Abdom Radiol (NY) ; 46(9): 4200-4209, 2021 09.
Article in English | MEDLINE | ID: mdl-33982186

ABSTRACT

OBJECTIVES: To evaluate the reproducibility of liver R2* measurements between a 2D cardiac ECG-gated and a 3D breath-hold liver CSE-MRI acquisition for liver iron quantification. METHODS: A total of 54 1.5 T MRI exams from 51 subjects (18 women, 36 men, age 35.2 ± 21.8) were included. These included two sub-studies with 23 clinical MRI exams from 19 patients identified retrospectively, 24 participants with known or suspected iron overload, and 7 healthy volunteers acquired prospectively. The 2D cardiac and the 3D liver R2* maps were acquired in the same exam. Either acquisitions were reconstructed using a complex R2* algorithm that accounts for the presence of fat and residual phase errors due to eddy currents. Data were analyzed using colocalized ROIs in the liver. RESULTS: Linear regression analysis demonstrated high Pearson's correlation and Lin's concordance coefficient for the overall study and both sub-studies. Bland-Altman analysis also showed good agreement, except for a slight increase of the mean R2* value above ~ 400 s-1. The Kolmogorow-Smirnow test revealed a non-normal distribution for (R2* 3D-R2* 2D) values from 0 to 600 s-1 in contrast to the 0-200 s-1 and 0-400 s-1 subpopulations. Linear regression analysis showed no relevant differences other than the intercept, likely due to only 7 measurements above 400 s-1. CONCLUSIONS: The results demonstrate that R2*-measurements in the liver are feasible using 2D cardiac R2* maps compared to 3D liver R2* maps as the reference. Liver R2* may be underestimated for R2* > 400 s-1 using the 2D cardiac R2* mapping method.


Subject(s)
Iron Overload , Iron , Adolescent , Adult , Female , Humans , Iron Overload/diagnostic imaging , Liver/diagnostic imaging , Magnetic Resonance Imaging , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Young Adult
2.
AJNR Am J Neuroradiol ; 31(3): 448-53, 2010 Mar.
Article in English | MEDLINE | ID: mdl-19875474

ABSTRACT

BACKGROUND AND PURPOSE: Fetal origin of the PCA is a common anatomic variation of the circle of Willis. On perfusion imaging, patients with unilateral fetal-type PCA may demonstrate left-right asymmetry that could mimic cerebrovascular disease. The aim of this study was to characterize the relationship between a fetal-type PCA and asymmetry of hemodynamic parameters derived from MR perfusion imaging. MATERIALS AND METHODS: We retrospectively reviewed MR perfusion studies of 36 patients to determine the relationship between hemodynamic and vascular asymmetries in the PCA territory. Perfusion asymmetry indices for the PCA territory were computed from maps of rCBF, rCBV, MTT, T(max), and FMT. Vascular asymmetry indices were derived from calibers of the PCA-P1 segments relative to the posterior communicating arteries. RESULTS: Asymmetrically smaller values of FMT and T(max) were observed with unilateral fetal-type PCA, and these were strongly correlated with the degree of vascular asymmetry (Spearman's rho = 0.76 and 0.74, respectively, P < 1 x 10(-6)). Asymmetries of rCBF, MTT, and rCBV were neither significant nor related to vascular asymmetry. CONCLUSIONS: Faster perfusion transit times are seen for parameters sensitive to macrovascular transit effects (eg, FMT and T(max)) ipsilateral to fetal origin of the PCA in proportion to the degree of arterial asymmetry. Knowledge of this normal variation is critical in the interpretation of perfusion studies because asymmetry could mimic cerebrovascular pathology.


Subject(s)
Cerebrovascular Circulation , Circle of Willis/anatomy & histology , Functional Laterality , Magnetic Resonance Imaging/methods , Posterior Cerebral Artery/anatomy & histology , Adult , Aged , Aged, 80 and over , Brain/blood supply , Brain Mapping , Female , Humans , Magnetic Resonance Imaging/standards , Male , Middle Aged , Reference Values , Retrospective Studies , Young Adult
3.
Magn Reson Med ; 48(3): 516-22, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12210917

