Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1700-1710, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39084744

ABSTRACT

BACKGROUND: Hybrid-convergent radiofrequency (RF) ablation targeting pulmonary veins (PVs) and left atrial posterior wall (LAPW) has shown better arrhythmic outcomes than an endocardial-only RF strategy, despite higher rates of complications. Comparisons with extensive pulsed field ablation (PFA) are currently lacking. OBJECTIVES: This study aimed to compare the efficacy and safety of the hybrid-convergent RF vs PFA of PVs and LAPW in long-standing persistent atrial fibrillation (LSPAF). METHODS: Ninety-three consecutive LSPAF patients, treated with 2-step hybrid-convergent RF ablation (hybrid group, n = 49) or with PFA of PVs and LAPW (PFA group, n = 44) were enrolled. Primary efficacy endpoint was defined as any atrial tachyarrhythmias (ATA) recurrence after the 3-month blanking period, over a follow-up time of 12 months. Periprocedural adverse events and late complications during follow-up were deemed primary safety outcomes. RESULTS: The hybrid and PFA groups had similar baseline characteristics; mean age was hybrid 63.8 ± 10.6 years vs PFA 66.0 ± 7.4 years; P = 0.105. PV and LAPW ablation were acutely successful in all patients. Step 1 hybrid-epicardial procedures were longer than PFA (166 [Q1-Q3: 140-205] minutes vs 107.5 [Q1-Q3: 82.5-12] minutes; P < 0.01). At 12-month follow-up, there was no difference in ATA recurrences between groups (hybrid 36.7% vs PFA 40.9%; P = 0.680; log-rank at survival analysis P = 0.539). After adjusting for confounders, a larger left atrial volume and recurrences during the blanking-period were predictors of ATA recurrences after ablation, regardless of procedural technique employed. PFA showed a better safety profile with a lower rate of major periprocedural complications compared with hybrid ablation (12% vs 0%; P = 0.028). CONCLUSIONS: Hybrid-convergent and PFA share comparable arrhythmic outcomes in LSPAF, but hybrid-convergent ablation carries higher periprocedural risks.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Male , Middle Aged , Female , Aged , Catheter Ablation/methods , Catheter Ablation/adverse effects , Pulmonary Veins/surgery , Treatment Outcome , Recurrence , Heart Atria/surgery , Heart Atria/physiopathology
2.
Article in English | MEDLINE | ID: mdl-37708328

ABSTRACT

Pulmonary vein isolation and left atrial posterior wall ablation using the Farapulse system, followed by left atrial appendage occlusion, have been achieved as single combined procedure to treat long-standing persistent atrial fibrillation in a patient at high hemorrhagic risk.

3.
Front Surg ; 10: 1090565, 2023.
Article in English | MEDLINE | ID: mdl-37304180

ABSTRACT

Autologous vein and artery remains the first choice for vascular grafting procedures in small-diameter vessels such as coronary and lower limb districts. Unfortunately, these vessels are often found to be unsuitable in atherosclerotic patients due to the presence of calcifications or to insufficient size. Synthetic grafts composed of materials such as expanded polytetrafluoroethylene (ePTFE) are frequently employed as second choice, because of their widespread availability and success in the reconstruction of larger arteries. However, ePTFE grafts with small diameter are plagued by poor patency rates due to surface thrombogenicity and intimal hyperplasia, caused by the bioinertness of the synthetic material and aggravated by low flow conditions. Several bioresorbable and biodegradable polymers have been developed and tested to exploit such issues for their potential stimulation to endothelialization and cell infiltration. Among these, silk fibroin (SF) has shown promising pre-clinical results as material for small-diameter vascular grafts (SDVGs) because of its favorable mechanical and biological properties. A putative advantage in graft infection in comparison with synthetic materials is plausible, although it remains to be demonstrated. Our literature review will focus on the performance of SF-SDVGs in vivo, as evaluated by studies performing vascular anastomosis and interposition procedures, within small and large animal models and different arterial districts. Efficiency under conditions that more accurately mime the human body will provide encouraging evidence towards future clinical applications.

4.
ESC Heart Fail ; 10(1): 709-715, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36259268

ABSTRACT

Eosinophilic granulomatosis with polyangiitis (EGPA) is a rare multisystem disorder; cardiac involvement may include eosinophilic myocarditis. A 67-year-old woman presented with 1-week history of dyspnoea and orthopnoea. She had a history of adult-onset asthma and peripheral eosinophilia. The investigations showed T-wave inversion on lateral leads, peripheral eosinophilia, elevated troponin and BNP values, and severe biventricular systolic dysfunction with diffuse hypokinesia and apical akinesia. Computed tomography excluded coronary disease and showed bilateral basal ground-glass opacities, air-space consolidation, and bilateral reticular-nodular pattern. Cardiac magnetic resonance findings were compatible with active myocardial inflammation. An endomyocardial biopsy (EMB) confirmed the diagnosis of eosinophilic myocarditis, and a therapy with oral corticosteroids and heart failure medications was started.


Subject(s)
Churg-Strauss Syndrome , Eosinophilia , Granulomatosis with Polyangiitis , Heart Failure , Myocarditis , Aged , Female , Humans , Churg-Strauss Syndrome/diagnosis , Churg-Strauss Syndrome/drug therapy , Eosinophilia/diagnosis , Granulomatosis with Polyangiitis/diagnosis , Granulomatosis with Polyangiitis/drug therapy , Myocarditis/diagnosis
5.
Int J Cardiovasc Imaging ; 38(2): 397-405, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34546457

ABSTRACT

Cardiac magnetic resonance (CMR) findings suggesting a suspected left-dominant arrhythmogenic cardiomyopathy (LDAC) may be difficult to distinguish from those related to previous myocarditis; however, especially in patients with ventricular arrhythmias (VA) with ECG morphology consistent with a left ventricle (LV) origin differential diagnosis is fundamental. Aim of the study was to identify potential imaging features at CMR specific for LDAC diagnosis. Between January 2011 and December 2019, we enrolled 15 consecutive stable patients with a recent diagnosis of significant VA and ECG morphology consistent with a LV origin, detection of potential LV arrhythmic substrate at CMR and undergoing a clinically-indicated LV endomyocardial biopsy showing tissue abnormalities consistent with the diagnosis of LDAC. From the same CMR-endomyocardial biopsy registry, a second group of 30 consecutive patients who underwent CMR and biopsy with a histological diagnosis of previous myocarditis were identified. (1) Subepicardial LGE at the level of the posterolateral wall of the LV was detected in 13 cases of LDAC vs. 21 cases of myocarditis; (2) fat infiltration, and particularly subepicardial posterolateral fat infiltration, was found in almost all LDAC patients vs. one myocarditis only (p < 0.01). (3) No differences in other CMR findings or in any clinical or echocardiographic parameters were found between patients with a biopsy consistent with LDAC vs. myocarditis. In patients with significant VA and ECG morphology consistent with a LV origin, the presence of morpho-functional involvement of the subepicardial layer of LV posterolateral wall at CMR (LGE, fat infiltration, wall dyskinesis) supports LDAC diagnosis.


Subject(s)
Myocarditis , Diagnosis, Differential , Humans , Magnetic Resonance Imaging , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Myocarditis/diagnostic imaging , Predictive Value of Tests
6.
JACC Clin Electrophysiol ; 7(9): 1108-1117, 2021 09.
Article in English | MEDLINE | ID: mdl-33933407

ABSTRACT

OBJECTIVES: This study aimed to assess the long-term outcomes of minimally fluoroscopic approach (MFA) compared with conventional fluoroscopic ablation (ConvA) in terms of recurrences of arrhythmia and long-term complications. BACKGROUND: Catheter ablation (CA) of supraventricular tachycardia (SVT) with an MFA, under the guidance of electroanatomic mapping (EAM) systems, results in a significant reduction in exposure to ionizing radiations without impairing acute procedural success and complication rate. However, data regarding long-term outcomes of MFA compared with ConvA are lacking. METHODS: This is a retrospective observational study. All patients undergoing MFA CA of SVT (atrioventricular nodal re-entrant tachycardia and atrioventricular re-entrant tachycardia) between 2010 and 2015 were enrolled and were compared with matched subjects (1 MFA: 2 ConvA) undergoing ConvA during the same period. The 2 co-primary outcomes were recurrence of arrhythmias and long-term complications. RESULTS: A total of 618 patients (mean age 38 ± 15 years, 60% female) were enrolled. MFA included 206 patients, whereas 412 were treated with ConvA. Acute success (99% vs. 97%; p = 0.10) and acute complications (2.4% vs. 5.3%; p = 0.14) were similar in the 2 groups. During a median follow-up of 4.4 years, 5.9% of patients experienced recurrence of arrhythmias. At multivariate analysis, ConvA (hazard ratio [HR]: 3.03) and procedural success (HR: 0.10) were independently associated with recurrence of arrhythmias. Late complications (i.e., advance atrioventricular block and need for pacemaker implantation) occurred more frequently in ConvA (3.4% vs. 0.5%; p = 0.03) compared with MFA. CONCLUSIONS: CA guided by EAM systems with MFA provided better long-term results and reduced risk of complications compared with ConvA.


Subject(s)
Catheter Ablation , Tachycardia, Supraventricular , Tachycardia, Ventricular , Adult , Female , Fluoroscopy , Humans , Male , Middle Aged , Tachycardia, Supraventricular/surgery , Treatment Outcome , Young Adult
7.
Int J Mol Sci ; 22(5)2021 Mar 06.
Article in English | MEDLINE | ID: mdl-33800912

ABSTRACT

Arrhythmogenic Cardiomyopathy (ACM) is characterized by the replacement of the myocardium with fibrotic or fibro-fatty tissue and inflammatory infiltrates in the heart. To date, while ACM adipogenesis is a well-investigated differentiation program, ACM-related fibrosis remains a scientific gap of knowledge. In this study, we analyze the fibrotic process occurring during ACM pathogenesis focusing on the role of cardiac mesenchymal stromal cells (C-MSC) as a source of myofibroblasts. We performed the ex vivo studies on plasma and right ventricular endomyocardial bioptic samples collected from ACM patients and healthy control donors (HC). In vitro studies were performed on C-MSC isolated from endomyocardial biopsies of both groups. Our results revealed that circulating TGF-ß1 levels are significantly higher in the ACM cohort than in HC. Accordingly, fibrotic markers are increased in ACM patient-derived cardiac biopsies compared to HC ones. This difference is not evident in isolated C-MSC. Nevertheless, ACM C-MSC are more responsive than HC ones to TGF-ß1 treatment, in terms of pro-fibrotic differentiation and higher activation of the SMAD2/3 signaling pathway. These results provide the novel evidence that C-MSC are a source of myofibroblasts and participate in ACM fibrotic remodeling, being highly responsive to ACM-characteristic excess TGF-ß1.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia/physiopathology , Endocardium/pathology , Mesenchymal Stem Cells/pathology , Myofibroblasts/pathology , Transforming Growth Factor beta1/physiology , Adult , Arrhythmogenic Right Ventricular Dysplasia/blood , Arrhythmogenic Right Ventricular Dysplasia/pathology , Cell Differentiation , Endocardium/metabolism , Female , Fibrosis , Humans , Male , Mesenchymal Stem Cells/metabolism , Middle Aged , RNA, Messenger/biosynthesis , Signal Transduction/physiology , Smad2 Protein/physiology , Smad3 Protein/physiology , Transforming Growth Factor beta1/blood
8.
Medicina (Kaunas) ; 57(2)2021 Feb 14.
Article in English | MEDLINE | ID: mdl-33673000

ABSTRACT

Sudden cardiac death in athletes is a relatively rare event, but due to the increasing number of individuals practicing high-performance sports, in absolute terms, it has become an important issue to be addressed. Since etiologies are many and the occurrence is rare, tracing the ideal preparticipation screening program is challenging. So far, as screening tools, a comprehensive clinical evaluation and a simple 12-lead electrocardiogram (ECG) seem to be the most cost-effective strategy. Recent technological advances came to significantly help as second-line investigation tools, especially the cardiac magnetic resonance, which allows for a more detailed ventricular evaluation, cardiac tissue characterization, and eliminates the poor acoustic window problem. This article aims to review all aspects related to sudden cardiac death in athletes, beginning with definitions and epidemiology, passing through etiology and clinical characteristics, then finishing with a discussion about the best ambulatory investigational approach.


