseptic loosening. Of 81 unrevised hips available for follow-up, mean Harris hip score was 57 preoperatively and 96 at final follow-up (72% excellent, 15% good, 1 3% fair, and none poor). Of 61 unrevised hips with adequate radiographic follow-up, radiographic failure (complete periprosthetic radiolucency) was evident in 3 (4.9%) and periacetabular osteolysis in none. Radiographic failure did not correlate with poor clinical outcome. Linear polyethylene wear rate (mean: 0.13 mm/year) did not correlate with age, gender, weight, outcome, or cup abduction angle, but did correlate with the presence of femoral periprosthetic osteolysis (0.18 mm/year with femoral osteolysis versus 0.11 mm/year without; P= .01). This series of porous-coated hemispherical cups demonstrated excellent intermediate-term clinical and radiographic outcome, comparable with similarly favorable results reported by the prosthesis designers. A potentially adverse effect of polyethylene wear on the longevity of a THA was supported by a positive correlation between polyethylene wear rate and femoral osteolysis.


Subject(s)
Hip Prosthesis , Adult , Aged , Coated Materials, Biocompatible , Female , Follow-Up Studies , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Radiography , Surface Properties , Time Factors
2.
Orthopedics ; 24(12): 1139-43, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11770090

ABSTRACT

This study compared the efficacy and cost of radiation therapy with indomethacin in the prophylaxis of heterotopic ossification following total hip replacement. Twenty-two patients received a radiation dose of 10 Gy in five fractions, 28 patients 8 Gy in one fraction, and 27 patients 25 mg oral indomethacin three times a day for either 7 or 21 days. Patients at higher risk for heterotopic ossification were more likely to receive radiation therapy than indomethacin. At a mean follow-up of 2 years, there were no differences in failure rates between the high-risk patients treated with radiation and the low-risk patients treated with indomethacin. Currently, the patient-billed cost of radiation is $1400 whereas the cost for indomethacin is approximately $100. Indomethacin appears to be as effective as radiation therapy in patients at low to moderate risk for heterotopic ossification and offers significant cost savings.


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal/therapeutic use , Arthroplasty, Replacement, Hip/adverse effects , Indomethacin/therapeutic use , Ossification, Heterotopic/prevention & control , Radiotherapy , Adult , Aged , Aged, 80 and over , Female , Health Care Costs , Humans , Male , Middle Aged , Ossification, Heterotopic/etiology , Retrospective Studies , Risk Factors , Treatment Failure
SELECTION OF CITATIONS
SEARCH DETAIL
...