1.
Trials ; 25(1): 331, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773658

ABSTRACT

BACKGROUND: Self-monitoring of glucose is an essential component of type 1 diabetes (T1D) management. In recent years, continuous glucose monitoring (CGM) has provided an alternative to daily fingerstick testing for the optimisation of insulin dosing and general glucose management in people with T1D. While studies have been conducted to evaluate the impact of CGM on clinical outcomes in the US, Europe and Australia, there are limited data available for low- and middle-income countries (LMICs) and further empirical evidence is needed to inform policy decision around their use in these countries. METHODS: This trial was designed as a pragmatic, parallel-group, open-label, multicentre, three-arm, randomised (1:1:1) controlled trial of continuous or periodic CGM device use versus standard of care in people with T1D in South Africa and Kenya. The primary objective of this trial will be to assess the impact of continuous or periodic CGM device use on glycaemic control as measured by change from baseline glycosylated haemoglobin (HbA1c). Additional assessments will include clinical outcomes (glucose variation, time in/below/above range), safety (adverse events, hospitalisations), quality of life (EQ-5D, T1D distress score, Glucose Monitoring Satisfaction Survey for T1D), and health economic measures (incremental cost-effectiveness ratios, quality adjusted life years). DISCUSSION: This trial aims to address the substantial evidence gap on the impact of CGM device use on clinical outcomes in LMICs, specifically South Africa and Kenya. The trial results will provide evidence to inform policy and treatment decisions in these countries. TRIAL REGISTRATION: NCT05944731 (Kenya), July 6, 2023; NCT05944718 (South Africa), July 13, 2023.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Diabetes Mellitus, Type 1 , Glycated Hemoglobin , Multicenter Studies as Topic , Pragmatic Clinical Trials as Topic , Humans , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/drug therapy , Diabetes Mellitus, Type 1/diagnosis , Blood Glucose Self-Monitoring/instrumentation , Kenya , Blood Glucose/metabolism , Blood Glucose/analysis , Blood Glucose/drug effects , Glycated Hemoglobin/metabolism , Glycated Hemoglobin/analysis , South Africa , Quality of Life , Glycemic Control/instrumentation , Hypoglycemic Agents/therapeutic use , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/adverse effects , Implementation Science , Insulin/administration & dosage , Insulin/therapeutic use , Treatment Outcome , Cost-Benefit Analysis , Continuous Glucose Monitoring
2.
J Diabetes Sci Technol ; : 19322968241238146, 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38477255

ABSTRACT

BACKGROUND: Usability engineering analyzes the interaction between the intended users and a device. Its implementation is mandatory for manufacturers to obtain regulatory approval for the European market. The aim of this evaluation was assessing the role of usability testing in the development process. For this purpose, a continuous glucose monitoring (CGM) device under development was investigated to determine whether it could be used safely and effectively by the intended users. METHODS: Conduct of the usability testing was based on the international standard IEC 62366-1. Medical device use of CGM-experienced and non-experienced users (n = 15 each) was observed without initial training in use scenarios containing 18 tasks. The success rate of task completion was determined and the System Usability Scale (SUS) score was calculated from a questionnaire. A prototype of the FiberSense CGM System (EyeSense GmbH, Großostheim, Germany), comprising of a single-use sensor and a reusable detector, was investigated. RESULTS: Most use errors made by both user groups were related to ease of handling of the reusable detectors. The SUS scores achieved in this study were below the pre-defined SUS score acceptance criterion of ≥68. The most frequently mentioned reason for use errors was an incomprehensible and non-chronological instructions for use (IFU). CONCLUSIONS: The evaluation provides valuable insights on how to improve usability of the prototype device and demonstrates the value of conducting structured usability testing prior to product finalization. The results reflected areas for improvement of the user interface, mainly by restructuring the IFU, provision of an additional leaflet, and device training prior to use.

3.
BMC Health Serv Res ; 24(1): 401, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38553724

ABSTRACT

BACKGROUND: Point-of-care testing (POCT) devices are diagnostic tools that can provide quick and accurate results within minutes, making them suitable for diagnosing non-communicable diseases (NCDs). However, these devices are not widely implemented in healthcare systems and for this reason is relevant to understand the implementation process. AIM: To describe the process and define a strategy to implement a multiparameter POCT device for diagnosing and managing NCDs in one region of Peru. METHODS: A descriptive and non-experimental study, using the participatory methodologies of co-creation process. It was conducted in one region of Peru (Tumbes) to design an intervention for implementing a multiparameter POCT device. Two co-creation sessions were conducted involving five groups: community members, primary healthcare workers, these groups in both rural and urban settings, and regional decision-makers. These sessions included activities to understand patient journeys in receiving care for NCDs, identify facilitators and barriers to POCT devices usage, and define an implementation strategy for POCT devices in both rural and urban settings of Tumbes. The research team analysed the data and summarized key topics for discussion after each session. RESULTS: A total of 78 participants were enrolled across the five groups. Among community members: 22.2% had only diabetes, 24.1% had only hypertension, and 18.5% had both diagnoses. In the patient journey, community members mentioned that it took at least three days to receive a diagnosis and treatment for an NCD. Most of the participants agreed that the POCT devices would be beneficial for their communities, but they also identified some concerns. The strategy for POCT devices implementation included healthcare workers training, POCT devices must be placed in the laboratory area and must be able to perform tests for glucose, glycated haemoglobin, cholesterol, and creatinine. Advertising about POCT devices should be displayed at the healthcare centres and the municipality using billboards and flyers. CONCLUSIONS: The co-creation process was useful to develop strategies for the implementation of multiparameter POCT devices for NCDs, involving the participation of different groups of stakeholders guided by moderators in both, rural and urban, settings in Peru.


Subject(s)
Diabetes Mellitus , Noncommunicable Diseases , Humans , Noncommunicable Diseases/epidemiology , Noncommunicable Diseases/therapy , Peru , Point-of-Care Testing , Diabetes Mellitus/diagnosis , Diabetes Mellitus/therapy , Primary Health Care , Point-of-Care Systems
4.
EClinicalMedicine ; 70: 102492, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38481788

ABSTRACT

Background: Patients with COVID-19 that had diagnosed chronic diseases - including diabetes - may experience higher rates of hospitalisation and mortality relative to the general population. However, the burden of undiagnosed co-morbidities during the pandemic has not been adequately studied. Methods: We developed a model to estimate the hospitalisation and mortality burden of patients with COVID-19 that had undiagnosed type 1 and type 2 diabetes (UD). The retrospective analytical modelling framework was informed by country-level demographic, epidemiological and COVID-19 data and parameters. Eight low-and middle-income countries (LMICs) were studied: Brazil, China, India, Indonesia, Mexico, Nigeria, Pakistan, and South Africa. The modelling period consisted of the first phase of the pandemic - starting from the date when a country identified its first COVID case to the date when the country reached 1% coverage with one dose of a COVID-19 vaccine. The end date ranged from Jan 20, 2021 for China to June 2, 2021 for Nigeria. Additionally, we estimated the change in burden under a scenario in which all individuals with UD had been diagnosed prior to the pandemic. Findings: Based on our modelling estimates, across the eight countries, 6.7 (95% uncertainty interval: 3.4-11.3) million COVID-19 hospitalised patients had UD of which 1.9 (0.9-3.4) million died. These represented 21.1% (13.4%-30.1%) of all COVID-19 hospitalisations and 30.5% (14.3%-55.5%) of all COVID-19 deaths in these countries. Based on modelling estimates, if these populations had been diagnosed for diabetes prior to the COVID-19 pandemic, 1.7% (-3.0% to 5.9%) of COVID-19 hospitalisations and 5.0% (-0.9% to 14.1%) of COVID-19 deaths could have been prevented, and 1.8 (-0.3 to 5.0) million quality-adjusted life years gained. Interpretation: Our findings suggest that undiagnosed diabetes contributed substantially to COVID-19 hospitalisations and deaths in many LMICs. Funding: This work was supported, in part, by the Bill & Melinda Gates Foundation [INV-029062] and FIND.

6.
BMJ Open ; 14(2): e076685, 2024 Feb 17.
Article in English | MEDLINE | ID: mdl-38367964

ABSTRACT

AIMS: Development of non-invasive and minimally invasive glucose monitoring devices (NI-MI-GMDs) generally takes place in high-income countries (HICs), with HIC's attributes guiding product characteristics. However, people living with diabetes (PLWD) in low-income and middle-income countries (LMICs) encounter different challenges to those in HICs. This study aimed to define requirements for NI-MI-GMDs in LMICs to inform a target product profile to guide development and selection of suitable devices. METHODS: This was a multiple-methods, exploratory, qualitative study conducted in Kyrgyzstan, Mali, Peru and Tanzania. Interviews and group discussions/activities were conducted with healthcare workers (HCWs), adults living with type 1 (PLWD1) or type 2 diabetes (PLWD2), adolescents living with diabetes and caregivers. RESULTS: Among 383 informants (90 HCW, 100 PLWD1, 92 PLWD2, 24 adolescents, 77 caregivers), a range of differing user requirements were reported, including preferences for area of glucose measurement, device attachment, data display, alert type and temperature sensitivity. Willingness to pay varied across countries; common requirements included ease of use, a range of guiding functions, the possibility to attach to a body part of choice and a cost lower than or equal to current glucose self-monitoring. CONCLUSIONS: Ease-of-use and affordability were consistently prioritised, with broad functionality required for alarms, measurements and attachment possibilities. Perspectives of PLWD are crucial in developing a target product profile to inform characteristics of NI-MI-GMDs in LMICs. Stakeholders must consider these requirements to guide development and selection of NI-MI-GMDs at country level, so that devices are fit for purpose and encourage frequent glucose monitoring among PLWD in these settings.


Subject(s)
Developing Countries , Diabetes Mellitus, Type 2 , Adult , Adolescent , Humans , Diabetes Mellitus, Type 2/therapy , Tanzania , Kyrgyzstan , Mali , Peru , Blood Glucose Self-Monitoring , Blood Glucose
7.
BMC Public Health ; 23(1): 2291, 2023 11 20.
Article in English | MEDLINE | ID: mdl-37986070

ABSTRACT

BACKGROUND: South Africa grapples with a substantial burden of non-communicable diseases (NCDs), particularly type 2 diabetes (diabetes) and hypertension. However, these conditions are often underdiagnosed and poorly managed, further exacerbated by the strained primary healthcare (PHC) system and the disruptive impact of the COVID-19 pandemic. Integrating NCD screening with large-scale healthcare initiatives, such as COVID-19 vaccination campaigns, offers a potential solution, especially in low- and middle-income countries (LMICs). We investigated the feasibility and effectiveness of this integration. METHODS: A prospective cohort study was conducted at four government health facilities in Johannesburg, South Africa. NCD screening was incorporated into the COVID-19 vaccination campaign. Participants underwent COVID-19 rapid tests, blood glucose checks, blood pressure assessments, and anthropometric measurements. Those with elevated blood glucose or blood pressure values received referrals for diagnostic confirmation at local PHC centers. RESULTS: Among 1,376 participants screened, the overall diabetes prevalence was 4.1%, combining previously diagnosed cases and newly identified elevated blood glucose levels. Similarly, the hypertension prevalence was 19.4%, comprising pre-existing diagnoses and newly detected elevated blood pressure cases. Notably, 46.1% of participants displayed waist circumferences indicative of metabolic syndrome, more prevalent among females. Impressively, 7.8% of all participants screened were potentially newly diagnosed with diabetes or hypertension. Approximately 50% of individuals with elevated blood glucose or blood pressure successfully linked to follow-up care within four weeks. CONCLUSION: Our study underscores the value of utilizing even brief healthcare interactions as opportunities for screening additional health conditions, thereby aiding the identification of previously undiagnosed cases. Integrating NCD screenings into routine healthcare visits holds promise, especially in resource-constrained settings. Nonetheless, concerted efforts to strengthen care linkage are crucial for holistic NCD management and control. These findings provide actionable insights for addressing the NCD challenge and improving healthcare delivery in LMICs.


Subject(s)
COVID-19 , Diabetes Mellitus, Type 2 , Diabetes Mellitus , Hypertension , Noncommunicable Diseases , Female , Humans , COVID-19 Vaccines , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/epidemiology , Blood Glucose/metabolism , South Africa/epidemiology , Point-of-Care Systems , Noncommunicable Diseases/epidemiology , Pandemics , Prospective Studies , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/prevention & control , Hypertension/diagnosis , Hypertension/epidemiology , Hypertension/prevention & control , Diabetes Mellitus/epidemiology
8.
Res Sq ; 2023 Oct 10.
Article in English | MEDLINE | ID: mdl-37886557

ABSTRACT

Background: Non-communicable diseases (NCDs) are responsible for 51% of total mortality in South Africa, with a rising burden of hypertension (HTN) and diabetes mellitus (DM). Incorporating NCD and COVID-19 screening into mass activities such as COVID-19 vaccination programs could offer significant long-term benefits for early detection interventions. However, there is limited knowledge of the associated costs and resources required. We evaluated the cost of integrating NCD screening and COVID-19 antigen rapid diagnostic testing (Ag-RDT) into a COVID-19 vaccination program. Methods: We conducted a prospective cost analysis at three public sector primary healthcare clinics and one academic hospital in Johannesburg, South Africa, conducting vaccinations. Participants were assessed for eligibility and recruited during May-Dec 2022. Costs were estimated from the provider perspective using a bottom-up micro-costing approach and reported in 2022 USD. Results: Of the 1,376 enrolled participants, 240 opted in to undergo a COVID-19 Ag-RDT, and none tested positive for COVID-19. 138 (10.1%) had elevated blood pressure, with 96 (70%) having no prior HTN diagnosis. 22 (1.6%) were screen-positive for DM, with 12 (55%) having no prior diagnosis. The mean and median costs per person screened for NCDs were $2.53 (SD: 3.62) and $1.70 (IQR: $1.38-$2.49), respectively. The average provider cost per person found to have elevated blood glucose levels and blood pressure was $157.99 and $25.19, respectively. Finding a new case of DM and HTN was $289.65 and $36.21, respectively. For DM and DM + HTN screen-positive participants, diagnostic tests were the main cost driver, while staff costs were the main cost driver for - and HTN screen-positive and screen-negative participants. The mean and median cost per Ag-RDT was $6.13 (SD: 0.87) and $5.95 (IQR: $5.55-$6.25), with costs driven mainly by test kit costs. Conclusions: We show the cost of finding new cases of DM and HTN in a vaccine queue, which is an essential first step in understanding the feasibility and resource requirements for such initiatives. However, there is a need for comparative economic analyses that include linkage to care and retention data to fully understand this cost and determine whether opportunistic screening should be added to general mass health activities.

9.
J Diabetes Sci Technol ; : 19322968231159657, 2023 Feb 22.
Article in English | MEDLINE | ID: mdl-37758681

ABSTRACT

BACKGROUND: FIND, the global alliance for diagnostics, identified the nonmarket-approved continuous glucose monitoring (CGM) system, FiberSense system (FBS), as a potential device for use in low- and middle-income countries. Together with two market-approved, factory-calibrated CGM systems, namely, the FreeStyle Libre 2 (FL2) and the GlucoRx AiDEX (ADX), the FBS was subjected to a clinical performance evaluation. METHODS: Thirty adult participants with type 1 diabetes were enrolled. The study was mainly conducted at home, with three in-clinic sessions conducted over the study period of 28 days. Comparator measurements were collected from capillary samples, using a high-quality blood glucose monitoring system. RESULTS: Data from 31, 70, and 78 sensors of FBS, FL2, and ADX, respectively, were included in the performance analysis. The mean absolute relative differences between CGM and comparator data for FBS, FL2, and ADX were 14.7%, 9.2%, and 21.9%, and relative biases were -2.1%, -2.5%, and -18.5%, respectively. Analysis of individual sensor accuracy revealed low, moderate, and high sensor-to-sensor variability for FBS, FL2, and ADX, respectively. Sensor survival probabilities until the end of sensor life were 47.2% for FBS (28 days), 71.3% for FL2 (14 days), and 48.4% for ADX (14 days). CONCLUSIONS: The results of FBS were encouraging enough to conduct further performance and usability evaluations in a low- and middle-income country. The results of FL2 mainly agreed with existing studies, whereas ADX showed substantial deviations from previously reported results.

10.
PLOS Glob Public Health ; 3(8): e0001982, 2023.
Article in English | MEDLINE | ID: mdl-37585432

ABSTRACT

The World Health Organization (WHO) has called for the elimination of cervical cancer as a public health problem. Cervical cancer screening through human papillomavirus (HPV) testing is a core component of the strategy for elimination, with a set target of screening 70% of women twice in their lifetimes. In this review, we discuss technical barriers and opportunities to increase HPV screening globally.

11.
PLoS One ; 18(7): e0287794, 2023.
Article in English | MEDLINE | ID: mdl-37418394

ABSTRACT

AIMS: We sought to evaluate the yield and linkage-to-care for diabetes and hypertension screening alongside a study assessing the use of rapid antigen tests for COVID-19 in taxi ranks in Johannesburg, South Africa. METHODS: Participants were recruited from Germiston taxi rank. We recorded results of blood glucose (BG), blood pressure (BP), waist circumference, smoking status, height, and weight. Participants who had elevated BG (fasting ≥7.0; random ≥11.1mmol/L) and/or BP (diastolic ≥90 and systolic ≥140mmHg) were referred to their clinic and phoned to confirm linkage. RESULTS: 1169 participants were enrolled and screened for elevated BG and elevated BP. Combining participants with a previous diagnosis of diabetes (n = 23, 2.0%; 95% CI:1.3-2.9%) and those that had an elevated BG measurement (n = 60, 5.2%; 95% CI:4.1-6.6%) at study enrollment, we estimated an overall indicative prevalence of diabetes of 7.1% (95% CI:5.7-8.7%). When combining those with known hypertension at study enrollment (n = 124, 10.6%; 95% CI:8.9-12.5%) and those with elevated BP (n = 202; 17.3%; 95% CI:15.2-19.5%), we get an overall prevalence of hypertension of 27.9% (95% CI:25.4-30.1%). Only 30.0% of those with elevated BG and 16.3% of those with elevated BP linked-to-care. CONCLUSION: By opportunistically leveraging existing COVID-19 screening in South Africa to screen for diabetes and hypertension, 22% of participants received a potential new diagnosis. We had poor linkage-to-care following screening. Future research should evaluate options for improving linkage-to-care, and evaluate the large-scale feasibility of this simple screening tool.


Subject(s)
Autonomic Nervous System Diseases , COVID-19 , Diabetes Mellitus, Type 2 , Hypertension , Humans , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/epidemiology , South Africa/epidemiology , Point-of-Care Systems , COVID-19/diagnosis , COVID-19/epidemiology , Hypertension/diagnosis , Hypertension/epidemiology , Blood Pressure , Risk Factors , Prevalence
12.
BMC Med Educ ; 23(1): 483, 2023 Jun 29.
Article in English | MEDLINE | ID: mdl-37386440

ABSTRACT

BACKGROUND: In Southeast Asia, pharmacies are critical sources of healthcare advice for under-served communities, including those with/at risk of diabetes. AIM: Explore knowledge/practices relating to diabetes and blood glucose monitoring (BGM) among pharmacy professionals in Cambodia and Viet Nam, using digital professional education to address gaps. METHODS: An online survey was distributed to pharmacy professionals in Cambodia and Viet Nam registered on SwipeRx mobile application. Eligible participants dispensed medicines and/or were involved in purchasing products, and worked at retail pharmacies stocking ≥ 1 BGM product. An accredited continuing professional development module was then made available to pharmacy professionals and students on SwipeRx in both countries. After completing the 1-2 h module, users were required to correctly answer ≥ 60% (Cambodia) or ≥ 70% (Viet Nam) of knowledge assessment questions to achieve accreditation units from local partners. RESULTS: Whereas 33% of survey respondents in Cambodia (N = 386) and 63% in Viet Nam (N = 375) reported performing blood glucose testing at the pharmacy, only 19% and 14% were aware that clients taking multiple daily doses of insulin should check blood glucose levels several times a day. Of 1,137 and 399 pharmacy professionals/students who completed the module and passed the assessment in Cambodia and Viet Nam, 1,124 (99%) and 376 (94%) received accreditation. Knowledge levels improved substantially in 10 of 14 learning areas in Cambodia and 6 of 10 in Viet Nam. CONCLUSIONS: Digital education can strengthen pharmacy professional capacity to provide comprehensive and accurate information on diabetes management and the awareness of quality BGM products in Southeast Asia.


Subject(s)
Diabetes Mellitus , Pharmacies , Pharmacy , Humans , Blood Glucose , Cambodia , Vietnam , Blood Glucose Self-Monitoring , Diabetes Mellitus/drug therapy , Diabetes Mellitus/epidemiology
13.
BMC Health Serv Res ; 23(1): 412, 2023 Apr 28.
Article in English | MEDLINE | ID: mdl-37118750

ABSTRACT

BACKGROUND: Point-of-care testing (POCT) devices may facilitate the delivery of rapid and timely results, providing a clinically important advantage in patient management. The challenges and constraints in the implementation process, considering different levels of actors have not been much explored. This scoping review aimed to assess literature pertaining to implementation facilitators and barriers of POCT devices for the diagnosis or monitoring of cardiometabolic diseases. METHODS: A scoping review of the literature was conducted. The inclusion criteria were studies on the inception, planning, or implementation of interventions with POCT devices for the diagnosis or monitoring of cardiometabolic diseases defined as dyslipidemia, cardiovascular diseases, type 2 diabetes, and chronic kidney disease. We searched MEDLINE, Embase, and Global Health databases using the OVID searching engine until May 2022. The Consolidated Framework of Implementation Research (CFIR) was used to classify implementation barriers and facilitators in five constructs. Also, patient, healthcare professional (HCP), and organization level was used. RESULTS: Twenty studies met the eligibility criteria for data extraction. All studies except two were conducted in high-income countries. Some findings are: 1) Intervention: the most widely recognized facilitator was the quick turnaround time with which results are obtained. 2) Outer setting: at the organizational level, the lack of clear regulatory and accreditation mechanisms has hindered the adoption and sustainability of the use of POCT. 3) Inner setting: for HCP, performing POCT during the consultation was both a facilitator and a barrier in terms of time, personnel, and service delivery. 4) Individuals: the implementation of POCT may generate stress and discomfort in some HCP in terms of training and new responsibilities. 5) Process: for patients, it is highly appreciated that obtaining the sample was simple and more comfortable if venipuncture was not used. CONCLUSION: This scoping review has described the facilitators and barriers of implementing a POCT device for cardiometabolic conditions using the CFIR. The information can be used to design better strategies to implement these devices and benefit more populations that have low access to cardiometabolic tests.