Subject(s)
Athletes , Death, Sudden, Cardiac , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Electrocardiography , Humans , Mass Screening
9.
J Cardiovasc Electrophysiol ; 32(3): 588-594, 2021 03.
Article in English | MEDLINE | ID: mdl-33537996

ABSTRACT

INTRODUCTION: Catheter ablation is superior to drugs regarding atrial fibrillation (AF) recurrence, symptoms improvement, and mortality reduction in heart failure. POLARx™ is a novel cryoballoon, with technical improvements seeking to improve outcomes. So far, its clinical evidence is restricted to a case report. METHODS: To compare the POLARx™ cryoballoon procedural safety and efficacy to the already established Arctic Front Advance PRO™ (AFAP) in a single-center cohort study, consecutive patients undergoing AF cryoablation with the POLARx™ were enrolled. Data were prospectively gathered. POLARx™ patients were compared with a historical cohort of patients submitted to AF cryoablation with the AFAP. RESULTS: Seventy patients were analyzed, 20 in POLARx™, and 50 in the AFAP group. They all underwent first-time pulmonary vein isolation, 77% were male, 94% had paroxysmal AF, median age was 62.5 years, median CHA2 DS2 -VASc 1, left-atrium size 34 ml/m², and 65% were receiving anticoagulation. The primary end-point, all pulmonary veins isolation, was 100% in both groups. The complication rate was similar (0% POLARx™ vs. 5.7% AFAP, p = .39). The median total procedural time was longer in the POLARx™ group (90 min vs. 60 min, p < .001), but the overall time-to-isolation (TTI; 44.8 s vs. 39 s, p = .253) and ablation time (15 min vs. 13.7 min, p = .122) was similar between POLARx™ and AFAP groups, respectively. Despite equal TTI, the POLARx™ had a lower minimal temperature reached (-57°C vs -47°C, p < .001). CONCLUSION: The novel POLARx™ cryoballoon had similar efficacy and safety compared with the AFAP. It was also associated with longer procedural times, similar TTI, and lower minimum temperature reached.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Cohort Studies , Cryosurgery/adverse effects , Humans , Male , Middle Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Technology , Treatment Outcome
10.
Circ Arrhythm Electrophysiol ; 13(12): e009005, 2020 12.
Article in English | MEDLINE | ID: mdl-33197325

ABSTRACT

BACKGROUND: Arrhythmogenic left ventricular cardiomyopathy (ALVC) is an under-characterized phenotype of arrhythmogenic cardiomyopathy involving the LV ab initio. ALVC was not included in the 2010 International Task Force Criteria for arrhythmogenic right ventricular cardiomyopathy diagnosis and data regarding this phenotype are scarce. METHODS: Clinical characteristics were reported from all consecutive patients diagnosed with ALVC, defined as a LV isolated late gadolinium enhancement and fibro-fatty replacement at cardiac magnetic resonance plus genetic variants associated with arrhythmogenic right ventricular cardiomyopathy and of an endomyocardial biopsy showing fibro-fatty replacement complying with the 2010 International Task Force Criteria in the LV. RESULTS: Twenty-five patients ALVC (53 [48-59] years, 60% male) were enrolled. T wave inversion in infero-lateral and left precordial leads were the most common ECG abnormalities. Overall arrhythmic burden at study inclusion was 56%. Cardiac magnetic resonance showed LV late gadolinium enhancement in the LV lateral and posterior basal segments in all patients. In 72% of the patients an invasive evaluation was performed, in which electroanatomical voltage mapping and electroanatomical voltage mapping-guided endomyocardial biopsy showed low endocardial voltages and fibro-fatty replacement in areas of late gadolinium enhancement presence. Genetic variants in desmosomal genes (desmoplakin and desmoglein-2) were identified in 12/25 of the cohort presenting pathogenic/likely pathogenic variants. A definite/borderline 2010 International Task Force Criteria arrhythmogenic right ventricular cardiomyopathy diagnosis was reached only in 11/25 patients. CONCLUSIONS: ALVC presents with a preferential involvement of the lateral and postero-lateral basal LV and is associated mostly with variants in desmoplakin and desmoglein-2 genes. An amendment to the current International Task Force Criteria is reasonable to better diagnose patients with ALVC.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia/diagnosis , Desmoglein 2/genetics , Desmoplakins/genetics , Genetic Variation , Heart Rate , Myocardium/pathology , Arrhythmogenic Right Ventricular Dysplasia/genetics , Arrhythmogenic Right Ventricular Dysplasia/pathology , Arrhythmogenic Right Ventricular Dysplasia/physiopathology , Biopsy , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Genetic Predisposition to Disease , Genetic Testing , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Phenotype , Predictive Value of Tests , Registries
11.
Circulation ; 142(13): 1249-1260, 2020 09 29.
Article in English | MEDLINE | ID: mdl-32791857

