Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Vet Comp Orthop Traumatol ; 28(5): 323-30, 2015.
Article in English | MEDLINE | ID: mdl-26219753

ABSTRACT

OBJECTIVES: The number of locking screws required per fragment during bridging osteosynthesis in the dog has not been determined. The purpose of this study was to assess the survival of two constructs, with either two or three screws per fragment, under cyclic torsion. METHODS: Ten-hole 3.5 mm stainless steel locking compression plates (LCP) were fixed 1 mm away from bone surrogates with a fracture gap of 47 mm using two bicortical locking screws (10 constructs) or three bicortical locking screws (10 constructs) per fragment, placed at the extremities of each LCP. Constructs were tested in cyclic torsion (range: 0 to +0.218 rad) until failure. RESULTS: The 3-screws constructs (29.65 ± 1.89 N.m/rad) were stiffer than the 2-screws constructs (23.73 ± 0.87 N.m/rad), and therefore, were subjected to a greater torque during cycling (6.05 ± 1.33 N.m and 4.88 ± 1.14 N.m respectively). The 3-screws constructs sustained a significantly greater number of cycles (20,700 ± 5,735 cycles) than the 2-screws constructs (15,600 ± 5,272 cycles). In most constructs, failure was due to screw damage at the junction of the shaft and head. The remaining constructs failed because of screw head unlocking, sometimes due to incomplete seating of the screw head prior to testing. CLINICAL SIGNIFICANCE: Omitting the third innermost locking screw during bridging osteosynthesis led to a reduction in fatigue life of 25% and construct stiffness by 20%. Fracture of the screws is believed to occur sequentially, starting with the innermost screw that initially shields the other screws.


Subject(s)
Bone Plates/veterinary , Bone Screws/veterinary , Dogs/surgery , Animals , Bone Plates/standards , Bone Screws/standards , Dogs/injuries , Equipment Failure Analysis , Fractures, Bone/surgery , Fractures, Bone/veterinary , Torsion, Mechanical
2.
Vet Comp Orthop Traumatol ; 26(6): 479-88, 2013.
Article in English | MEDLINE | ID: mdl-24080774

ABSTRACT

OBJECTIVES: To compare the mechanical properties of locking compression plate (LCP) and limited contact dynamic compression plate (LC-DCP) constructs in an experimental model of comminuted fracture of the canine femur during eccentric cyclic loading. METHODS: A 20 mm mid-diaphyseal gap was created in eighteen canine femora. A 10-hole, 2.4 mm stainless steel plate (LCP or LC-DCP) was applied with three bicortical screws in each bone fragment. Eccentric cyclic loadings were applied at 10 Hertz for 610,000 cycles. Quasistatic loading / unloading cycles were applied at 0 and 10,000 cycles, and then every 50,000 cycles. Structural stiffness was calculated as the slope of the linear portion of the load-displacement curves during quasistatic loading / unloading cycles. RESULTS: No bone failure or screw loosening occurred. Two of the nine LCP constructs failed by plate breakage during fatigue testing, whereas no gross failure occurred with the LC-DCP constructs. The mean first stiffness of the LCP constructs over the course of testing was 24.0% lower than that of constructs stabilized by LC-DCP. Construct stiffness increased in some specimens during testing, presumably due to changes in bone-plate contact. The first stiffness of LC-DCP constructs decreased by 19.4% and that of locked constructs by 34.3% during the cycling period. A biphasic stiffness profile was observed: the second stiffness was significantly greater than the first stiffness in both groups, which allowed progressive stabilization at elevated load levels. CLINICAL SIGNIFICANCE: Because LCP are not compressed to the bone, they may have a longer working length across a fracture, and thus be less stiff. However, this may cause them to be more susceptible to fatigue failure if healing is delayed.


Subject(s)
Bone Plates/veterinary , Dogs , Animals , Biomechanical Phenomena , Cadaver , Compressive Strength , Equipment Failure Analysis , Femur , Prosthesis Design , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL