Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Arch Phys Med Rehabil ; 104(12): 2051-2058, 2023 12.
Article in English | MEDLINE | ID: mdl-37270023

ABSTRACT

OBJECTIVE: To investigate whether preoperative expectations regarding performing work-related knee-straining activities were associated with being dissatisfied 6 months after total knee arthroplasty (TKA) among working patients, and, to identify prognostic factors for being dissatisfied with performing these work-related knee-straining activities. DESIGN: Multicenter prospective cohort study. SETTING: Orthopedic surgery departments of 7 hospitals in the Netherlands. PARTICIPANTS: A consecutive sample of 175 working patients who were on the waiting list for TKA (median age 59 years, 53% women) and intended to return to work (N=175). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURE(S): Dissatisfaction with performing work-related knee-straining activities 6 months postoperative was measured using the Work Osteoarthritis or joint-Replacement Questionnaire (score range 0-100). The clinically relevant cut-off points for being satisfied and dissatisfied were ≥71 and ≤50, respectively. RESULTS: Thirty-three patients (19%) were dissatisfied with performing work-related knee-straining activities 6 months after TKA. Patients who expected to be dissatisfied preoperative had a 5.1 times higher odds (95% CI 1.7-15.5) of being dissatisfied 6 months postoperatively compared with patients who expected to be satisfied preoperative. Regression analyses revealed that only patients' expectations were prognostic for being dissatisfied 6 months postoperatively rather than age, pain level, or having a knee-straining job. CONCLUSIONS: Two in 10 working patients are dissatisfied with performing work-related knee-straining activities 6 months after TKA. Only preoperative patients' expectations appeared prognostic. Therefore, we should better prepare working patients with low expectations by managing their preoperative expectations and improving their performance of work-related knee-straining activities in rehabilitation.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Humans , Female , Middle Aged , Male , Prospective Studies , Patient Satisfaction , Prognosis , Osteoarthritis, Knee/surgery , Motivation , Treatment Outcome
2.
Hip Int ; : 1120700020939075, 2020 Jul 07.
Article in English | MEDLINE | ID: mdl-32634064

ABSTRACT

OBJECTIVE: Does the use of staples or sutures for wound closure have a lower surgical site infection rate in patients receiving primary total hip arthroplasty (THA)? DESIGN: Prospective, randomised controlled multicentre trial. METHODS: 535 patients undergoing THA were included and randomised into 2 groups: 268 wounds were closed with staples, and 267 with sutures. Primary outcome was surgical site infection (SSI). Secondary outcomes were prosthetic joint infection (PJI), other wound complications (dehiscence, necrosis and prolonged drainage) and duration of admittance. Follow-up occurred at 2, 6, and 12 weeks, and at 1 year. RESULTS: There were no significant demographic differences between the 2 groups. SSI occurred more frequently when wounds were closed with staples (4% compared to 1% with sutures; OR 2.8; CI, 0.885-0.952; p = 0.057). SSI was treated with oral antibiotics. The staples group showed significantly more wound complications (17% compared to 5%; OR 3.943, CI 2.073-7.498; p = 0.000). Wound discharge was significantly prolonged in the staples group (n = 40, compared to n = 12 in the sutures group; OR 3.728; CI, 1.909-7.281; p = 0.000). There was no significant difference in PJI (p = 0.364). CONCLUSIONS: In this large RCT comparing staples with sutures after THA, the use of staples is associated with a nearly 3 times greater risk of SSI (OR 2.8; p = 0.057). Staples significantly prolong wound discharge. The use of sutures for wound closure after THA is advised. Trial registration: Staples Or Sutures trial (S.O.S. trial) http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=3946 , NTR3946.

3.
J Occup Rehabil ; 29(3): 585-594, 2019 09.
Article in English | MEDLINE | ID: mdl-30539374

ABSTRACT

Purpose Three out of ten patients do not return to work after total knee arthroplasty (TKA). Patient expectations are suggested to play a key role. What are patients' expectations regarding the ability to perform work-related knee-demanding activities 6 months after TKA compared to their preoperative status? Methods A multi-center cross-sectional study was performed among 292 working patients listed for TKA. The Work Osteoarthritis or joint-Replacement Questionnaire (WORQ, range 0-100, minimal important difference 13) was used to assess the preoperatively experienced and expected ability to perform work-related knee-demanding activities 6 months postoperatively. Differences between the preoperative and expected WORQ scores were tested and the most difficult knee-demanding work-related activities were described. Results Two hundred thirty-six working patients (81%) completed the questionnaire. Patients' expected WORQ score (Median = 75, IQR 60-86) was significantly (p < 0.01) higher than their preoperative WORQ score (Median = 44, IQR 35-56). A clinical improvement in ability to perform work-related knee-demanding activities was expected by 72% of the patients, while 28% of the patients expected no clinical improvement or even worse ability to perform work-related knee-demanding activities 6 months after TKA. Of the patients, 34% expected severe difficulty in kneeling, 30% in crouching and 17% in clambering 6 months after TKA. Conclusions Most patients have high expectations, especially regarding activities involving deep knee flexion. Remarkably, three out of ten patients expect no clinical improvement or even a worse ability to perform work-related knee-demanding activities 6 months postoperatively compared to their preoperative status. Therefore, addressing patients expectations seems useful in order to assure realistic expectations regarding work activities.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Motivation , Return to Work/psychology , Arthroplasty, Replacement, Knee/psychology , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Surveys and Questionnaires , Time Factors , Work Capacity Evaluation
4.
J Arthroplasty ; 20(3): 362-8, 2005 Apr.
Article in English | MEDLINE | ID: mdl-15809956

ABSTRACT

Between January 1987 and December 1990, 221 Zweymüller cementless total hip arthroplasties were performed in 211 patients with idiopathic osteoarthritis. A total of 136 patients (142 prostheses) were evaluated at a mean follow-up of 134 months (SD 9.5). The study group consisted of 78 Hochgezogen and 64 Stepless stem prostheses, all with a threaded titanium cup and ceramic head. No clinical and radiological differences were found between the 2 stem prostheses. Seven cups had been revised because of aseptic loosening; 17 cups showed radiolucent lines, osteolysis, or migration. Mean linear polyethylene wear of 105 (74%) cups was 0.46 mm (SD 0.27), with an annual wear of 0.04 mm (SD 0.02). Wear did not correlate with pain, cup migration, radiolucent lines, or osteolysis. Cumulative survival was 96%. Zweymüller cementless total hip arthroplasty showed good midterm results.


Subject(s)
Equipment Failure Analysis , Hip Prosthesis , Osteoarthritis, Hip/surgery , Postoperative Complications/diagnostic imaging , Aged , Bone Cements , Ceramics , Equipment Failure Analysis/statistics & numerical data , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteoarthritis, Hip/diagnostic imaging , Osteolysis/diagnostic imaging , Osteolysis/surgery , Postoperative Complications/surgery , Prosthesis Design , Radiography , Reoperation , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL
...