ABSTRACT

BACKGROUND: Electroanatomic voltage mapping (EVM) is a promising modality for guiding endomyocardial biopsies (EMBs). However, few data support its feasibility and safety. We now report the largest cohort of patients undergoing EVM-guided EMBs to show its diagnostic yield and to compare it with a cardiac magnetic resonance (CMR)-guided approach. METHODS: We included 162 consecutive patients undergoing EMB at our institution from 2010 to 2019. EMB was performed in pathological areas identified at EVM and CMR. CMR and EVM sensitivity and specificity regarding the identification of pathological substrates of myocardium were evaluated according to EMB results. RESULTS: Preoperative CMR showed late gadolinium enhancement in 70% of the patients, whereas EVM identified areas of low voltage in 61%. Right (73%), left (19%), or both ventricles (8%) underwent sampling. EVM proved to have sensitivity similar to CMR (74% versus 77%), with specificity being 70% and 47%, respectively. In 12 patients with EMB-proven cardiomyopathy, EVM identified pathological areas that had been undetected at CMR evaluation. Sensitivity of pooled EVM and CMR was as high as 95%. EMB analysis allowed us to reach a new diagnosis, different from the suspected clinical diagnosis, in 39% of patients. The complications rate was low, mostly related to vascular access, with no patients requiring urgent management. CONCLUSIONS: EVM proved to be a promising tool for targeted EMB because of its sensitivity and specificity for identification of myocardial pathological substrates. EVM was demonstrated to have accuracy similar to CMR. EVM and CMR together conferred a positive predictive value of 89% on EMB.


Subject(s)
Contrast Media/administration & dosage , Electrophysiologic Techniques, Cardiac , Gadolinium/administration & dosage , Heart Ventricles , Magnetic Resonance Imaging , Myocardium , Adult , Biopsy , Female , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Male , Middle Aged
12.
Heart Rhythm ; 17(8): 1251-1259, 2020 08.
Article in English | MEDLINE | ID: mdl-32200046

ABSTRACT

BACKGROUND: Disease progression and ventricular arrhythmias (VAs) in arrhythmogenic right ventricular cardiomyopathy (ARVC) are correlated with physical exercise, and clinical detraining and avoidance of competitive sport practice are suggested for ARVC patients. An algorithm assessing primary arrhythmic risk in ARVC patients was recently developed by Cadrin-Tourigny et al. Data regarding its transferability to athletes are lacking. OBJECTIVE: The purpose of this study was to assess the reliability of the Cadrin-Tourigny risk prediction algorithm in a cohort of athletes with ARVC and to describe the impact of clinical detraining on disease progression. METHODS: All athletes undergoing clinical detraining after ARVC diagnosis at our institution were enrolled. Baseline and follow-up clinical characteristics and data on VA events occurring during follow-up were collected. The Cadrin-Tourigny algorithm was used to calculate the a priori predicted VA risk, which was compared with the observed outcomes. RESULTS: Twenty-five athletes (age 36.1 ± 14.0 years; 80% male) with definite ARVC who were undergoing clinical detraining were enrolled. Over median (interquartile range) follow-up of 5.3 (3.2-6.6) years, a reduction in premature ventricular complex (PVC) burden (P = .001) was assessed, and 10 VA events (40%) were recorded. The a priori algorithm-predicted risk seemed to fit with the observed cohort arrhythmic risk [mean observed-predicted risk difference over 5 years -0.85% (interquartile range -4.8% to +3.1%); P = .85]. At 1-year follow-up, 11 patients (44%) had an improved stress ECG response, and no significant changes in right ventricular ejection fraction were observed. CONCLUSION: Clinical detraining is associated with PVC burden reduction in athletes with ARVC. The novel risk prediction algorithm does not seem to require any correction for its application to ARVC athletes.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia/physiopathology , Athletes , Electrocardiography , Exercise/physiology , Stroke Volume/physiology , Ventricular Function, Right/physiology , Aged , Female , Humans , Male , Reproducibility of Results
13.
J Interv Card Electrophysiol ; 55(1): 27-34, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30515625

