Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Nephrol ; 8: 2, 2007 Jan 15.
Article in English | MEDLINE | ID: mdl-17224056

ABSTRACT

BACKGROUND: The prevalences and risk factors of microalbuminuria are not full described among black African diabetic patients. This study aimed at determining the prevalence of microalbuminuria among African diabetes patients in Dar es Salaam, Tanzania, and relate to socio-demographic features as well as clinical parameters. METHODS: Cross sectional study on 91 Type 1 and 153 Type 2 diabetic patients. Two overnight urine samples per patient were analysed. Albumin concentration was measured by an automated immunoturbidity assay. Average albumin excretion rate (AER) was used and were categorised as normalbuminuria (AER < 20 ug/min), microalbuminuria (AER 20-200 ug/min), and macroalbuminuria (AER > 200 ug/min). Information obtained also included age, diabetes duration, sex, body mass index, blood pressure, serum total cholesterol, high-density and low-density lipoprotein cholesterol, triglycerides, serum creatinine, and glycated hemoglobin A1c. RESULTS: Overall prevalence of microalbuminuria was 10.7% and macroalbuminuria 4.9%. In Type 1 patients microalbuminuria was 12% and macroalbuminuria 1%. Among Type 2 patients, 9.8% had microalbuminuria, and 7.2% had macroalbuminuria. Type 2 patients with abnormal albumin excretion rate had significantly longer diabetes duration 7.5 (0.2-24 yrs) than those with normal albumin excretion rate 3 (0-25 yrs), p < 0.001. Systolic and diastolic blood pressure among Type 2 patients with abnormal albumin excretion rate were significantly higher than in those with normal albumin excretion rate, (p < 0.001). No significant differences in body mass index, glycaemic control, and cholesterol levels was found among patients with normal compared with those with elevated albumin excretion rate either in Type 1 or Type 2 patients. A stepwise multiple linear regression analysis among Type 2 patients, revealed AER (natural log AER) as the dependent variable to be predicted by [odds ratio (95% confidence interval)] diabetes duration 0.090 (0.049, 0.131), p < 0.0001, systolic blood pressure 0.012 (0.003-0.021), p < 0.010 and serum creatinine 0.021 (0.012, 0.030). CONCLUSION: The prevalence of micro and macroalbuminuria is higher among African Type 1 patients with relatively short diabetes duration compared with prevalences among Caucasians. In Type 2 patients, the prevalence is in accordance with findings in Caucasians. The present study detects, however, a much lower prevalence than previously demonstrated in studies from sub-Saharan Africa. Abnormal AER was significantly related to diabetes duration and systolic blood pressure.


Subject(s)
Albuminuria/epidemiology , Black People/statistics & numerical data , Diabetes Mellitus, Type 1/epidemiology , Diabetes Mellitus, Type 2/epidemiology , Adolescent , Adult , Age Distribution , Albuminuria/diagnosis , Comorbidity , Confidence Intervals , Cross-Sectional Studies , Developing Countries , Diabetes Mellitus, Type 1/urine , Diabetes Mellitus, Type 2/urine , Female , Humans , Kidney Function Tests , Linear Models , Male , Middle Aged , Prevalence , Radioimmunoassay , Severity of Illness Index , Sex Distribution , Tanzania/epidemiology , Urinalysis
2.
Scand J Gastroenterol ; 41(4): 481-7, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16635918

ABSTRACT

OBJECTIVE: The burden on colonoscopy capacity is considerable and expected to increase further as colorectal cancer screening programmes gain a foothold in Europe. In this situation, it is particularly important to evaluate the quality of the service given. In this article we present our first year of experience with a quality network of endoscopy centres in Norway (Gastronet). MATERIAL AND METHODS: A questionnaire focusing on caecal intubation rate and pain was completed by the endoscopist (on site) and patient (on the day after the examination). Fourteen centres participated with registration of 7370 colonoscopies by 73 endoscopists. RESULTS: There was 100% endoscopist participation, 87% coverage of colonoscopies and an estimated 76% questionnaire coverage of the patient population. Overall caecal intubation rate was 91%, range 83% to 97% between centres (p < 0.001). Patients reporting severe pain during colonoscopy differed from 2 to 24% between centres (p < 0.001). Variations could only partly be explained by differences in procedure practice (sedation, CO2 insufflation). For individual endoscopists, improvement after feedback on performance was restricted to the group of endoscopists having contributed with only 50-99 registered colonoscopies. CONCLUSIONS: In quality assurance programmes we recommend a limited number of variables for registration in order to secure high compliance by endoscopists and patients. One year of experience with Gastronet disclosed a satisfactory overall caecal intubation rate, but considerable variation between centres in practice and ability to offer painless colonoscopy. This suggests a need for formal, centralized training of colonoscopists or the development of quality standards for colonoscopy training and practice.


Subject(s)
Colonoscopy/standards , Cecum/pathology , Colonoscopy/methods , Humans , Norway , Patient Satisfaction , Quality Assurance, Health Care , Quality of Health Care/standards , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL
...