1.
Article in English | MEDLINE | ID: mdl-38991839

ABSTRACT

OBJECTIVES: The potential risk of autograft dilatation and homograft stenosis after the Ross procedure mandates lifelong follow-up. This retrospective cohort study aimed to determine long-term outcome of the Ross procedure, investigating autograft and homograft failure patterns leading to reintervention. METHODS: All adults who underwent the Ross procedure between 1991-2018 at the University Hospitals Leuven were included, with follow-up data collected retrospectively. Autograft implantation was performed using the full root replacement technique. The primary end-point was long-term survival. Secondary end-points were survival free from any reintervention, autograft or homograft reintervention-free survival, and evolution of autograft diameter, homograft gradient and aortic regurgitation grade over time. RESULTS: A total of 173 adult patients (66% male) with a median age of 32 years (range 18-58 years) were included. External support at both the annulus and sinotubular junction was used in 38.7% (67/173). Median follow-up duration was 11.1 years (IQR, 6.4-15.9; 2065 patient-years) with 95% follow-up completeness. There was one (0.6%) perioperative death. Kaplan-Meier estimate for 15-year survival was 91.1% and Ross-related reinterventionfree survival was 75.7% (autograft: 83.5%, homograft: 85%). Regression analyses demonstrated progressive neoaortic root dilatation (0.56 mm/year) and increase in homograft gradient (0.72 mmHg/year). CONCLUSIONS: The Ross procedure has the potential to offer excellent long-term survival and reintervention-free survival. These long-term data further confirm that the Ross procedure is a suitable option in young adults with aortic valve disease which should be considered on an individual basis.

3.
J Biomech ; 171: 112180, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38906711

ABSTRACT

In the Ross procedure, a patient's pulmonary valve is transplanted in the aortic position. Despite advantages of this surgery, reoperation is still needed in many cases due to excessive dilatation of the pulmonary autograft. To further understand the failure mechanisms, we propose a multiscale model predicting adaptive processes in the autograft at the cell and tissue scale. The cell-scale model consists of a network model, that includes important signaling pathways and relations between relevant transcription factors and their target genes. The resulting gene activity leads to changes in the mechanical properties of the tissue, modeled as a constrained mixture of collagen, elastin and smooth muscle. The multiscale model is calibrated with findings from experiments in which seven sheep underwent the Ross procedure. The model is then validated against a different set of sheep experiments, for which a qualitative agreement between model and experiment is found. Model outcomes at the cell scale, including the activity of genes and transcription factors, also match experimentally obtained transcriptomics data.


Subject(s)
Pulmonary Valve , Pulmonary Valve/surgery , Pulmonary Valve/transplantation , Animals , Sheep , Autografts , Signal Transduction , Models, Cardiovascular , Computer Simulation , Humans , Aortic Valve/surgery , Aortic Valve/pathology
4.
J Clin Med ; 13(9)2024 May 02.
Article in English | MEDLINE | ID: mdl-38731198

ABSTRACT

Background: Mitral valve prolapse (MVP) and mitral annular disjunction (MAD) are common valvular abnormalities that have been associated with ventricular arrhythmias (VA). Cardiac magnetic resonance imaging (CMR) has a key role in risk stratification of VA, including assessment of late gadolinium enhancement (LGE). Methods: Single-center retrospective analysis of patients with MVP or MAD who had >1 CMR and >1 24 h Holter registration available. Data are presented in detail, including evolution of VA and presence of LGE over time. Results: A total of twelve patients had repeated CMR and Holter registrations available, of which in four (33%) patients, it was conducted before and after minimal invasive mitral valve repair (MVR). After a median of 4.7 years, four out of eight (50%) patients without surgical intervention had new areas of LGE. New LGE was observed in the papillary muscles and the mid to basal inferolateral wall. In four patients, presenting with syncope or high-risk non-sustained ventricular tachycardia (VT), programmed ventricular stimulation was performed and in two (50%), sustained monomorphic VT was easily inducible. In two patients who underwent MVR, new LGE was observed in the basal inferolateral wall of which one presented with an increased burden of VA. Conclusions: In patients with MVP and MAD, repeat CMR may show new LGE in a small subset of patients, even shortly after MVR. A subgroup of patients who presented with an increase in VA burden showed new LGE upon repeat CMR. VA in patients with MVP and MAD are part of a heterogeneous spectrum that requires further investigation to establish risk stratification strategies.