ABSTRACT

Imaging of the blood vessels below the knee using contrast-enhanced (CE) MRI is challenging due to the need to coordinate image acquisition and arrival of the contrast in the targeted vessels. Time-resolved acquisitions have been successful in consistently capturing images of the arterial phase of the bolus of contrast agent in the distal extremities. Although time-resolved exams are robust in this respect, higher spatial resolution for the depiction of tight stenoses and the small vessels in the lower leg is desirable. A modification to a high-spatial-resolution T(1)-weighted pulse sequence (projection reconstruction-time resolved imaging of contrast kinetics (PR-TRICKS)) that improves the through-plane spatial resolution by a factor of 2 and maintains a high frame rate is presented. The undersampled PR-TRICKS pulse sequence has been modified to double the spatial resolution in the slice direction by acquiring high-spatial-frequency slice data only after first pass of the bolus of contrast agent. The acquisition reported in the present work (PR-hyperTRICKS) has been used to image healthy volunteers and patients with known vascular disease. The temporal resolution was found to be beneficial in capturing arterial phase images in the presence of asymmetric filling of vessels.


Subject(s)
Image Processing, Computer-Assisted , Leg/blood supply , Magnetic Resonance Angiography/methods , Peripheral Vascular Diseases/physiopathology , Contrast Media , Humans , Imaging, Three-Dimensional
4.
Med Phys ; 28(4): 688-700, 2001 Apr.
Article in English | MEDLINE | ID: mdl-11339767

ABSTRACT

Materials that simultaneously mimic soft tissue in vivo for magnetic resonance imaging (MRI), ultrasound (US), and computed tomography (CT) for use in a prostate phantom have been developed. Prostate and muscle mimicking materials contain water, agarose, lipid particles, protein, Cu++, EDTA, glass beads, and thimerosal (preservative). Fat was mimicked with safflower oil suffusing a random mesh (network) of polyurethane. Phantom material properties were measured at 22 degrees C. (22 degrees C is a typical room temperature at which phantoms are used.) The values of material properties should match, as well as possible, the values for tissues at body temperature, 37 degrees C. For MRI, the primary properties of interest are T1 and T2 relaxations times, for US they are the attenuation coefficient, propagation speed, and backscatter, and for CT, the x-ray attenuation. Considering the large number of parameters to be mimicked, rather good agreement was found with actual tissue values obtained from the literature. Using published values for prostate parenchyma, T1 and T2 at 37 degrees C and 40 MHz are estimated to be about 1,100 and 98 ms, respectively. The CT number for in vivo prostate is estimated to be 45 HU (Hounsfield units). The prostate mimicking material has a T1 of 937 ms and a T2 of 88 ms at 22 degrees C and 40 MHz; the propagation speed and attenuation coefficient slope are 1,540 m/s and 0.36 dB/cm/MHz, respectively, and the CT number of tissue mimicking prostate is 43 HU. Tissue mimicking (TM) muscle differs from TM prostate in the amount of dry weight agarose, Cu++, EDTA, and the quality and quantity of glass beads. The 18 microm glass beads used in TM muscle increase US backscatter and US attenuation; the presence of the beads also has some effect on T1 but no effect on T2. The composition of tissue-mimicking materials developed is such that different versions can be placed in direct contact with one another in a phantom with no long term change in US, MRI, or CT properties. Thus, anthropomorphic phantoms can be constructed.


Subject(s)
Phantoms, Imaging , Adipose Tissue/diagnostic imaging , Humans , Magnetic Resonance Imaging/methods , Male , Muscles/diagnostic imaging , Prostate/diagnostic imaging , Temperature , Time Factors , Tomography, X-Ray Computed/methods
5.
Magn Reson Med ; 43(4): 503-9, 2000 Apr.
Article in English | MEDLINE | ID: mdl-10748424

ABSTRACT

MR phase-contrast techniques provide velocity-sensitive angiograms and quantitative flow measurements but require long scan times. Recently it has been shown that undersampled projection reconstruction can acquire higher resolution per unit time than Fourier techniques with acceptable artifacts when used in contrast-enhanced MR angiography. Undersampled projection reconstruction has similar potential for phase-contrast acquisitions. Flow sensitization gradients are used with projection trajectories to acquire velocity-dependent phase information. An acquisition scheme that acquires three flow encoding directions on three sets of angular-interleaved projections is introduced. Depending on the resolution, acquisition times for 3D datasets can decrease by factors of two to four.