ABSTRACT

PURPOSE: Previous studies indicate force time integral (FTI) as a radiofrequency (RF) lesion quality marker, while not considering power supply. Tacticath™ Quartz catheter provides Lesion index (LSI), a lesion quality marker derived by contact force (CF), power supply, and RF time combined. Our aim is to assess LSI and FTI correlation and a LSI-related cutoff of atrial fibrillation (AF) recurrences 12 months after pulmonary vein isolation (PVI). METHODS: We retrospectively enrolled 37 patients who underwent RF ablation using Tacticath™ Quartz catheter. AF recurrence rate was evaluated 3, 6, and 12 months after PVI procedure. RESULTS: AF recurrence was detected in 32% of patients. FTI mean value was significantly lower in left superior pulmonary vein (LSPV: 256 ± 86 gs vs 329 ± 117 gs, p = 0.05) and right inferior pulmonary vein (RIPV: 253 ± 128 gs vs 394 ± 123 gs p = 0.006) in patients with AF recurrences; no significant differences were found in right superior pulmonary vein (RSPV) and left inferior pulmonary vein (LIPV). LSI instead was significantly higher for all veins in patients without AF recurrences: LSPV (5.2 ± 0.7 vs 4.6 ± 0.8, p = 0.03), LIPV (5.0 ± 0.8 vs 4.5 ± 0.6, p = 0.04), RSPV (5.5 ± 0.6 vs 5.1 ± 0.6, p = 0.05), and RIPV (5.5 ± 0.7 vs 4.7 ± 0.8, p = 0.006). Receiver operator characteristic curve suggests 5.3 as LSI overall cutoff value predicting freedom from disease at 1-year follow-up. CONCLUSIONS: Our preliminary data suggest that a LSI mean value higher than 5.3 can be considered a good predictor of AF freedom at 1-year follow-up.


Subject(s)
Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Radiofrequency Ablation/instrumentation , Echocardiography , Electrocardiography , Epicardial Mapping , Female , Humans , Male , Middle Aged , Recurrence , Retrospective Studies
14.
J Am Heart Assoc ; 7(11)2018 05 22.
Article in English | MEDLINE | ID: mdl-29789334

ABSTRACT

BACKGROUND: Only a few studies have systematically evaluated fluoroscopy data of electrophysiological and device implantation procedures. Aims of this study were to quantify ionizing radiation exposure for electrophysiological/device implantation procedures in a large series of patients and to analyze the x-ray exposure trend over years and radiation exposure in patients undergoing atrial fibrillation ablation considering different technical aspects. METHODS AND RESULTS: We performed a retrospective analysis of all electrophysiological/device implantation procedures performed during the past 7 years in a modern, large-volume laboratory. We reported complete fluoroscopy data on 8150 electrophysiological/device implantation procedures (6095 electrophysiological and 2055 device implantation procedures); for each type of procedure, effective dose and lifetime attributable risk of cancer incidence and mortality were calculated. Over the 7-year period, we observed a significant trend reduction in fluoroscopy time, dose area product, and effective dose for all electrophysiological procedures (P<0.001) and a not statistically significant trend reduction for device implantation procedures. Analyzing 2416 atrial fibrillation ablations, we observed a significant variability of fluoroscopy time, dose area product and effective dose among 7 different experienced operators (P<0.0001) and a significant reduction of fluoroscopy use over time (P<0.0001) for all of them. Considering atrial fibrillation ablation techniques, fluoroscopy time was not different (P = 0.74) for radiofrequency catheter ablation in comparison with cryoablation, though cryoablation was still associated with higher dose area product and effective dose values (P<0.001). CONCLUSIONS: Electrophysiological procedures involve a nonnegligible x-ray use, leading to an increased risk of malignancy. Awareness of radiation-related risk, together with technological advances, can successfully optimize fluoroscopy use.