Subject(s)
Diabetes Mellitus, Type 2 , Point-of-Care Systems , Humans , Health Personnel , Point-of-Care Testing
14.
Hypertension ; 80(5): 1110-1116, 2023 05.
Article in English | MEDLINE | ID: mdl-36912176

ABSTRACT

BACKGROUND: To identify and summarize the global research literature on validation of automated noninvasive blood pressure measurement devices (BPMDs) with upper arm cuff, develop a repository of validated BPMDs in compliance with the 2020 World Health Organization technical specifications, and identify challenges and gaps in evidence base on validated BPMDs. METHODS: A scoping review was conducted. Primary research validating BPMDs complying with the 2020 World Health Organization technical specifications (ie, semiautomated/automated noninvasive devices with upper arm cuff), published in English between January 2000 and December 2021, was included. We searched MEDLINE, Web of Science, Scopus, EMBASE, CINAHL, CENTRAL, ProQuest and the dabl website. RESULTS: We included 269 studies validating 251 BPMDs across 89 manufacturers. Omron (29%), Microlife (10%), and A&D Company (8%) were the top 3 manufacturers. The 3 most frequently used validation protocols were the European Society of Hypertension-international protocol 2002 (27%), European Society of Hypertension-international protocol 2010 (25%), and modified British Hypertension Society protocol 1993 (16%), respectively. Nearly 45% of the validated BPMDs were intended for use in clinical settings, 38% were for home or self-measurement use, and 48% were for general adults. Most studies reported that BPMDs passed the validation criteria. There was inadequate reporting across studies, especially pertaining to validation settings. CONCLUSIONS: Most BPMDs fulfilled the validation criteria. However, there are considerable gaps in BPMD research in terms of geographical representation, including specific target populations and diseases/conditions, and a range of arm circumferences. Additionally, a potential strategy is required to accelerate the adoption of the Association for the Advancement of Medical Instrumentation (AAMI)/European Society of Hypertension/International Organization for Standardization Universal Standard (International Organization for Standardization 81060-2:2018) for BPMD validation.


Subject(s)
Blood Pressure Determination , Hypertension , Adult , Humans , Blood Pressure , Blood Pressure Determination/methods , Sphygmomanometers , World Health Organization , Blood Pressure Monitors
15.
Diabet Med ; 40(6): e15089, 2023 06.
Article in English | MEDLINE | ID: mdl-36929661

ABSTRACT

AIMS: The use of continuous glucose monitors (CGMs) has been shown to have positive impact on diabetes management for people with type 1 diabetes (T1DM), type 2 diabetes (T2DM) and gestational diabetes (GDM) in high-income countries. However, as useful as CGMs are, the experience in low- and middle-income countries (LMICs) is limited and has not been summarized. METHODS: A scoping review of the scientific literature was conducted. Medline, Embase, Global Health and Scopus were used to seek original research conducted in LMICs. The search results were screened by two reviewers independently. We included studies assessing health outcomes following the use of CGMs at the individual level (e.g. glycaemic control or complications) and at the health system level (e.g. barriers, facilitators and cost-effectiveness) in English, Portuguese, Spanish and French. Results were summarized narratively. RESULTS: From 4772 records found in database search, 27 reports were included; most of them from China (n = 7), Colombia (n = 5) and India (n = 4). Thirteen reports studied T1DM, five T2DM, seven both T1DM and T2DM and two GDM. Seven reports presented results of experimental studies (five randomized trials and two quasi-experimental); two on cost-effective analysis and the remaining 18 were observational. Studies showed that CGMs improved surrogate glycaemic outcomes (HbA1c reduction), hard endpoints (lower hospitalization rates and diabetes complications) and patient-oriented outcomes (quality of life). However, several caveats were identified: mostly observational studies, few participants in trials, short follow-up and focused on surrogate outcomes. CONCLUSIONS: The scoping review identified that studies about CGMs in LMICs have several limitations. Stronger study designs, appropriate sample sizes and the inclusion of patient-important outcomes should be considered to inform the evidence about CGMs for the management of people with diabetes in LMICs.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetes Mellitus, Type 2 , Diabetes, Gestational , Pregnancy , Female , Humans , Diabetes Mellitus, Type 2/epidemiology , Diabetes Mellitus, Type 2/therapy , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 1/therapy , Diabetes Mellitus, Type 1/complications , Developing Countries , Quality of Life , Blood Glucose/analysis
16.
Clin Chem Lab Med ; 61(6): 1015-1024, 2023 05 25.
Article in English | MEDLINE | ID: mdl-36704916