Subject(s)
Circle of Willis/anatomy & histology , Image Enhancement/methods , Magnetic Resonance Angiography/instrumentation , Phantoms, Imaging , Artifacts , Blood Flow Velocity , Humans , Magnetic Resonance Angiography/methods , Models, Theoretical , Pulsatile Flow , Reference Values , Sensitivity and Specificity , Spectroscopy, Fourier Transform Infrared
6.
Magn Reson Med ; 43(2): 170-6, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10680679

ABSTRACT

In time-resolved contrast-enhanced 3D MR angiography, spatial resolution is traded for high temporal resolution. A hybrid method is presented that attempts to reduce this tradeoff in two of the spatial dimensions. It combines an undersampled projection acquisition in two dimensions with variable rate k-space sampling in the third. Spatial resolution in the projection plane is determined by readout resolution and is limited primarily by signal-to-noise ratio. Oversampling the center of k-space combined with temporal k-space interpolation provides time frames with minimal venous contamination. Results demonstrating improved resolution in phantoms and volunteers are presented using angular undersampling factors up to eight with acceptable projection reconstruction artifacts.


Subject(s)
Contrast Media , Magnetic Resonance Angiography/methods , Abdomen/anatomy & histology , Algorithms , Artifacts , Feasibility Studies , Humans , Magnetic Resonance Angiography/statistics & numerical data , Phantoms, Imaging/statistics & numerical data , Time Factors
7.
Magn Reson Med ; 43(1): 91-101, 2000 Jan.
Article in English | MEDLINE | ID: mdl-10642735

ABSTRACT

Undersampled projection reconstruction (PR) is investigated as an alternative method for MRA (MR angiography). In conventional 3D Fourier transform (FT) MRA, resolution in the phase-encoding direction is proportional to acquisition time. Since the PR resolution in all directions is determined by the readout resolution, independent of the number of projections (Np), high resolution can be generated rapidly. However, artifacts increase for reduced Np. In X-ray CT, undersampling artifacts from bright objects like bone can dominate other tissue. In MRA, where bright, contrast-filled vessels dominate, artifacts are often acceptable and the greater resolution per unit time provided by undersampled PR can be realized. The resolution increase is limited by SNR reduction associated with reduced voxel size. The hybrid 3D sequence acquires fractional echo projections in the k(x)-k(y) plane and phase encodings in k(z). PR resolution and artifact characteristics are demonstrated in a phantom and in contrast-enhanced volunteer studies.


Subject(s)
Carotid Arteries/anatomy & histology , Femoral Artery/anatomy & histology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Phantoms, Imaging , Pulmonary Artery/anatomy & histology , Artifacts , Contrast Media , Humans , Sensitivity and Specificity
8.
Magn Reson Med ; 40(5): 656-65, 1998 Nov.
Article in English | MEDLINE | ID: mdl-9797147

ABSTRACT

Coronary artery disease continues to be the leading cause of death for adults in the United States. Magnetic resonance imaging (MR) has the potential to dramatically impact the diagnosis of heart disease by noninvasively providing a wide range of anatomic and physiologic information. Previous research has shown that coronary flow, one component of a complete examination, can be accurately measured in the left anterior descending artery in vivo. The current work validates MR flow measurements in canine circumflex arteries using transit time ultrasound as a standard. The circumflex artery experiences greater in-plane motion and is a more stringent test for flow measurement accuracy. This work also compares two methods of processing MR velocity data, phase difference and complex difference techniques, and examines the sources of error present in the animal validation model. Phase difference processing with a 30% magnitude threshold best matched the mean ultrasound flow values (30% PD = 1.04 x US + 1.49, r = 0.94), but it was very sensitive to vessel boundary identification. The complex difference process was less sensitive to vessel boundary identification and correlated well with the transit time ultrasound despite systematic underestimations. The reasons for the discrepancies are shown to stem from a number of possible sources including variability of the ultrasound standard, low signal-to-noise ratios in the MR images, sensitivity of the MR technique to vessel boundary identification, and motion artifacts in the images.


Subject(s)
Coronary Circulation/physiology , Coronary Vessels/anatomy & histology , Coronary Vessels/physiology , Endosonography/methods , Magnetic Resonance Imaging/methods , Signal Processing, Computer-Assisted , Animals , Coronary Vessels/diagnostic imaging , Disease Models, Animal , Dogs , Electrocardiography , Hemodynamics/physiology , Magnetic Resonance Imaging/instrumentation , Pulsatile Flow , Rheology , Sensitivity and Specificity
9.
Mo Nurse ; 65(4): 7, 1996.
Article in English | MEDLINE | ID: mdl-9391382