Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 19(4): e0301991, 2024.
Article in English | MEDLINE | ID: mdl-38626094

ABSTRACT

The aim of this study is to define atrial fibrillation (AF) prevalence and incidence rates across minority groups in the United States (US), to aid in diversity enrollment target setting for randomized controlled trials. In AF, US minority groups have lower clinically detected prevalence compared to the non-Hispanic or Latino White (NHW) population. We assess the impact of ascertainment bias on AF prevalence estimates. We analyzed data from adults in Optum's de-identified Clinformatics® Data Mart Database from 2017-2020 in a cohort study. Presence of AF at baseline was identified from inpatient and/or outpatient encounters claims using validated ICD-10-CM diagnosis algorithms. AF incidence and prevalence rates were determined both in the overall population, as well as in a population with a recent stroke event, where monitoring for AF is assumed. Differences in prevalence across cohorts were assessed to determine if ascertainment bias contributes to the variation in AF prevalence across US minority groups. The period prevalence was respectively 4.9%, 3.2%, 2.1% and 5.9% in the Black or African American, Asian, Hispanic or Latino, and NHW population. In patients with recent ischemic stroke, the proportion with AF was 32.2%, 24.3%, 25%, and 24.5%, respectively. The prevalence of AF among the stroke population was approximately 7 to 10 times higher than the prevalence among the overall population for the Asian and Hispanic or Latino population, compared to approximately 5 times higher for NHW patients. The relative AF prevalence difference of the Asian and Hispanic or Latino population with the NHW population narrowed from respectively, -46% and -65%, to -22% and -24%. The study findings align with previous observational studies, revealing lower incidence and prevalence rates of AF in US minority groups. Prevalence estimates of the adult population, when routine clinical practice is assumed, exhibit higher prevalence differences compared to settings in which monitoring for AF is assumed, particularly among Asian and Hispanic or Latino subgroups.


Subject(s)
Atrial Fibrillation , Stroke , Adult , Humans , Atrial Fibrillation/epidemiology , Atrial Fibrillation/diagnosis , Cohort Studies , Hispanic or Latino , Minority Groups , Randomized Controlled Trials as Topic , Stroke/epidemiology , United States/epidemiology , Black or African American , Asian , White , Bias
2.
PLoS One ; 19(3): e0300109, 2024.
Article in English | MEDLINE | ID: mdl-38466688

ABSTRACT

Slow patient enrollment or failing to enroll the required number of patients is a disruptor of clinical trial timelines. To meet the planned trial recruitment, site selection strategies are used during clinical trial planning to identify research sites that are most likely to recruit a sufficiently high number of subjects within trial timelines. We developed a machine learning approach that outperforms baseline methods to rank research sites based on their expected recruitment in future studies. Indication level historical recruitment and real-world data are used in the machine learning approach to predict patient enrollment at site level. We define covariates based on published recruitment hypotheses and examine the effect of these covariates in predicting patient enrollment. We compare model performance of a linear and a non-linear machine learning model with common industry baselines that are constructed from historical recruitment data. Performance of the methodology is evaluated and reported for two disease indications, inflammatory bowel disease and multiple myeloma, both of which are actively being pursued in clinical development. We validate recruitment hypotheses by reviewing the covariates relationship with patient recruitment. For both indications, the non-linear model significantly outperforms the baselines and the linear model on the test set. In this paper, we present a machine learning approach to site selection that incorporates site-level recruitment and real-world patient data. The model ranks research sites by predicting the number of recruited patients and our results suggest that the model can improve site ranking compared to common industry baselines.