ABSTRACT

OBJECTIVES: Laboratory diagnostic services are essential to drive evidence-based treatment decisions, manage outbreaks, and provide population-level data. Many low- and middle-income countries (LMICs) lack sufficient diagnostic capacity, often further exacerbated in conflict-affected areas. This project assessed laboratory services in conflict-affected LMICs to understand gaps and opportunities for improving laboratory capacity. METHODS: The World Health Organization Laboratory Assessment Tool Facility Questionnaire (WHO Laboratory Tool) and Stepwise Laboratory Improvement Process Towards Accreditation (SLIPTA) checklist were used to assess five laboratories in Eastern Democratic Republic of the Congo (DRC) and five in Gaza, Palestine. Total scores and percentage outcomes by indicator were calculated. RESULTS: Average WHO Laboratory Tool score across all facilities was 41% (range 32-50%) in DRC and 78% (range 72-84%) in Gaza. Lowest scoring indicators in DRC were Biorisk management (13%, range 8-21%), Documentation (14%, range 6-21%), and in Gaza, were Facilities (59%, range 46-75%) and Documentation (60%, range 44-76%). Highest scoring indicators in DRC were Facilities (70%, range 45-83%) and Data and Information Management (61%, range 38-80%), and in Gaza were Data Information and Management (96%) and Public Health Function (91%, range 88-94%). In DRC, no laboratory achieved a SLIPTA star rating. In Gaza, two laboratories had a 3-star SLIPTA rating, one had a 2-star rating and two had a 1-star rating. CONCLUSIONS: Laboratory systems in conflict-affected LMICs have significant gaps. Implementating improvement strategies in such settings may be especially challenging.


Subject(s)
Laboratories , Public Health , Humans , Disease Outbreaks , World Health Organization , Accreditation
17.
PLoS Med ; 19(12): e1004111, 2022 12.
Article in English | MEDLINE | ID: mdl-36472973

ABSTRACT

BACKGROUND: Cardiovascular diseases (CVDs) are the leading cause of mortality globally with almost a third of all annual deaths worldwide. Low- and middle-income countries (LMICs) are disproportionately highly affected covering 80% of these deaths. For CVD, hypertension (HTN) is the leading modifiable risk factor. The comparative impact of diagnostic interventions that improve either the accuracy, the reach, or the completion of HTN screening in comparison to the current standard of care has not been estimated. METHODS AND FINDINGS: This microsimulation study estimated the impact on HTN-induced morbidity and mortality in LMICs for four different scenarios: (S1) lower HTN diagnostic accuracy; (S2) improved HTN diagnostic accuracy; (S3) better implementation strategies to reach more persons with existing tools; and, lastly, (S4) the wider use of easy-to-use tools, such as validated, automated digital blood pressure measurement devices to enhance screening completion, in comparison to the current standard of care (S0). Our hypothetical population was parametrized using nationally representative, individual-level HPACC data and the global burden of disease data. The prevalence of HTN in the population was 31% out of which 60% remained undiagnosed. We investigated how the alteration of a yearly blood pressure screening event impacts morbidity and mortality in the population over a period of 10 years. The study showed that while improving test accuracy avoids 0.6% of HTN-induced deaths over 10 years (13,856,507 [9,382,742; 17,395,833]), almost 40 million (39,650,363 [31,34,233, 49,298,921], i.e., 12.7% [9.9, 15.8]) of the HTN-induced deaths could be prevented by increasing coverage and completion of a screening event in the same time frame. Doubling the coverage only would still prevent 3,304,212 million ([2,274,664; 4,164,180], 12.1% [8.3, 15.2]) CVD events 10 years after the rollout of the program. Our study is limited by the scarce data available on HTN and CVD from LMICs. We had to pool some parameters across stratification groups, and additional information, such as dietary habits, lifestyle choice, or the blood pressure evolution, could not be considered. Nevertheless, the microsimulation enabled us to include substantial heterogeneity and stochasticity toward the different income groups and personal CVD risk scores in the model. CONCLUSIONS: While it is important to consider investing in newer diagnostics for blood pressure testing to continuously improve ease of use and accuracy, more emphasis should be placed on screening completion.