5.
Article in English | MEDLINE | ID: mdl-38688452

ABSTRACT

OBJECTIVES: Randomized controlled trials comparing transcatheter aortic valve implantation with surgical aortic valve replacement demonstrate conflicting evidence, particularly in low-risk patients. We aim to reevaluate the evidence using trial sequential analysis, balancing type I and II errors, and compare with conventional meta-analysis. METHODS: Databases were searched for randomized controlled trials, which were divided into higher-risk and lower-risk randomized controlled trials according to a pragmatic risk classification. Primary outcomes were death and a composite end point of death or disabling stroke assessed at 1 year and maximum follow-up. Conventional meta-analysis and trial sequential analysis were performed, and the required information size was calculated considering a type I error of 5% and a power of 90%. RESULTS: Eight randomized controlled trials (n = 5274 higher-risk and 3661 lower-risk patients) were included. Higher-risk trials showed no significant reduction in death at 1 year with transcatheter aortic valve implantation (relative risk, 0.93, 95% CI, 0.81-1.08, P = .345). Lower-risk trials suggested lower death risk on conventional meta-analysis (relative risk, 0.67, 95% CI, 0.47-0.96, P = .031), but trial sequential analysis indicated potential spurious evidence (P = .116), necessitating more data for conclusive benefit (required information size = 5944 [59.8%]). For death or disabling stroke at 1 year, higher-risk trials lacked evidence (relative risk, 0.90, 95% CI, 0.79-1.02, P = .108). In lower-risk trials, transcatheter aortic valve implantation indicated lower risk in conventional meta-analysis (relative risk, 0.68, 95% CI, 0.50-0.93, P = .014), but trial sequential analysis suggested potential spurious evidence (P = .053), necessitating more data for conclusive benefit (required information size = 5122 [69.4%]). Follow-up results provided inconclusive evidence for both primary outcomes across risk categories. CONCLUSIONS: Conventional meta-analysis methods may have prematurely declared an early reduction of negative outcomes after transcatheter aortic valve implantation when compared with surgical aortic valve replacement.

6.
Article in English | MEDLINE | ID: mdl-38630154

ABSTRACT

Aim of this study was to compare redo MV surgery patients undergoing right mini-thoracotomy and EAC with redo MV patients undergoing surgery through other approaches. Redo MV patients from 7 European centers were analyzed. Primary endpoint was 30-day mortality; secondary endpoints were stroke, re-exploration, low cardiac output syndrome (LCOS), respiratory failure, and intensive care unit (ICU) and in-hospital length-of-stay. Forty-nine patients underwent right mini-thoracotomy and EAC (22.7%), and 167 (77.3%) underwent surgery through other approaches (112 sternotomy, 40 unclamped mini-thoracotomies, and 15 mini-thoracotomies with trans-thoracic clamp). Thirty-day mortality, stroke, re-exploration for bleeding, and weaning failure were comparable. The EAC group showed significant lower rate of LCOS (p = 0.03) and shorter ICU (p = 0.04) and in-hospital length of stay (p = 0.002). The EAC allows the surgeon to reach the aorta, to clamp it, and to deliver the cardioplegia with a "no-touch" technique, with significant improvement in outcomes.