Subject(s)
Arrhythmias, Cardiac/therapy , Cardiac Catheterization , Occupational Exposure , Radiation Dosage , Radiation Exposure , Radiography, Interventional , Aged , Arrhythmias, Cardiac/diagnosis , Cardiac Catheterization/adverse effects , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Electrophysiologic Techniques, Cardiac/adverse effects , Female , Fluoroscopy/adverse effects , Humans , Male , Middle Aged , Occupational Exposure/adverse effects , Occupational Health , Operative Time , Prosthesis Implantation/adverse effects , Radiation Exposure/adverse effects , Radiography, Interventional/adverse effects , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors
15.
BMC Cardiovasc Disord ; 18(1): 15, 2018 01 30.
Article in English | MEDLINE | ID: mdl-29382308

ABSTRACT

BACKGROUND: Based on a plenty of different applications, intracardiac echocardiography (ICE) is now a well-established technology in complex electrophysiological procedures. Recently, ICE has become the most widely used ultrasound-based imaging tool to guide diagnostic endomyocardial biopsy (EMB). EMB of cardiac mass guided by ICE is an interesting application of ICE. Allowing a correct positioning of the bioptome, ICE reduce the procedure-related risks and the need of a diagnostic open-chest procedure reserving the more invasive approach to selected cases. CASE PRESENTATION: Hereby we report a case series of right ventricular masses in which the EMB was safely and effectively performed under ICE guidance giving essential information for planning the therapeutic strategy. CONCLUSIONS: The diagnosis of both metastatic and primary cardiac tumors relies on the histopathological analyses. The endomyocardial biopsy is a valuable tool for preoperative diagnosis and surgical planning of intracardiac masses suspected for tumors. In our experience, the use of ICE for right ventricle EMB of an intracardiac mass is an attractive modality thanks to the precise localization of the cardiac structures and the ability to guide bioptic withdrawal in the target area.


Subject(s)
Echocardiography , Heart Neoplasms/pathology , Image-Guided Biopsy/methods , Myocardium/pathology , Aged , Female , Heart Neoplasms/diagnostic imaging , Heart Neoplasms/secondary , Heart Neoplasms/therapy , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Predictive Value of Tests , Prognosis
16.
Minerva Cardioangiol ; 66(1): 49-62, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28862408

ABSTRACT

Electrophysiology procedures are traditionally performed under fluoroscopic guidance. Nowadays a growing interest in the radiation risk associated to these procedures has been cultivated, since radiation exposure has non-negligible stochastic and deterministic effects on health. A correlation between radiation exposure and lifetime malignancy effect is difficult to establish and the threshold of a completely safe exposure dose is unknown. Thus, electrophisiologists have become aware of the use of fluoroscopy and they have tried to use all the complementary imaging technologies available in order to reduce the radiological exposure. This review is aimed at evaluating the radiation exposure risk, both for the patients and the operators. We describe electroanatomical mapping systems and technologies, which allow the reduction of radiation exposure. We review the main literature based on different catheter ablation procedures with the use of the abovementioned technologies, specifically focusing on feasibility, safety, and radiation exposure. Finally, we highlight the necessity of increasing the radiological risk awareness among operators and cardiological scientific societies.


Subject(s)
Arrhythmias, Cardiac/surgery , Catheter Ablation/methods , Fluoroscopy/methods , Arrhythmias, Cardiac/diagnostic imaging , Fluoroscopy/adverse effects , Humans , Radiation Dosage , Radiation Exposure , Radiography/adverse effects , Radiography/methods
17.
Clin Case Rep ; 5(9): 1459-1461, 2017 09.
Article in English | MEDLINE | ID: mdl-28878903

ABSTRACT

Transvenous extraction of Riata lead could be a challenging procedure due to insulation failure and conductor cables' externalization through the eroded outer insulation. In this case, a complete lead extraction was achieved through a combined LASER and femoral approach because of the massive conductors' externalization.