Subject(s)
Hypertension , Humans , Hypertension/diagnosis , Hypertension/epidemiology
18.
Cancer ; 128 Suppl 4: 875-882, 2022 02 15.
Article in English | MEDLINE | ID: mdl-35133661

ABSTRACT

The development and implementation of a multicancer early detection (MCED) test that is effective and affordable has the potential to change cancer care systems around the world. However, careful consideration is needed within the context of different health care settings (both low- and middle-income countries and high-income countries) to roll out an MCED test and promote equity in access.


Subject(s)
Developing Countries , Neoplasms , Early Detection of Cancer , Humans , Income , Internationality , Neoplasms/diagnosis , Neoplasms/therapy
19.
J Infect Dis ; 226(3): 420-430, 2022 08 26.
Article in English | MEDLINE | ID: mdl-32614451

ABSTRACT

BACKGROUND: Hepatitis C virus (HCV) screening is critical to HCV elimination efforts. Simplified diagnostics are required for low-resource settings and difficult-to-reach populations. This retrospective study assessed performance of rapid diagnostic tests (RDTs) for detection of HCV antibodies. METHODS: Two lots of 13 RDTs were evaluated at 3 laboratories using archived plasma samples from 4 countries (Nigeria, Georgia, Cambodia, and Belgium). HCV status was determined using 3 reference tests according to a composite algorithm. Sensitivity and specificity were evaluated in HIV-infected and HIV-uninfected populations. Operational characteristics were also assessed. RESULTS: In total, 1710 samples met inclusion criteria. In HIV-uninfected samples (n = 384), the majority of RDTs had sensitivity ≥98% in 1 or both lots and most RDTs had specificity ≥99%. In HIV-infected samples (n = 264), specificity remained high but sensitivity was markedly lower than in HIV-uninfected samples; only 1 RDT reached >95%. The majority of HIV-infected samples for which sensitivity was low did not have detectable HCV viral load/core antigen. Interreader variability, lot-to-lot variability, and rate of invalid runs were low for all RDTs (<2%). CONCLUSIONS: HCV RDTs should be evaluated in the intended target population, as sensitivity can be impacted by population factors such as HIV status. CLINICAL TRIALS REGISTRATION: NCT04033887.


Subject(s)
HIV Infections , Hepatitis C , Humans , Hepacivirus , Diagnostic Tests, Routine , Laboratories , Retrospective Studies , Hepatitis C/complications , Hepatitis C/diagnosis , Hepatitis C Antibodies , Sensitivity and Specificity , HIV Infections/epidemiology
20.
J Diabetes Sci Technol ; 16(4): 962-970, 2022 07.
Article in English | MEDLINE | ID: mdl-33686875

ABSTRACT

BACKGROUND: Self-management is an important pillar for diabetes control and to achieve it, glucose self-monitoring devices are needed. Currently, there exist several different devices in the market and many others are being developed. However, whether these devices are suitable to be used in resource constrained settings is yet to be evaluated. AIMS: To assess existing glucose monitoring tools and also those in development against the REASSURED which have been previously used to evaluate diagnostic tools for communicable diseases. METHODS: We conducted a scoping review by searching PubMed for peer-review articles published in either English, Spanish or Portuguese in the last 5 years. We selected papers including information about devices used for self-monitoring and tested on humans with diabetes; then, the REASSURED criteria were used to assess them. RESULTS: We found a total of 7 continuous glucose monitoring device groups, 6 non-continuous, and 6 devices in development. Accuracy varied between devices and most of them were either invasive or minimally invasive. Little to no evidence is published around robustness, affordability and delivery to those in need. However, when reviewing publicly available prices, none of the devices would be affordable for people living in low- and middle-income countries. CONCLUSIONS: Available devices cannot be considered adapted for use in self-monitoring in resource constraints settings. Further studies should aim to develop less-invasive devices that do not require a large set of components. Additionally, we suggest some improvement in the REASSURED criteria such as the inclusion of patient-important outcomes to increase its appropriateness to assess non-communicable diseases devices.


Subject(s)
Diabetes Mellitus , Self-Management , Blood Glucose , Blood Glucose Self-Monitoring , Diabetes Mellitus/diagnosis , Diabetes Mellitus/therapy , Humans , Technology