7.
J Appl Physiol (1985) ; 136(3): 606-617, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38328825

ABSTRACT

We aimed to develop a large animal model of subcoronary aortic stenosis (AS) to study intracoronary and microcirculatory hemodynamics. A total of three surgical techniques inducing AS were evaluated in 12 sheep. Suturing the leaflets together around a dilator (n = 2) did not result in severe AS. Suturing of a pericardial patch with a variable opening just below the aortic valve (n = 5) created an AS which was poorly tolerated if the aortic valve area (AVA) was too small (0.38-1.02 cm2), but was feasible with an AVA of 1.2 cm2. However, standardization of aortic regurgitation (AR) with this technique is difficult. Therefore, we opted for implantation of an undersized AV-bioprosthesis with narrowing sutures on the leaflets (n = 5). Overall, five sheep survived the immediate postoperative period of which three had severe AS (one patch and two bioprostheses). The surviving sheep with severe AS developed left ventricular hypertrophy and signs of increased filling-pressures. Intracoronary assessment of physiological indices in these AS sheep pointed toward the development of functional microvascular dysfunction, with a significant increase in coronary resting flow and hyperemic coronary resistance, resulting in a significantly higher index of microvascular resistance (IMR) and lower myocardial resistance reserve (MRR). Microscopic analysis showed myocardial hypertrophy and signs of fibrosis without evidence of capillary rarefaction. In a large animal model of AS, microvascular changes are characterized by increased resting coronary flow and hyperemic coronary resistance resulting in increased IMR and decreased MRR. These physiological changes can influence the interpretation of regularly used coronary indices.NEW & NOTEWORTHY In an animal model of aortic valve stenosis (AS), coronary physiological changes are characterized by increased resting coronary flow and hyperemic coronary resistance. These changes can impact coronary indices frequently used to assess concomitant coronary artery disease (CAD). At this point, the best way to assess and treat CAD in AS remains unclear. Our data suggest that fractional flow reserve may underestimate CAD, and nonhyperemic pressure ratios may overestimate CAD severity before aortic valve replacement.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Animals , Sheep , Microcirculation , Coronary Circulation , Hemodynamics , Aortic Valve Stenosis/surgery , Coronary Stenosis/surgery , Coronary Stenosis/diagnosis
8.
Catheter Cardiovasc Interv ; 103(2): 382-388, 2024 02.
Article in English | MEDLINE | ID: mdl-38078877

ABSTRACT

BACKGROUND: Evidence-based recommendations for antithrombotic treatment in patients who have an indication for oral anticoagulation (OAC) after transcatheter edge-to-edge mitral valve repair (TEER) are lacking. AIMS: To compare bleeding and thrombotic risk for different antithrombotic regimens post-TEER with MitraClip in an unselected population with the need for OACs. METHODS: Bleeding and thrombotic complications (stroke and myocardial infarction) up to 3 months after TEER with mitraclip were evaluated in 322 consecutive pts with an indication for OACs. These endpoints were defined by the Mitral Valve Academic Research Consortium criteria and were compared between two antithrombotic regimens: single antithrombotic therapy with OAC (single ATT) and double/triple ATT with a combination of OAC and aspirin and/or clopidogrel (combined ATT). RESULTS: Collectively, 108 (34%) patients received single ATT, 203 (63%) received double ATT and 11 (3%) received triple ATT. Bleeding events occurred in 67 patients (20.9%), with access site related events being the most frequent cause (37%). Bleeding complications were observed more frequently in the combined ATT group than in the single ATT group: 24% versus 14% [p = 0.03, adjusted RR: 0.55 (0.3-0.98)]. Within the combined group, the bleeding risk was 23% in the double ATT and 45% in the triple ATT group. Thrombotic complications occurred in only three patients (0.9%), and all belonged to the combined ATT group. CONCLUSIONS: In patients with an indication for OACs, withholding of antiplatelet therapy post-TEER with Mitraclip was associated with a 45% reduction in bleeding and without a signal of increased thrombotic risk.


Subject(s)
Platelet Aggregation Inhibitors , Thrombosis , Humans , Platelet Aggregation Inhibitors/adverse effects , Anticoagulants/adverse effects , Fibrinolytic Agents/adverse effects , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Hemorrhage/chemically induced , Thrombosis/etiology , Thrombosis/prevention & control , Registries
9.
Acta Cardiol ; 79(1): 30-40, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37882608

