Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Med Res Methodol ; 22(1): 147, 2022 05 20.
Article in English | MEDLINE | ID: mdl-35596151

ABSTRACT

BACKGROUND: Accelerometery is commonly used to estimate physical activity, sleep, and sedentary behavior. In free-living conditions, periods of device removal (non-wear) can lead to misclassification of behavior with consequences for research outcomes and clinical decision making. Common methods for non-wear detection are limited by data transformations (e.g., activity counts) or algorithm parameters such as minimum durations or absolute temperature thresholds that risk over- or under-estimating non-wear time. This study aimed to advance non-wear detection methods by integrating a 'rate-of-change' criterion for temperature into a combined temperature-acceleration algorithm. METHODS: Data were from 39 participants with neurodegenerative disease (36% female; age: 45-83 years) who wore a tri-axial accelerometer (GENEActiv) on their wrist 24-h per day for 7-days as part of a multi-sensor protocol. The reference dataset was derived from visual inspection conducted by two expert analysts. Linear regression was used to establish temperature rate-of-change as a criterion for non-wear detection. A classification and regression tree (CART) decision tree classifier determined optimal parameters separately for non-wear start and end detection. Classifiers were trained using data from 15 participants (38.5%). Outputs from the CART analysis were supplemented based on edge cases and published parameters. RESULTS: The dataset included 186 non-wear periods (85.5% < 60 min). Temperature rate-of-change over the first five minutes of non-wear was - 0.40 ± 0.17 °C/minute and 0.36 ± 0.21 °C/minute for the first five minutes following device donning. Performance of the DETACH (DEvice Temperature and Accelerometer CHange) algorithm was improved compared to existing algorithms with recall of 0.942 (95% CI 0.883 to 1.0), precision of 0.942 (95% CI 0.844 to 1.0), F1-Score of 0.942 (95% CI 0.880 to 1.0) and accuracy of 0.996 (0.994-1.000). CONCLUSION: The DETACH algorithm accurately detected non-wear intervals as short as five minutes; improving non-wear classification relative to current interval-based methods. Using temperature rate-of-change combined with acceleration results in a robust algorithm appropriate for use across different temperature ranges and settings. The ability to detect short non-wear periods is particularly relevant to free-living scenarios where brief but frequent removals occur, and for clinical application where misclassification of behavior may have important implications for healthcare decision-making.


Subject(s)
Accelerometry , Neurodegenerative Diseases , Acceleration , Accelerometry/methods , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Sedentary Behavior , Temperature
2.
J Neurol ; 269(5): 2673-2686, 2022 May.
Article in English | MEDLINE | ID: mdl-34705114

ABSTRACT

BACKGROUND: Remote health monitoring with wearable sensor technology may positively impact patient self-management and clinical care. In individuals with complex health conditions, multi-sensor wear may yield meaningful information about health-related behaviors. Despite available technology, feasibility of device-wearing in daily life has received little attention in persons with physical or cognitive limitations. This mixed methods study assessed the feasibility of continuous, multi-sensor wear in persons with cerebrovascular (CVD) or neurodegenerative disease (NDD). METHODS: Thirty-nine participants with CVD, Alzheimer's disease/amnestic mild cognitive impairment, frontotemporal dementia, Parkinson's disease, or amyotrophic lateral sclerosis (median age 68 (45-83) years, 36% female) wore five devices (bilateral ankles and wrists, chest) continuously for a 7-day period. Adherence to device wearing was quantified by examining volume and pattern of device removal (non-wear). A thematic analysis of semi-structured de-brief interviews with participants and study partners was used to examine user acceptance. RESULTS: Adherence to multi-sensor wear, defined as a minimum of three devices worn concurrently, was high (median 98.2% of the study period). Non-wear rates were low across all sensor locations (median 17-22 min/day), with significant differences between some locations (p = 0.006). Multi-sensor non-wear was higher for daytime versus nighttime wear (p < 0.001) and there was a small but significant increase in non-wear over the collection period (p = 0.04). Feedback from de-brief interviews suggested that multi-sensor wear was generally well accepted by both participants and study partners. CONCLUSION: A continuous, multi-sensor remote health monitoring approach is feasible in a cohort of persons with CVD or NDD.


Subject(s)
Cardiovascular Diseases , Neurodegenerative Diseases , Parkinson Disease , Wearable Electronic Devices , Aged , Feasibility Studies , Female , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...