18.
Expert Rev Med Devices ; 14(8): 609-619, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28678556

ABSTRACT

INTRODUCTION: During the past years, endomyocardial biopsy (EMB) has gradually spread into clinical practice. However, the role of EMB in the diagnosis and treatment of cardiovascular diseases remains a controversial issue, especially in the setting of unexplained ventricular arrhythmias. Areas covered: This review describes the methodology of EMB guided by combined use of three-dimensional electroanatomical mapping systems and intracardiac echo and summarizes the classical, fluoroscopy-guided EMB technique. Finally, the personal experience acquired with the 'electrophysiologist-made' integration methodology has been reported. Expert commentary: Since EMB has been considered in the setting of arrhythmogenic cardiomyopathy, myocarditis, cardiac sarcoidosis, drug toxicity, and/or other diseases causing malignant ventricular arrhythmias, the electrophysiologists have started to perform firsthand biopsy. The electrophysiologists introduced the use of electroanatomical mapping systems and intracardiac echo. This new methodology improved significantly biopsy diagnostic yield and allowed to reduce complications.


Subject(s)
Cardiomyopathies/pathology , Image-Guided Biopsy/instrumentation , Myocardium/pathology , Sarcoidosis/pathology , Arrhythmias, Cardiac/etiology , Cardiomyopathies/complications , Humans , Image-Guided Biopsy/methods , Myocarditis/pathology
19.
Sci Rep ; 7(1): 4802, 2017 07 06.
Article in English | MEDLINE | ID: mdl-28684747

ABSTRACT

Diagnosis of Arrhythmogenic CardioMyopathy (ACM) is challenging and often late after disease onset. No circulating biomarkers are available to date. Given their involvement in several cardiovascular diseases, plasma microRNAs warranted investigation as potential non-invasive diagnostic tools in ACM. We sought to identify circulating microRNAs differentially expressed in ACM with respect to Healthy Controls (HC) and Idiopathic Ventricular Tachycardia patients (IVT), often in differential diagnosis. ACM and HC subjects were screened for plasmatic expression of 377 microRNAs and validation was performed in 36 ACM, 53 HC, 21 IVT. Variable importance in data partition was estimated through Random Forest analysis and accuracy by Receiver Operating Curves. Plasmatic miR-320a showed 0.53 ± 0.04 fold expression difference in ACM vs. HC (p < 0.01). A similar trend was observed when comparing ACM (n = 13) and HC (n = 17) with athletic lifestyle, a ACM precipitating factor. Importantly, ACM patients miR-320a showed 0.78 ± 0.05 fold expression change vs. IVT (p = 0.03). When compared to non-invasive ACM diagnostic parameters, miR-320a ranked highly in discriminating ACM vs. IVT and it increased their accuracy. Finally, miR-320a expression did not correlate with ACM severity. Our data suggest that miR-320a may be considered a novel potential biomarker of ACM, specifically useful in ACM vs. IVT differentiation.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia/diagnosis , MicroRNAs/genetics , Tachycardia, Ventricular/diagnosis , Adult , Arrhythmogenic Right Ventricular Dysplasia/blood , Arrhythmogenic Right Ventricular Dysplasia/genetics , Arrhythmogenic Right Ventricular Dysplasia/physiopathology , Biomarkers/blood , Case-Control Studies , Diagnosis, Differential , Female , Humans , Male , MicroRNAs/blood , Middle Aged , ROC Curve , Severity of Illness Index , Tachycardia, Ventricular/blood , Tachycardia, Ventricular/genetics , Tachycardia, Ventricular/physiopathology
20.
Cardiol Clin ; 33(3): 423-32, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26115828

ABSTRACT

Clinical evaluation of syncope in the athlete remains a challenge. Although benign mechanisms predominate, syncope may be arrhythmic and precede SCD. Exercise-induced syncope should be regarded as an important alarming symptom of an underlying cardiac disease predisposing to arrhythmic cardiac arrest. All athletes with syncope require a focused and detailed workup for underlying cardiac causes, either structural or electrical. Major aim is to identify athletes at risk and to protect them from SCD. Athletes with potentially life-threatening etiologies of syncope should be restricted from competitive sports.


Subject(s)
Athletes , Death, Sudden, Cardiac/etiology , Electrocardiography , Heart Rate/physiology , Syncope , Humans , Syncope/complications , Syncope/diagnosis , Syncope/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...