ABSTRACT

AIMS: Sutureless aortic valve replacement (SU-AVR) and transcatheter aortic valve implantation (TAVI) are both viable therapeutic interventions for aortic stenosis in elderly patients. Meta-analyses show similar all-cause mortality for both techniques albeit with a different pattern of adverse effects. This study means to compare costs and, to a lesser extent, clinical outcomes of both techniques. METHODS: A retrospective single-centre analysis was performed for patients receiving SU-AVR or TAVI from 2008 to 2019. Perioperative clinical data were collected from patient files. Costs were assessed by a cost allocation tool. In an attempt to avoid confounding, propensity score matching was carried out. RESULTS: A total of 368 patients underwent either TAVI (n = 100) or SU-AVR (n = 268). After matching, there were 61 patients per treatment group. Length of stay was significantly longer in the SU-AVR group. Excluding device costs, total expenses for SU-AVR (median: €11,630) were significantly higher than TAVI (median: €9240). For both groups, these costs were mostly incurred on intensive care units, followed by nursing units. Non-medical staff was the largest contributor to expenses. Including device costs, SU-AVR (median: €14,683) was shown to be cost-saving compared to TAVI (median: €24,057). CONCLUSIONS: To conclude, we found SU-AVR to be cost-saving compared to TAVI, largely due to higher device costs associated with the latter. Excluding device costs, TAVI was associated with lower expenses and shorter length of stay. Non-medical staff was the largest source of costs, suggesting length of stay to be a major financial determinant.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aged , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Treatment Outcome , Aortic Valve Stenosis/surgery , Costs and Cost Analysis , Risk Factors
11.
Eur J Cardiothorac Surg ; 64(5)2023 11 01.
Article in English | MEDLINE | ID: mdl-37756688

ABSTRACT

OBJECTIVES: There are several treatment options for non-elderly adults (18-60 years) in need of aortic valve replacement (AVR): a mechanical or biological substitute, a homograft, the Ross procedure or nowadays even transcatheter aortic valve replacement. This study evaluated the current opinions and practices of cardiac surgeons and cardiologists concerning AVR strategies in this patient group. METHODS: A 43-item online survey was sent out to several scientific organizations, individual cardiac surgeons, cardiologists and residents/fellows worldwide. RESULTS: Two hundred twenty-two physicians from 33 different countries answered the survey. The UK (24%), Belgium (23%) and North America (22%) are best represented. A mechanical valve is the most frequently used substitute in non-elderly. With increasing patient age, the popularity of a biological valve increases. Transcatheter aortic valve replacement and the Ross procedure are each used in <10% of this cohort. Only 12% of the cardiac surgeons has experience with the Ross surgery. In 23%, the patient seems not to be involved in the decision on the type of valve substitute. CONCLUSIONS: The preferred surgical treatment for non-elderly patients in need of AVR differs widely. To enable a shared decision-making process including patient preferences, there is more need for collaboration between cardiac departments, as well as education and scientific research about patient-centred outcomes of the different AVR techniques.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Adult , Humans , Middle Aged , Aortic Valve/surgery , Retrospective Studies , Heart Valve Prosthesis Implantation/methods , Aortic Valve Insufficiency/surgery , Treatment Outcome , Aortic Valve Stenosis/surgery
12.
Article in English | MEDLINE | ID: mdl-37584674

ABSTRACT

OBJECTIVES: We present the long-term results of a trileaflet (Triflo) versus bileaflet (On-X) mechanical valve in both aortic and pulmonary positions in a sheep model. METHODS: The Triflo valve was implanted in 21 female sheep in aortic (n = 8) and pulmonary position (n = 13). The On-X valve was implanted in 7 female sheep in aortic (n = 1) and pulmonary (n = 6) positions. No antithrombotic medication of any kind was given postoperatively. In the aortic group, survival cohorts were 3 and 5 months. In the pulmonary group, survival cohorts were 10 and 20 weeks. Valve performance was assessed using haematology, echocardiography and acoustic measurements combined with post-mortem pathology analysis of the downstream organs. RESULTS: The mean gradients were lower for the Triflo valve in both pulmonary [4.30 mmHg (3.70-5.73) vs 6.80 mmHg (4.63-7.96), P = 0.012] and aortic [5.1 mmHg (4.2-7.7) vs 10.7 mmHg (8.7-12.9), P = 0.007] positions. Peak gradients were lower for the Triflo valve in both pulmonary [8.05 mmHg (6.75-10.23) vs 13.15 mmHg (9.20-14.76), P = 0.005] and aortic [8.7 mmHg (7.5-12.5) vs 16.5 mmHg (14.2-19.6), P = 0.009] positions. In both positions, leaflets and housing surface were free from any deposits macro- and microscopically and comparable to nonimplanted control valves. Peripheral organs showed no signs of thrombo-embolic damage. Biochemical and haematological were comparable to preoperative. The closing click sound pressure level of the Triflo was significantly lower in both aortic [108.4 sound pressure level (102.0-115.7) vs 111.7 sound pressure level (105.5-117.0), P < 0.001] and pulmonary [103.6 sound pressure level (99.1-108.9) vs 118.5 sound pressure level (116.7-120.2), P < 0.001] position. CONCLUSIONS: Preliminary in vivo results of the Triflo valve are promising in both aortic and pulmonary positions in an ovine model. Excellent haemodynamics, stable long-term function, low valve noise and no thrombo-embolic events in the absence of antithrombotic medication lay the foundation to a future clinical first-in-man trial.

