Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharmacol Toxicol Methods ; 66(2): 114-24, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22521338

ABSTRACT

INTRODUCTION: This study was designed to provide a comprehensive nonclinical respiratory safety pharmacology assessment using respiratory inductance plethysmography (RIP) concomitant with a standard cardiovascular (CV) safety assessment in non-human primates (NHP) in a single cardiorespiratory study. METHODS: RIP calibration data were generated in conscious, ketamine-sedated, or propofol-anesthetized NHP to determine the most appropriate method. Calibration accuracy was assessed using a CO(2) rebreathe maneuver. Regardless of the technique, the RIP system reliably demonstrated accurate assessment of the CO(2) rebreathe response when expressed as a percent change with respect to control. Four male NHP were given single oral doses of vehicle, 1.25 and 5 mg/kg test article followed by 20 mg/kg repeatedly for 7 days. Telemetry-derived cardiovascular parameters (PR, QRS, QT, heart rate corrected QT (QTcR) intervals, blood pressure [BP], and heart rate [HR]) and RIP-derived respiratory parameters (respiration rate [RR], tidal volume [TV], and minute volume [MV]) were determined for 24 h pretest, 2 h predose and 24 h postdose. RESULTS: A single dose of the test article at 5 or 20 mg/kg was associated with slight increases in HR, BP, RR, and MV at 2 to 7 h postdose, followed by decreases in HR, RR, TV, and MV at 5-23 h postdose. Decreases in HR, RR, TV, and MV were observed following 7 days of dosing at 20 mg/kg. Slight QTcR prolongation at 1 to 11 h postdose was observed following a single dose of 20 mg/kg. CONCLUSION: These data show that the integrated assessment of cardiovascular and respiratory parameters in NHP is achievable continuously for at least 24 h postdose. The use of RIP as a method to assess the effects of a novel compound on the respiratory system complements, but does not interfere with, the cardiovascular assessment of new drugs.


Subject(s)
Cardiovascular Physiological Phenomena/drug effects , Cardiovascular System/drug effects , Drug-Related Side Effects and Adverse Reactions , Haplorhini/physiology , Animals , Animals, Laboratory , Calibration , Consciousness , Dose-Response Relationship, Drug , Drug Evaluation, Preclinical , Hemodynamics/drug effects , Male , Models, Animal , Plethysmography , Pulmonary Ventilation/drug effects , Pulmonary Ventilation/physiology , Telemetry/methods , Tidal Volume/drug effects , Tidal Volume/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...