1.
Clin Transl Radiat Oncol ; 45: 100735, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38380115

ABSTRACT

Introduction: Tumor biopsy tissue response to ex vivo irradiation is potentially an interesting biomarker for in vivo tumor response, therefore, for treatment personalization. Tumor response ex vivo can be characterized by DNA damage response, expressed by the large-scale presence of DNA damage foci in tumor nuclei. Currently, characterizing tumor nuclei and DNA damage foci is a manual process that takes hours per patient and is subjective to inter-observer variability, which is not feasible in for clinical decision making. Therefore, our goal was to develop a method to automatically segment nuclei and DNA damage foci in tumor tissue samples treated with radiation ex vivo to characterize the DNA damage response, as potential biomarker for in vivo radio-sensitivity. Methods: Oral cavity tumor tissue of 21 patients was irradiated ex vivo (5 or 0 Gy), fixated 2 h post-radiation, and used to develop our method for automated nuclei and 53BP1 foci segmentation. The segmentation model used both deep learning and conventional image-analysis techniques. The training (22 %), validation (22 %), and test set (56 %) consisted of thousands of manually segmented nuclei and foci. The segmentations and number of foci per nucleus in the test set were compared to their ground truths. Results: The automatic nuclei and foci segmentations were highly accurate (Dice = 0.901 and Dice = 0.749, respectively). An excellent correlation (R2 = 0.802) was observed for the foci per nucleus that outperformed reported inter-observation variation. The analysis took âˆ¼ 8 s per image. Conclusion: This model can replace manual foci analysis for ex vivo irradiation of head-and-neck squamous cell carcinoma tissue, reduces the image-analysis time from hours to minutes, avoids the problem of inter-observer variability, enables assessment of multiple images or conditions, and provides additional information about the foci size. Thereby, it allows for reliable and rapid ex vivo radio-sensitivity assessment, as potential biomarker for response in vivo and treatment personalization.

2.
Int J Hyperthermia ; 34(7): 994-1001, 2018 11.
Article in English | MEDLINE | ID: mdl-29747544

ABSTRACT

PURPOSE: Radiotherapy (RT) treatment of locally-advanced and recurrent head and neck carcinoma (HNC) results in disappointing outcomes. Combination of RT with cisplatin or cetuximab improves survival but the increased toxicity and patient's comorbidity warrant the need for a less-toxic radiosensitizer. Stimulated by several randomized studies demonstrating the radio-sensitizing effect of hyperthermia, we developed the HYPERcollar. Here, we report early experience and toxicity in patients with advanced HNC. METHODS AND MATERIALS: 119 hyperthermia treatments given to 27 patients were analyzed. Hyperthermia was applied once a week by the HYPERcollar aimed at achieving 39-43 °C in the target area, up to patients' tolerance. Pre-treatment planning was used to optimize treatment settings. When possible, invasive thermometry catheters were placed. RESULTS: Mean power applied during the 119 hyperthermia treatments ranged from 120 to 1007 W (median 543 W). 15 (13%) hyperthermia treatments were not fully completed due to: pain allocated to hyperthermia (6/15), dyspnea from sticky saliva associated with irradiation (2/15) and unknown reasons (7/15). No severe complications or enhanced thermal or mucosal toxicities were observed. Excluding post-operative treatment, response rates after 3 months were 46% (complete) and 7% (partial). CONCLUSION: Hyperthermia with the HYPERcollar proved to be safe and feasible with good compliance and promising outcome.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Head and Neck Neoplasms/therapy , Hyperthermia, Induced/methods , Adolescent , Adult , Aged , Aged, 80 and over , Feasibility Studies , Female , Head and Neck Neoplasms/pathology , Humans , Male , Middle Aged , Young Adult
3.
Phys Med Biol ; 61(2): 488-503, 2016 Jan 21.
Article in English | MEDLINE | ID: mdl-26682777