13.
J Clin Med ; 12(15)2023 Jul 28.
Article in English | MEDLINE | ID: mdl-37568386

ABSTRACT

Valvular heart disease is a common disease often necessitating valve replacement. Mechanical heart valves (MHVs) are often used in younger patients because of their longer durability. Their main disadvantage is the need for lifelong anticoagulation. Warfarin is considered a standard treatment, but it is far from perfect. Direct oral anticoagulants (DOACs) are a new and more patient-friendly alternative to warfarin when anticoagulation is required, but have not yet been approved for the indication of mechanical valves. EVIDENCE ACQUISITION: A literature search of Pubmed, Embase, Web of Science (Core Collection), and Cochrane Library (from inception to May 2023) was performed using a search string that was well defined and not modified during the study. An extensive overview of the search terms used in each database can be found in the Appendix. Only prospective clinical trials were included in this review. A total of 10 publications were included in this review. RELEVANCE TO CLINICAL PRACTICE: This systematic review summarizes the different types of DOACs and their possible use in the anticoagulation of mechanical valves. We aim to propose future directions in anticoagulation research for mechanical valves. CONCLUSIONS: DOAC use in MHVs has been halted due to the failure of both dabigatran and apixaban in two major clinical trials. However, rivaroxaban was successful in two small clinical trials. Ample research is still needed to explore new valve designs as well as new anticoagulation targets.

15.
J Clin Anesth ; 87: 111088, 2023 08.
Article in English | MEDLINE | ID: mdl-37129976

ABSTRACT

STUDY OBJECTIVE: To investigate if an erector spinae plane (ESP) block decreases postoperative opioid consumption, pain and postoperative nausea and vomiting in patients undergoing robotically-assisted minimally invasive direct coronary artery bypass surgery (RAMIDCAB). DESIGN: A single-center, double-blind, prospective, randomized, placebo-controlled trial. SETTING: Postoperative period; operating room, post-anesthesia care unit (PACU) and hospital ward in a university hospital. PATIENTS: Sixty-four patients undergoing RAMIDCAB surgery via left-sided mini-thoracotomy and enrolled in the institutional enhanced recovery after cardiac surgery program. INTERVENTIONS: At the end of surgery, patients received an ESP catheter at vertebra T5 under ultrasound guidance and were randomized to the administration of either ropivacaine 0.5% (loading dose of 30 ml and three additional doses of 20 ml each, interspersed with a 6 h interval) or normal saline 0.9% (with an identical administration scheme). In addition, patients received multimodal analgesia including acetaminophen, dexamethasone and patient-controlled analgesia with morphine. Following the final ESP bolus and before catheter removal, the position of the catheter was re-evaluated by ultrasound. Patients, investigators and medical personnel were blinded for the group allocation during the entire trial. MEASUREMENTS: Primary outcome was cumulative morphine consumption during the first 24 h after extubation. Secondary outcomes included location and severity of pain, presence/extent of sensory block, duration of postoperative ventilation and hospital length of stay. Safety outcomes comprised the incidence of adverse events. MAIN RESULTS: Median (IQR) 24-h morphine consumption was not different between the intervention- and control-groups, 67 mg (35-84) versus 71 mg (52-90) (p = 0.25), respectively. Likewise, no differences were detected in secondary and safety endpoints. CONCLUSIONS: Following RAMIDCAB surgery, adding an ESP block to a standard multimodal analgesia regimen did not reduce opioid consumption and pain scores.


