Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Front Bioeng Biotechnol ; 10: 958582, 2022.
Article in English | MEDLINE | ID: mdl-36159671

ABSTRACT

The miniaturization of laboratory procedures for Lab-on-Chip (LoC) devices and translation to various platforms such as single cell analysis or Organ-on-Chip (OoC) systems are revolutionizing the life sciences and biomedical fields. As a result, microfluidics is becoming a viable technology for improving the quality and sensitivity of critical processes. Yet, standard test methods have not yet been established to validate basic manufacturing steps, performance, and safety of microfluidic devices. The successful development and widespread use of microfluidic technologies are greatly dependent on the community's success in establishing widely supported test protocols. A key area that requires consensus guidelines is leakage testing. There are unique challenges in preventing and detecting leaks in microfluidic systems because of their small dimensions, high surface-area to volume ratios, low flow rates, limited volumes, and relatively high-pressure differentials over short distances. Also, microfluidic devices often employ heterogenous components, including unique connectors and fluid-contacting materials, which potentially make them more susceptible to mechanical integrity failures. The differences between microfluidic systems and traditional macroscale technologies can exacerbate the impact of a leak on the performance and safety on the microscale. To support the microfluidics community efforts in product development and commercialization, it is critical to identify common aspects of leakage in microfluidic devices and standardize the corresponding safety and performance metrics. There is a need for quantitative metrics to provide quality assurance during or after the manufacturing process. It is also necessary to implement application-specific test methods to effectively characterize leakage in microfluidic systems. In this review, different methods for assessing microfluidics leaks, the benefits of using different test media and materials, and the utility of leakage testing throughout the product life cycle are discussed. Current leakage testing protocols and standard test methods that can be leveraged for characterizing leaks in microfluidic devices and potential classification strategies are also discussed. We hope that this review article will stimulate more discussions around the development of gas and liquid leakage test standards in academia and industry to facilitate device commercialization in the emerging field of microfluidics.

2.
Biosensors (Basel) ; 12(7)2022 Jun 24.
Article in English | MEDLINE | ID: mdl-35884254

ABSTRACT

Electrochemical impedance spectroscopy (EIS) is widely accepted as an effective and non-destructive method to assess cell health during cell-culture. However, there is a lack of compact devices compatible with microfluidic integration and microscopy that could provide the real-time and non-invasive monitoring of cell-cultures using EIS. In this paper, we reported the design and characterization of a modular EIS testing system based on a patented technology. This device was fabricated using easily processable methodologies including screen-printing of the impedance electrodes and molding or micromachining of the cell culture chamber with an easy assembly procedure. Accordingly, to obtain processable, biocompatible and sterilizable electrode materials that lower the impact of interfacial impedance on TEER (Transepithelial electrical resistance) measurements, and to enable concomitant microscopy observations, we optimized the formulation of the electrode inks and the design of the EIS electrodes, respectively. First, electrode materials were based on carbon biocompatible inks enriched with IrOx particles to obtain low interfacial impedance electrodes approaching the performances of classical non-biocompatible Ag/AgCl second-species electrodes. Secondly, we proposed three original electrode designs, which were compared to classical disk electrodes that were optically compatible with microscopy. We assessed the impact of the electrode design on the response of the impedance sensor using COMSOL Multiphysics. Finally, the performance of the impedance spectroscopy devices was assessed in vitro using human airway epithelial cell cultures.


Subject(s)
Dielectric Spectroscopy , Microfluidics , Cell Culture Techniques , Electric Impedance , Electrodes , Humans
3.
Talanta ; 229: 122275, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-33838777

ABSTRACT

There is a growing need for real-time monitoring of metabolic products that could reflect cell damages over extended periods. In this paper, we report the design and development of an original multiparametric (bio)sensing platform that is tailored for the real-time monitoring of cell metabolites derived from cell cultures. Most attractive features of our developed electrochemical (bio)sensing platform are its easy manufacturing process, that enables seamless scale-up, modular and versatile approach, and low cost. In addition, the developed platform allows a multiparametric analysis instead of single-analyte analysis. Here we provide an overview of the sensors-based analysis of four main factors that can indicate a possible cell deterioration problem during cell-culture: pH, hydrogen peroxide, nitric oxide/nitrite and lactate. Herein, we are proposing a sensors platform based on thick-film coupled to microfluidic technology that can be integrated into any microfluidic system using Luer-lock connectors. This platform allows obtaining an accurate analysis of the secreting stress metabolites during cell/tissues culture.


