Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Acta Paediatr ; 110(2): 652-658, 2021 02.
Article in English | MEDLINE | ID: mdl-32570288

ABSTRACT

AIM: To evaluate whether renal length z-scores predict renal dysfunction in children with a solitary functioning kidney (SFK). METHODS: In a single-centre retrospective cohort of children with SFK, we correlated body mass index z-scores, extracellular volume and lean body mass to renal length z-scores. We grouped these z-scores to other markers of renal dysfunction (proteinuria, hypertension, extracellular volume and abnormal estimated glomerular function rate [eGFR]) and analysed renal length z-score with multivariate analysis, receiver-operated characteristics (ROC) plots and Youden's index to determine an appropriate cut-off. RESULTS: 111 children had a median follow-up 5.08 years, eGFR 80.8 mL/min/1.73 m2 , and age at last follow-up 7.4 (3.8-13.4 years). The median renal length z-scores of those without any renal dysfunction (n = 37, 25.1%) were greater (+3.66, interquartile range 3.02-4.47) than those with renal dysfunction (median 3.11, interquartile range 1.76-4.11, P = .0107, Mann-Whitney test). Using a cut-off of z-score of >+1.911, the odds ratio for having no renal dysfunction was 0.07 (95% CI 0.002-0.459, P = .0010). However, accuracy of the renal length z-score was poor (ROC curve 0.6488). CONCLUSION: In this cohort of children with SKF, using the renal length z-score as a biomarker of renal dysfunction at 7 years of age is not recommended.


Subject(s)
Solitary Kidney , Child , Glomerular Filtration Rate , Humans , Kidney/diagnostic imaging , Proteinuria , Retrospective Studies , Solitary Kidney/diagnostic imaging
2.
J Innov Card Rhythm Manag ; 10(12): 3924-3928, 2019 Dec.
Article in English | MEDLINE | ID: mdl-32477714

ABSTRACT

Atrioventricular node (AVN) ablation is a strategy to manage patients with drug-refractory atrial fibrillation (AF) and heart failure in whom cardiac resynchronization therapy (CRT) device implantation has been prescribed. This study describes a practical method to perform these two procedures using the same surgical site. Twenty-seven patients were indicated for AVN ablation and concurrent CRT device implantation while presenting with AF and rapid ventricular response (RVR) refractory to medical therapy. After placement of the right and left ventricular leads, a third puncture was made in the axillary vein to obtain access to perform the ablation. After hand-injecting contrast media through a RAMP™ (Abbott Laboratories, Chicago, IL, USA) sheath positioned in the right atrial cavity, the anatomical area corresponding to the AVN was identified using fluoroscopy cine runs obtained in the right anterior oblique and left anterior oblique projections. The adequate site for ablation was confirmed by the bipolar recording of a His-bundle deflection at the tip of the ablation catheter. Radiofrequency energy was delivered to achieve complete heart block. Subsequently, device implant was completed. The method was successfully applied in 27 consecutive cases, achieving permanent complete heart block in all patients. The mean radiofrequency time to achieve heart block was 110 seconds ± 43 seconds. The average procedural time including AVN ablation and device implant was 87 minutes ± 21 minutes. The images obtained with the hand-injected contrast media provided adequate information to readily identify the anatomical area corresponding to the AVN with 100% accuracy. This study suggests that ablation of the AVN can be safely and effectively accomplished via a superior approach in patients undergoing a CRT device implant.

SELECTION OF CITATIONS
SEARCH DETAIL
...