Subject(s)
Nerve Block , Robotic Surgical Procedures , Humans , Analgesics, Opioid/adverse effects , Pain, Postoperative/etiology , Pain, Postoperative/prevention & control , Robotic Surgical Procedures/adverse effects , Prospective Studies , Nerve Block/adverse effects , Nerve Block/methods , Morphine , Analgesia, Patient-Controlled/methods , Coronary Artery Bypass/adverse effects , Ultrasonography, Interventional/methods
16.
CVIR Endovasc ; 6(1): 10, 2023 Mar 02.
Article in English | MEDLINE | ID: mdl-36862221

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the feasibility of an endovascular repair, using the NEXUS™ Aortic Arch Stent Graft System, in a real-world cohort of patients, treated with a Frozen Elephant Trunk (FET) procedure for pathology involving the aortic arch. RESULTS: The preoperative computed tomography angiography scans of 37 patients were retrospectively analyzed using a dedicated workstation. In total, seven patients (N = 7/37; 18.9%) were eligible for endovascular repair. This number increased to eleven patients (N = 11/37; 29.7%) if an additional relining of the distal aorta would be performed. Device suitability was 47.1% in patients (N = 8/17; 47.1%) with aortic arch aneurysm, 12.5% (N = 1/8; 12.5%) in patients with an acute Stanford type A dissection and 50% (N = 2/4; 50%) in patients with Crawford type II thoraco-abdominal aneurysm. The stent graft was not suitable for any of the two patients with chronic type B dissection (N = 0/2; 0%). In 22 patients (N = 22/37; 59.5%) an endovascular repair with this type of stent graft was not feasible due to an inadequate proximal sealing zone. There was no suitable brachiocephalic trunk landing zone in 13 patients (N = 13/37; 35.1%). There was no suitable distal landing zone distal in 14 patients (N = 14/37; 36.8%). This number decreased to ten patients (N = 10/37; 27.0%) when considering an additional relining of the distal aorta. CONCLUSIONS: Endovascular repair with the NEXUS single branch stent graft is feasible in a minority of this real-world cohort that underwent a Frozen Elephant Trunk procedure. However, the applicability of this device probably improves in cases with isolated aortic arch aneurysms.

17.
J Clin Anesth ; 86: 111072, 2023 06.
Article in English | MEDLINE | ID: mdl-36807995

ABSTRACT

STUDY OBJECTIVE: To investigate if an erector spinae plane (ESP) block decreases postoperative opioid consumption, pain and postoperative nausea and vomiting in patients undergoing minimally invasive mitral valve surgery (MIMVS). DESIGN: A single-center, double-blind, prospective, randomized, placebo-controlled trial. SETTING: Postoperative period; operating room, post-anesthesia care unit (PACU) and hospital ward in a university hospital. PATIENTS: Seventy-two patients undergoing video-assisted thoracoscopic MIMVS via right-sided mini-thoracotomy and enrolled in the institutional enhanced recovery after cardiac surgery program. INTERVENTIONS: At the end of surgery, all patients received an ESP catheter at vertebra T5 under ultrasound guidance and were randomized to the administration of either ropivacaine 0.5% (loading of dose 30 ml and three additional doses of 20 ml with a 6 h interval) or normal saline 0.9% (with an identical administration scheme). In addition, patients received multimodal postoperative analgesia including dexamethasone, acetaminophen and patient-controlled intravenous analgesia with morphine. Following the final ESP bolus and before catheter removal, the position of the catheter was re-evaluated by ultrasound. Patients, investigators and medical personnel were blinded for the group allocation during the entire trial. MEASUREMENTS: Primary outcome was cumulative morphine consumption during the first 24 h after extubation. Secondary outcomes included severity of pain, presence/extent of sensory block, duration of postoperative ventilation and hospital length of stay. Safety outcomes comprised the incidence of adverse events. MAIN RESULTS: Median (IQR) 24-h morphine consumption was not different between the intervention- and control-group, 41 mg (30-55) versus 37 mg (29-50) (p = 0.70), respectively. Likewise, no differences were detected for secondary and safety endpoints. CONCLUSIONS: Following MIMVS, adding an ESP block to a standard multimodal analgesia regimen did not reduce opioid consumption and pain scores.