Subject(s)
Machine Learning , Humans , Patient Selection , Clinical Trials as Topic
3.
IEEE Trans Neural Netw Learn Syst ; 29(1): 167-182, 2018 01.
Article in English | MEDLINE | ID: mdl-27831891

ABSTRACT

This paper analyzes data-based online nonlinear extremum-seeker (DONE), an online optimization algorithm that iteratively minimizes an unknown function based on costly and noisy measurements. The algorithm maintains a surrogate of the unknown function in the form of a random Fourier expansion. The surrogate is updated whenever a new measurement is available, and then used to determine the next measurement point. The algorithm is comparable with Bayesian optimization algorithms, but its computational complexity per iteration does not depend on the number of measurements. We derive several theoretical results that provide insight on how the hyperparameters of the algorithm should be chosen. The algorithm is compared with a Bayesian optimization algorithm for an analytic benchmark problem and three applications, namely, optical coherence tomography, optical beam-forming network tuning, and robot arm control. It is found that the DONE algorithm is significantly faster than Bayesian optimization in the discussed problems while achieving a similar or better performance.

4.
Biomed Opt Express ; 8(4): 2261-2275, 2017 Apr 01.
Article in English | MEDLINE | ID: mdl-28736670

ABSTRACT

In this report, which is an international collaboration of OCT, adaptive optics, and control research, we demonstrate the Data-based Online Nonlinear Extremum-seeker (DONE) algorithm to guide the image based optimization for wavefront sensorless adaptive optics (WFSL-AO) OCT for in vivo human retinal imaging. The ocular aberrations were corrected using a multi-actuator adaptive lens after linearization of the hysteresis in the piezoelectric actuators. The DONE algorithm succeeded in drastically improving image quality and the OCT signal intensity, up to a factor seven, while achieving a computational time of 1 ms per iteration, making it applicable for many high speed applications. We demonstrate the correction of five aberrations using 70 iterations of the DONE algorithm performed over 2.8 s of continuous volumetric OCT acquisition. Data acquired from an imaging phantom and in vivo from human research volunteers are presented.

5.
Opt Lett ; 40(24): 5722-5, 2015 Dec 15.
Article in English | MEDLINE | ID: mdl-26670496

ABSTRACT

Several sensor-less wavefront aberration correction methods that correct nonlinear wavefront aberrations by maximizing the optical coherence tomography (OCT) signal are tested on an OCT setup. A conventional coordinate search method is compared to two model-based optimization methods. The first model-based method takes advantage of the well-known optimization algorithm (NEWUOA) and utilizes a quadratic model. The second model-based method (DONE) is new and utilizes a random multidimensional Fourier-basis expansion. The model-based algorithms achieve lower wavefront errors with up to ten times fewer measurements. Furthermore, the newly proposed DONE method outperforms the NEWUOA method significantly. The DONE algorithm is tested on OCT images and shows a significantly improved image quality.


Subject(s)
Image Enhancement/methods , Models, Theoretical , Optical Phenomena , Tomography, Optical Coherence/methods , Algorithms , Artifacts , Signal-To-Noise Ratio
6.
Opt Express ; 22(26): 32406-18, 2014 Dec 29.
Article in English | MEDLINE | ID: mdl-25607203

ABSTRACT

The transfer function for optical wavefront aberrations in single-mode fiber based optical coherence tomography is determined. The loss in measured OCT signal due to optical wavefront aberrations is quantified using Fresnel propagation and the calculation of overlap integrals. A distinction is made between a model for a mirror and a scattering medium model. The model predictions are validated with measurements on a mirror and a scattering medium obtained with an adaptive optics optical coherence tomography setup. Furthermore, a one-step defocus correction, based on a single A-scan measurement, is derived from the model and verified. Finally, the pseudo-convex structure of the optical coherence tomography transfer function is validated with the convergence of a hill climbing algorithm. The implications of this model for wavefront sensorless aberration correction are discussed.


Subject(s)
Algorithms , Image Enhancement/instrumentation , Lenses , Models, Theoretical , Tomography, Optical Coherence/instrumentation , Computer Simulation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Feedback , Light , Scattering, Radiation
SELECTION OF CITATIONS
SEARCH DETAIL
...