ABSTRACT

The eye is considered to be a critical organ when determining safety standards for radio frequency (RF) radiation. Experimental data obtained using animals showed that RF heating of the eye, particularly over a specific threshold, can induce cataracts. During the treatment of cancer in the head and neck by hyperthermia, the eyes receive a considerable dose of RF radiation due to stray radiation from the prolonged (60 min) and intense exposure at 434 MHz of this region. In the current study, we verified the exposure guidelines for humans by determining the association between the electromagnetic and thermal dose in the eyes with the reported ocular effects. We performed a simulation study to retrospectively assess the specific absorption rate (SAR) and temperature increase in the eyes of 16 selected patients (encompassing a total of 74 treatment sessions) whose treatment involved high power delivery as well as a minimal distance between the tumor site and the eye. Our results show that the basic restrictions on the peak 10 g spatial-averaged SAR (10 W kg(-1)) and peak tissue temperature increase (1 °C) are exceeded by up to 10.4 and 4.6 times, on average, and by at least 6.2 and 1.8 times when considering the lower limit of the 95% confidence interval. Evaluation of the acute effects according to patients' feedback (all patients), the common toxicity criteria scores (all patients) and an ophthalmology investigation (one patient with the highest exposure) revealed no indication of any serious acute ocular effect, even though the eyes were exposed to high electromagnetic fields, leading to a high thermal dose. We also found that, although there is a strong correlation (R (2) = 0.88) between the predicted induced SAR and temperature in the eye, there are large uncertainties regarding the temperature-SAR relationship. Given this large uncertainty (129%) compared with the uncertainty of 3D temperature simulations (61%), we recommend using temperature simulations as a dosimetric measure in electromagnetic exposure risk assessments.


Subject(s)
Electromagnetic Fields/adverse effects , Eye/radiation effects , Head and Neck Neoplasms/radiotherapy , Radio Waves/adverse effects , Adult , Female , Humans , Male , Radiotherapy Dosage
5.
Phys Med Biol ; 60(3): 995-1006, 2015 Feb 07.
Article in English | MEDLINE | ID: mdl-25574664

ABSTRACT

To provide an adequate level of protection for humans from exposure to radio-frequency (RF) electromagnetic fields (EMF) and to assure that any adverse health effects are avoided. The basic restrictions in terms of the specific energy absorption rate (SAR) were prescribed by IEEE and ICNIRP. An example of a therapeutic application of non-ionizing EMF is hyperthermia (HT), in which intense RF energy is focused at a target region. Deep HT in the head and neck (H&N) region involves inducing energy at 434 MHz for 60 min on target. Still, stray exposure of the brain is considerable, but to date only very limited side-effects were observed. The objective of this study is to investigate the stringency of the current basic restrictions by relating the induced EM dose in the brain of patients treated with deep head and neck (H&N) HT to the scored acute health effects. We performed a simulation study to calculate the induced peak 10 g spatial-averaged SAR (psSAR10g) in the brains of 16 selected H&N patients who received the highest SAR exposure in the brain, i.e. who had the minimum brain-target distance and received high forwarded power during treatment. The results show that the maximum induced SAR in the brain of the patients can exceed the current basic restrictions (IEEE and ICNIRP) on psSAR10g for occupational environments by 14 times. Even considering the high local SAR in the brain, evaluation of acute effects by the common toxicity criteria (CTC) scores revealed no indication of a serious acute neurological effect. In addition, this study provides pioneering quantitative human data on the association between maximum brain SAR level and acute adverse effects when brains are exposed to prolonged RF EMF.


Subject(s)
Brain/radiation effects , Electromagnetic Fields/adverse effects , Fever/etiology , Head/radiation effects , Neck/radiation effects , Radio Waves/adverse effects , Humans
6.
FEBS Lett ; 195(1-2): 179-84, 1986 Jan 20.
Article in English | MEDLINE | ID: mdl-3002851

ABSTRACT

Recently, we have reported the isolation of cDNAs encoding the precursors of insulin-like growth factors I and II (IGF-I and II) [(1983) Nature 306, 609-611; (1985) FEBS Lett. 179, 243-246. These cDNAs were employed as specific probes to detect and isolate the corresponding genes from human cosmid DNA libraries. Three cosmids were detected, together containing the entire cDNA sequence of IGF-I, and one cosmid containing the sequence of IGF-II cDNA. Southern blot hybridization, physical mapping and nucleotide sequence analysis of these cosmids revealed that the IGF-I and -II genes have a discontinous structure. The IGF-I gene contains at least four exons spanning a region of probably more that 45 kilobasepairs (kb), while the IGF-II gene consists of at least five exons, spanning a region of 16 kb.


Subject(s)
Chromosomes, Human, 6-12 and X , Insulin-Like Growth Factor II/genetics , Insulin-Like Growth Factor I/genetics , Somatomedins/genetics , Amino Acid Sequence , Base Sequence , Chromosome Mapping , DNA/genetics , DNA Restriction Enzymes , Genes , Humans