Subject(s)
Cardiac Surgical Procedures , Nerve Block , Humans , Analgesics, Opioid , Pain, Postoperative/etiology , Pain, Postoperative/prevention & control , Pain, Postoperative/drug therapy , Prospective Studies , Mitral Valve/surgery , Nerve Block/adverse effects , Nerve Block/methods , Morphine , Cardiac Surgical Procedures/adverse effects , Analgesia, Patient-Controlled/methods , Ultrasonography, Interventional/methods
18.
Heart ; 109(11): 832-838, 2023 05 15.
Article in English | MEDLINE | ID: mdl-36650042

ABSTRACT

OBJECTIVES: Differences in indication and technique make a randomised comparison between valve-sparing root replacement (VSRR) and personalised external aortic root support (PEARS) challenging. We performed a propensity score (PS)-matched comparison of PEARS and VSRR for syndromic root aneurysm. METHODS: Patients in the PEARS 200 Database and Aortic Valve Insufficiency and ascending aorta Aneurysm InternATiOnal Registry (undergoing VSRR) with connective tissue disease operated electively for root aneurysm <60 mm with aortic regurgitation (AR) <1/4 were included. Using a PS analysis, 80 patients in each cohort were matched. Survival, freedom from reintervention and from AR ≥2/4 were estimated using a Kaplan-Meier analysis. RESULTS: Median follow-up was 25 and 55 months for 159 PEARS and 142 VSRR patients. Seven (4.4%) patients undergoing PEARS required an intervention for coronary injury or impingement, resulting in one death (0.6%). After VSRR, there were no early deaths, 10 (7%) reinterventions for bleeding and 1 coronary intervention. Survival for matched cohorts at 5 years was similar (PEARS 98% vs VSRR 99%, p=0.99). There was no difference in freedom from valve or ascending aortic/arch reintervention between matched groups. Freedom from AR ≥2/4 at 5 years in the matched cohorts was 97% for PEARS vs 92% for VSRR (p=0.55). There were no type A dissections. CONCLUSIONS: VSRR and PEARS offer favourable mid-term survival, freedom from reintervention and preservation of valve function. Both treatments deserve their place in the surgical repertoire, depending on a patient's disease stage. This study is limited by its retrospective nature and different follow-ups in both cohorts.


Subject(s)
Aortic Aneurysm , Aortic Valve Insufficiency , Blood Vessel Prosthesis Implantation , Heart Valve Prosthesis Implantation , Humans , Aorta, Thoracic , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Blood Vessel Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Treatment Outcome
19.
Eur J Cardiothorac Surg ; 63(2)2023 02 03.
Article in English | MEDLINE | ID: mdl-36308450

