Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Contact Dermatitis ; 74(1): 18-21, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26489693

ABSTRACT

BACKGROUND: Anti-vascular endothelial growth factor (VEGF) medication, injected intravitreally, is currently the standard of care in patients with different retinal pathologies. Since its introduction in 2006, an increasing number of patients have undergone this procedure in Ghent University Hospital. Strikingly, more patients were diagnosed with contact dermatitis caused by ophthalmic products used during intravitreal injection procedure. OBJECTIVES: To identify which of the substances used during intravitreal injection is most likely to cause contact dermatitis. PATIENTS/MATERIALS/METHODS: Sixteen patients who developed a burning and stinging sensation and swelling of the eyelids after intravitreal injection were tested. All patients were patch tested with the Belgian baseline series, as well as a cosmetic, a pharmaceutical and an ophthalmic series, including the different eye drops used during the intravitreal injection procedure. RESULTS: Fourteen of 16 patients reacted to at least one of the substances used during the injection procedure. Nine patients reacted to phenylephrine (56%), 5 to iso-Betadine(®) ophthalmic solution (31%), and 3 patients to sodium metabisulfite (16%). CONCLUSIONS: The most common causal allergen was phenylephrine, being positive in 56% of patients. Patients most likely become sensitized because of the high frequency of usage of phenylephrine during repeated intravitreal injections and follow-up consultations.


Subject(s)
Anti-Infective Agents, Local/adverse effects , Dermatitis, Allergic Contact/etiology , Phenylephrine/adverse effects , Povidone-Iodine/adverse effects , Sulfites/adverse effects , Vascular Endothelial Growth Factor A/antagonists & inhibitors , Aged , Aged, 80 and over , Anti-Infective Agents, Local/administration & dosage , Female , Humans , Intravitreal Injections , Male , Middle Aged , Ophthalmic Solutions , Patch Tests , Phenylephrine/administration & dosage , Povidone-Iodine/administration & dosage , Sulfites/administration & dosage
2.
Anal Bioanal Chem ; 396(7): 2461-8, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20140665

ABSTRACT

There is a need for a reliable rapid on-site oral fluid test that can be used in police controls to detect impaired drivers. We evaluated the Varian Oralab6 and collected two oral fluid samples from 250 subjects, one with the Varian Oralab6 and one with the StatSure Saliva Sampler. The Oralab6 can detect six drug types: amphetamines, methamphetamine, cocaine, opiates, delta9-tetrahydrocannabinol (THC), and phencyclidine (PCP). On-site results were obtained within 10 to 15 min. The sample collected with StatSure was analyzed using liquid chromatography-tandem mass spectrometry after liquid-liquid extraction and these results were used as a reference to determine prevalence, sensitivity, and specificity. Two cut-off values were used in the evaluation. The Varian cut-off values were: amphetamine 50 ng/mL, cocaine 20 ng/mL, opiates 40 ng/mL, and THC 50 ng/mL. The DRUID cut-offs were: amphetamine 25 ng/mL, cocaine 20 ng/mL, opiates 20 ng/mL, and THC 1 ng/mL. Applying the first cut-offs, prevalence, sensitivity, and specificity were: amphetamine 10%, 76%, 100%; cocaine 23%, 34%, 100%; opiates 38%, 83%, 94%; and THC 18%, 41%, 99%. The DRUID cut-off values gave the following results: amphetamine 14%, 56%, 100%; cocaine 28%, 34%, 100%; opiates 49%, 68%, 98%, and THC 45%, 16%, 99%. The specificity of the Oralab6 is generally good. For both cut-offs, sensitivity was low for cocaine and THC. Therefore, the Varian Oralab6 test is not sensitive enough to be applied during roadside police controls.


Subject(s)
Automobile Driving , Drug Evaluation, Preclinical/instrumentation , Forensic Medicine/instrumentation , Illicit Drugs/analysis , Saliva/chemistry , Equipment Design , Equipment Failure Analysis , Europe , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...