Subject(s)
Biosensing Techniques , Microfluidics , Cell Culture Techniques , Hydrogen Peroxide , Lactic Acid , Nitrites
4.
Sci Rep ; 8(1): 17762, 2018 12 10.
Article in English | MEDLINE | ID: mdl-30531826

ABSTRACT

Deterministic lateral displacement (DLD) has been extensively implemented in the last decade for size-based sample preparation, owing to its high separation performances for a wide range of particle dimensions. However, separating particles from 1 µm to 10 µm in one single DLD device is challenging because of the required diversity of pillar dimensions and inherent fabrication issues. This paper presents an alternative approach to achieve the extraction of E. coli bacteria from blood samples spiked with prostate cancer cells. Our approach consists in cascading individual DLD devices in a single automated platform, using flexible chambers that successively collect and inject the sample between each DLD stage without any external sample manipulation. Operating DLD separations independently enables to maximize the sorting efficiency at each step, without any disturbance from downstream stages. The proposed two-step automated protocol is applied to the separation of three types of components (bacteria, blood particles and cancer cells), with a depletion yield of 100% for cancer cells and 93% for red blood cells. This cascaded approach is presented for the first time with two DLD modules and is upscalable to improve the dynamic range of currently available DLD devices.


Subject(s)
Erythrocytes/microbiology , Prostatic Neoplasms/blood , Prostatic Neoplasms/microbiology , Cell Line, Tumor , Cell Separation/methods , Erythrocyte Count/methods , Escherichia coli/isolation & purification , Humans , Male , Microfluidic Analytical Techniques , PC-3 Cells , Particle Size
5.
PLoS One ; 13(5): e0197629, 2018.
Article in English | MEDLINE | ID: mdl-29768490

ABSTRACT

Particle separation in microfluidic devices is a common problematic for sample preparation in biology. Deterministic lateral displacement (DLD) is efficiently implemented as a size-based fractionation technique to separate two populations of particles around a specific size. However, real biological samples contain components of many different sizes and a single DLD separation step is not sufficient to purify these complex samples. When connecting several DLD modules in series, pressure balancing at the DLD outlets of each step becomes critical to ensure an optimal separation efficiency. A generic microfluidic platform is presented in this paper to optimize pressure balancing, when DLD separation is connected either to another DLD module or to a different microfluidic function. This is made possible by generating droplets at T-junctions connected to the DLD outlets. Droplets act as pressure controllers, which perform at the same time the encapsulation of DLD sorted particles and the balance of output pressures. The optimized pressures to apply on DLD modules and on T-junctions are determined by a general model that ensures the equilibrium of the entire platform. The proposed separation platform is completely modular and reconfigurable since the same predictive model applies to any cascaded DLD modules of the droplet-based cartridge.


Subject(s)
Microfluidic Analytical Techniques/methods , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques/instrumentation , Microfluidics , Microscopy, Fluorescence/methods
6.
Small ; 13(37)2017 10.
Article in English | MEDLINE | ID: mdl-28783259

ABSTRACT

Deterministic lateral displacement (DLD) devices enable to separate nanometer to micrometer-sized particles around a cutoff diameter, during their transport through a microfluidic channel with slanted rows of pillars. In order to design appropriate DLD geometries for specific separation sizes, robust models are required to anticipate the value of the cutoff diameter. So far, the proposed models result in a single cutoff diameter for a given DLD geometry. This paper shows that the cutoff diameter actually varies along the DLD channel, especially in narrow pillar arrays. Experimental and numerical results reveal that the variation of the cutoff diameter is induced by boundary effects at the channel side walls, called the wall effect. The wall effect generates unexpected particle trajectories that may compromise the separation efficiency. In order to anticipate the wall effect when designing DLD devices, a predictive model is proposed in this work and has been validated experimentally. In addition to the usual geometrical parameters, a new parameter, the number of pillars in the channel cross dimension, is considered in this model to investigate its influence on the particle trajectories.

7.
Nano Lett ; 7(3): 813-7, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17302459

ABSTRACT

This paper reports for the first time on the reversible electrowetting of liquid droplets in air and oil environments on superhydrophobic silicon nanowires (SiNWs). The silicon nanowires were grown on Si/SiO2 substrates using the vapor-liquid-solid (VLS) mechanism, electrically insulated using 300 nm SiO2, and hydrophobized by coating with a fluoropolymer C4F8. The resulting surfaces displayed liquid contact angle (Theta) around 160 degrees for a saline solution (100 mM KCl) in air with almost no hysteresis. Electrowetting induced a maximum reversible decrease of the contact angle of 23 degrees at 150 VTRMS in air.

SELECTION OF CITATIONS
SEARCH DETAIL
...