ABSTRACT

OBJECTIVES: Our goal was to evaluate the outcome of valve-sparing root replacement (VSRR) and to compare the outcomes to those of patients having composite valve-graft conduit aortic root replacement (CVG-ARR) in a cohort of patients with aortic root aneurysm ± valve insufficiency, without valvular stenosis. Although valve-sparing procedures are preferable in young patients, there is a lack of comparative data in comparable patients. METHODS: The VSRR procedures were performed in 2005 patients, and 218 patients underwent a CVG-ARR procedure. Exclusion criteria included aortic dissection, endocarditis and valvular stenosis. Propensity score matching (3:1 ratio) was applied to compare VSRR (reimplantation 33% and remodelling 67%) and CVG-ARR. RESULTS: We matched 218 patients with CVG-ARR to 654 patients with VSRR (median age, 56.0; median follow-up was 4 years in both groups; interquartile range 1-5 years). Early mortality was 1.1% of those who had VSRR versus 2.3% in those who had CVG-ARR. Survival was 95.4% [95% confidence interval (CI) 94-97%] at 5 years in patients who had VSRR versus 85.4% (95% CI 82-92%) in those who had CVG-ARR; P = 0.002. Freedom from reintervention at 5 years was 96.8% (95% CI 95-98%) with VSRR and 95.4% (95% CI 91-99%) with CVG-ARR (P = 0.98). Additionally, there were more thromboembolic, endocarditis and bleeding events in the patients who had CVG-ARR (P = 0.02). CONCLUSIONS: This multicentre study shows excellent results after valve-sparing root replacement in patients with an ascending aortic aneurysm with or without valve insufficiency. Compared to composite valve-graft aortic root replacement, survival is better and valve-related events are fewer. Consequently, valve-sparing procedures should be considered whenever a durable repair is feasible. We advocate a valve-sparing strategy even in more complex cases when performed in experienced centres.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Root Aneurysm , Aortic Valve Insufficiency , Blood Vessel Prosthesis Implantation , Endocarditis , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Pilots , Humans , Middle Aged , Aortic Valve/surgery , Propensity Score , Constriction, Pathologic/etiology , Blood Vessel Prosthesis Implantation/methods , Aortic Aneurysm, Thoracic/surgery , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Endocarditis/surgery , Treatment Outcome , Retrospective Studies , Aortic Valve Insufficiency/surgery
20.
J Thorac Cardiovasc Surg ; 166(1): 156-166.e6, 2023 07.
Article in English | MEDLINE | ID: mdl-34876283

ABSTRACT

OBJECTIVE: In older patients, postoperative delirium is a frequently occurring complication after surgical aortic valve replacement, leading to an excess in postoperative morbidity and mortality. It remains controversial whether transcatheter aortic valve implantation and minimally invasive surgical aortic valve replacement can reduce the risk of postoperative delirium. This study aimed to compare the incidence of postoperative delirium after transcatheter aortic valve implantation and surgical aortic valve replacement and the impact on long-term outcomes. METHODS: Between September 2018 and January 2020, we conducted an observational, prospective cohort study in patients aged 70 years or more undergoing transcatheter aortic valve implantation or surgical aortic valve replacement. The primary end point was the incidence of in-hospital postoperative delirium during 5 postoperative days assessed with the Confusion Assessment Method. Secondary end points included perioperative inflammation, postoperative complications, health status (EuroQol 5-dimensional questionnaire 5 levels), and mortality up to 6 months. Transcatheter aortic valve implantation and surgical aortic valve replacement were compared using propensity weighting to account for important baseline differences (European System for Cardiac Operative Risk Evaluation II, age, and frailty). RESULTS: We included 250 patients with a mean (standard deviation) age of 80 (±5.8) years and a European System for Cardiac Operative Risk Evaluation score of 5 (±4.7). In the propensity-weighted analysis, those undergoing surgical aortic valve replacement (N = 166) had a higher incidence of postoperative delirium compared with transcatheter aortic valve implantation (N = 84) (51% vs 15%: P < .0001). Furthermore, patients undergoing surgical aortic valve replacement experienced more inflammation, a greater depth of anesthesia, and more intraoperative hypotension. After surgical aortic valve replacement, 41% of patients experienced an improved health status compared with 12% after transcatheter aortic valve implantation (P < .0001). No outcome differences were noted within the surgical aortic valve replacement groups. CONCLUSIONS: Transcatheter aortic valve implantation is associated with a lower risk for postoperative delirium. Nevertheless, patients undergoing surgical aortic valve replacement experience the greatest improvement in quality of life. Heart teams should consider these outcomes in shared decision-making in the choice of transcatheter aortic valve implantation or surgical aortic valve replacement.


Subject(s)
Aortic Valve Stenosis , Emergence Delirium , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aged , Aortic Valve/surgery , Emergence Delirium/complications , Heart Valve Prosthesis Implantation/methods , Quality of Life , Prospective Studies , Risk Assessment , Transcatheter Aortic Valve Replacement/methods , Risk Factors , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/surgery , Inflammation/complications
SELECTION OF CITATIONS