Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 22(15)2022 Jul 30.
Article in English | MEDLINE | ID: mdl-35957277

ABSTRACT

Neutrons constitute a significant component of the secondary cosmic rays and are one of the most important contributors to natural cosmic ray radiation background dose. The study of the cosmic ray neutrons' contribution to the dose equivalent received by humans is an interesting and challenging task for the scientific community. In addition, international regulations demand assessing the biological risk due to radiation exposure for both workers and the general population. Because the dose rate due to cosmic radiation increases significantly with altitude, the objective of this work was to characterize the thermoluminescent dosimeter (TLDs) from the perspective of exposing them at high altitudes for longtime neutron dose monitoring. The pair of TLD-700 and TLD-600 is amply used to obtain the information on gamma and neutron dose in mixed neutron-gamma fields due to the present difference in 6Li isotope concentration. A thermoluminescence dosimeter system based on pair of TLD-600/700 was characterized to enable it for neutron dosimetry in the thermal energy range. The system was calibrated in terms of neutron ambient dose equivalent in an experimental setup using a 241Am-B radionuclide neutron source coated by a moderator material, polyethylene, creating a thermalized neutron field. Afterward, the pair of TLD-600/700 was exposed at the CERN-EU High-Energy Reference Field (CERF) facility in Geneva, which delivers a neutron field with a spectrum similar to that of secondary cosmic rays. The dosimetric system provided a dose value comparable with the calculated one demonstrating a good performance for neutron dosimetry.


Subject(s)
Americium , Radiation Dosimeters , Altitude , Humans , Neutrons , Radiation Dosage , Thermoluminescent Dosimetry
2.
J Environ Radioact ; 208-209: 105993, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31238239

ABSTRACT

Because of the geomagnetic field shape, the polar regions are the most exposed to secondary particles and radiation produced by primary cosmic rays in the atmosphere. At present, only few experimental measurements of environmental dose are reported in literature at high southern latitudes. A three year campaign has been carried out in two different locations, Ushuaia (Argentina, 54.80∘ S, 68.30∘ W) and Marambio (Antarctica, 64.24∘ S, 56.63∘ W), using a Liulin type detector, allowing to measure the total environmental radiation flux and dose. The Liulin type instrument, measuring the energy deposition in a silicon detector, is especially suitable to evaluate the dose, separating the low and high LET (Linear Energy Transfer) components. The instrument was installed at the GAW Station in Ushuaia and inside the LAMBI Laboratory at the Marambio Antarctic base. In December 2017 preliminary measurements have been carried out at the French-Italian base Dome C, at 3233 m a.s.l., with a Liulin-AR, a new version of Liulin spectrometer, specifically built for this application by the Space Research and Technology Institute of Bulgarian Academy of Sciences. In this paper the environmental dose values obtained in the different southern high latitude locations are compared and discussed.


Subject(s)
Radiation Dosage , Radiation Monitoring , Radiometry , Antarctic Regions , Argentina , Atmosphere
SELECTION OF CITATIONS
SEARCH DETAIL
...