ABSTRACT
The recovery of copper, nickel, zinc, silicon, iron, aluminum, tin and fluoride ions from fluoride leach liquors of non-ground printed circuit boards (PCBs) from mobile phones is described in detail. These PCBs were leached with HFâ¯+â¯H2O2 mixtures after previous treatment with 6â¯molâ¯L-1 NaOH (removal of the solder mask). A combination of solvent extraction (SX) and precipitation techniques was used. 99.5â¯wt% zinc, copper and nickel, in this order, were extracted in one stage (Zn, Ni) or two stages (Cu) with di-2-ethylhexylphosphoric acid (D2EHPA) diluted in kerosene (25⯰C, A/Oâ¯=â¯1 v/v) after adjusting the pH of the leachate. They were easily stripped by aqueous H2SO4. Iron, aluminum and tin did not interfere because they were masked by fluoride ions. Iron and aluminum were precipitated together as Na3FeF6â¯+â¯Na3AlF6 by careful addition of aqueous NaOH. Silicon, tin and fluoride ions were recovered together (Na2SiF6â¯+â¯Na2SnF6â¯+â¯NaF) by careful evaporation of the aqueous solution after SX of nickel. The tin salt was leached from this solid by absolute ethanol. High HF concentration (10â¯molâ¯L-1) in the leachant affected SX of Cu(II) and precipitation of iron/aluminum flurocomplexes since some NaF partially precipitated at acidic pH.
ABSTRACT
A eletronistagmografia (ENG) é fundamental na investigaçäo completa dos distúrbios do equilíbrio corporal, e popularizou-se progressivamente há cerca de 30 anos. Os sistemas convencionais apresentam registro em papel, e requerem a análise manual de todo o traçado. Ao longo da última década diversos sistemas computadorizados de ENG foram introduzidos no mercado mundial, mas elevados custos os tornam infreqüentes em nosso meio. Após dois anos de pesquisas, desenvolvemos um sistema próprio para aquisiçäo e processamento de dados para eletronistagmografia. O "SCE UCPEL/CASTANO" versäo 2.2 é conectado a qualquer microcomputador padräo IBM-PC 386 e tem custo comparável aos equipamentos convencionais de ENG , mas com significativas vantagens: 1) alta qualidade no tratamento digital do sinal elimina interferências (60Hz); 2) fácil operaçäo sem problemas mecânicos com papel ou tinta; 3)"ferramentas virtuais" no programa para medir velocidade angular da componente letal, amplitude e frequëncia; 4) cálculos automáticos de preponderância nas provas optocinéticas, calóricas e rotatórias; 5) resultados gráficos na tela do computador; 6) armazenamento e acesso instantâneo aos exames; 7) laudos padronizados de real utilidade ao médico
Subject(s)
Electronystagmography/instrumentation , Signal Processing, Computer-Assisted , Microcomputers/statistics & numerical data , Nystagmus, Pathologic/diagnosisABSTRACT
A eletronistagmografia (ENG) é uma importante etapa na investigaçäo completa dos distúrbios do equilíbrio corporal, popularizada a partir dos anos 60. Ao longo da última década diversos sistemas computadorizados de ENG foram introduzidos no mercado mundial, mas com custos elevados e portanto pouco freqüentes em nosso meio. Após dois anos de pesquisas, desenvolvemos um sistema próprio para aquisiçäo e processamento de dados par ENG, com dois canais. O sistema computadorizado e eletronistagmografia ("SCE UCPEL/CASTAGNO" versäo 2.2) é conectado a qualquer microcomputador padräo IBM-PC 386 ou superior, tendo custo comparável aos equipamentos convencionais de ENG, mas com significativas vantagens: 1) alta qualidade do tratamento digital do sinal elimina interferências (60Hz); 2) fácil operaçäo sem problemas mecânicos com papel ou tinta; 3) "ferramentas virtuais" no programa para medir velocidade angular da componente lente, amplitude e freqüência; 4) cálculos automáticos de preponderâncias nas provas optocinéticas, calóricas e rotatórias; 5) resultados gráficos na tela do computador; 6) armazenamento dos exames; 7) laudos padronizados de real utilidade ao médicos; 8) ENG de rápida execuçäo e interpretaçäo. Atualmente nosso grupo está desenvolvendo alguns complementos ao sistema, como processamento do terceiro canal (vectoniostagmografia computadorizada), análise automática do nistagmo, e controle do estímulo em barra de leds. Neste artigo também säo apresentados três casos ilustrativos da utilidade do sistema em pacientes normais, com Doença de Méniére, e neuromas do acústico