Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Type of study
Publication year range
2.
Biomedicines ; 11(12)2023 Dec 08.
Article in English | MEDLINE | ID: mdl-38137475

ABSTRACT

Intraocular pressure (IOP) lowering surgery has been shown to alter microvascular density in glaucoma patients. The aim of this study is to report changes in retinal flow density (FD) over the course of treatment with the Preserflo MicroShunt, using optical coherence tomography angiography (OCTA). 34 eyes from 34 patients who underwent Preserflo MicroShunt implantation were prospectively enrolled in this study. OCTA imaging was conducted at the superficial (SCP), deep (DCP) and radial peripapillary plexus (RPC) levels. The progression of FD and IOP was assessed at different time points from baseline to six months postoperatively for the entire patient population, as well as disease severity subgroups. The Preserflo MicroShunt achieved a significant reduction in IOP over the course of six months (median: 8 mmHg; p < 0.01). FD values of the SCP and DCP did not show significant fluctuations, even after adjusting for disease severity. FD of the RPC decreased significantly over the course of six months postoperatively from 42.31 at baseline to 39.59 at six months postoperatively (p < 0.01). The decrease in peripapillary FD was strongest in patients with advanced glaucoma (median: -3.58). These observations hint towards dysfunctional autoregulatory mechanisms in capillaries surrounding the optic nerve head in advanced glaucoma. In comparison, the microvascular structure of the macula appeared more resilient to changes in IOP.

3.
J Clin Med ; 12(13)2023 Jul 04.
Article in English | MEDLINE | ID: mdl-37445509

ABSTRACT

The Preserflo MicroShunt represents a novel glaucoma treatment device, necessitating long-term follow-up data to accurately assess its efficacy. The aim of this study is to report real-world data of a heterogenous glaucoma cohort who received Preserflo implantation at a specialized glaucoma clinic. A total of 160 eyes of 160 patients who underwent Preserflo MicroShunt implantation were retrospectively enrolled in this study. Patient characteristics, as well as success and failure rates, were assessed. The numbers of adverse events and revision procedures were recorded, along with any reduction in supplementary medication. The progression of intraocular pressure (IOP) was assessed over the course of 12 months, and fluctuations were analyzed. The overall success rate was 61.9% (complete success: 51.3%, qualified success: 10.6%). Revision surgery was performed in 25% of cases. Excessive hypotony occurred postoperatively in 54.4% of patients and regressed after 7 days in 88.8% of all cases. Median IOP decreased from 22 (interquartile range (IQR): 17-27) mmHg preoperatively to 14 (IQR 12-16) mmHg at 12 months postoperatively (p < 0.01). The median number of antiglaucomatous agents decreased from three to zero at latest follow-up. The Preserflo MicroShunt achieved a noticeable reduction in IOP over the course of 12 months in glaucoma patients, irrespective of disease severity or disease subtype. The frequency of postoperative adverse events and number for revision surgeries over the course of the follow-up period were low.

SELECTION OF CITATIONS
SEARCH DETAIL
...