Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Eur J Clin Microbiol Infect Dis ; 34(10): 1999-2007, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26173694

ABSTRACT

Candida spp. usually colonize ulcerative lesions of atrophic mucosa in patients with chemotherapy-induced oral mucositis inducing severe inflammation. The spread of antifungal-resistant strains strongly encouraged the search of complementary or alternative therapeutic strategies to cure inflamed mucosa. In this paper, we studied the effects of a near-infrared (NIR) laser system with dual-wavelength emission (808 nm + 904 nm) on the survival and inflammatory potential of C. albicans, C. glabrata, and C. parapsilosis. Laser treatment was performed with a Multiwave Locked System laser. Survival and apoptosis of fungal strains were evaluated by colony-forming units (CFU) counting and annexin V staining. Cytokine production was evaluated by ImmunoPlex array. Laser treatment significantly affected the survival of Candida spp. by inducing apoptosis and induced a lower production of inflammatory cytokines by dendritic cells compared to untreated fungi. No differences in the survival and inflammatory potential were recorded in treated or untreated Saccharomyces cerevisiae cells, used as the control non-pathogenic microorganism. Laser treatment altered the survival and inflammatory potential of pathogenic Candida spp. These data provide experimental support to the use of NIR laser radiation as a co-adjuvant of antifungal therapy in patients with oral mucositis (OM) complicated by Candida infections.


Subject(s)
Antineoplastic Agents/adverse effects , Candida/radiation effects , Candidiasis/chemically induced , Candidiasis/radiotherapy , Laser Therapy , Stomatitis/chemically induced , Stomatitis/radiotherapy , Apoptosis/radiation effects , Humans , Inflammation/radiotherapy
2.
Radiol Med ; 115(3): 354-67, 2010 Apr.
Article in English, Italian | MEDLINE | ID: mdl-19902329

ABSTRACT

PURPOSE: This study aimed to evaluate the diagnostic accuracy of stress electrocardiogram (ECG) and computed tomography coronary angiography (CTCA) for the detection of significant coronary artery stenosis (> or =50%) in the real world using conventional CA as the reference standard. MATERIALS AND METHODS: A total of 236 consecutive patients (159 men, 77 women; mean age 62.8+/-10.2 years) at moderate risk and with suspected coronary artery disease (CAD) were enrolled in the study and underwent stress ECG, CTCA and CA. The CTCA scan was performed after i.v. administration of a 100-ml bolus of iodinated contrast material. The stress ECG and CTCA reports were used to evaluate diagnostic accuracy compared with CA in the detection of significant stenosis > or =50%. RESULTS: We excluded 16 patients from the analysis because of the nondiagnostic quality of stress ECG and/or CTCA. The prevalence of disease demonstrated at CA was 62% (n=220), 51% in the population with comparable stress ECG and CTCA (n=147) and 84% in the population with equivocal stress ECG (n=73). Stress ECG was classified as equivocal in 73 cases (33.2%), positive in 69 (31.4%) and negative in 78 (35.5%). In the per-patient analysis, the diagnostic accuracy of stress ECG was sensitivity 47%, specificity 53%, positive predictive value (PPV) 51% and negative predictive value (NPV) 49%. On stress ECG, 40 (27.2%) patients were misclassified as negative, and 34 (23.1%) patients with nonsignificant stenosis were overestimated as positive. The diagnostic accuracy of CTCA was sensitivity 96%, specificity 65%, PPV 74% and NPV 94%. CTCA incorrectly classified three (2%) as negative and 25 (17%) as positive. The difference in diagnostic accuracy between stress ECG and CTCA was significant (p<0.01). CONCLUSIONS: CTCA in the real world has significantly higher diagnostic accuracy compared with stress ECG and could be used as a first-line study in patients at moderate risk.


Subject(s)
Coronary Angiography/methods , Coronary Stenosis/diagnosis , Electrocardiography/methods , Exercise Test , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Chi-Square Distribution , Contrast Media , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/physiopathology , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Sensitivity and Specificity
3.
Minerva Cardioangiol ; 57(3): 349-57, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19513014

ABSTRACT

Cardiac computed tomography (CT) is a fast developing technique. In 10 years it developed from investigative tool into a clinical reality. The technology drive has been the key to success for this technique which is to date the only non invasive clinical tool for coronary angiographic assessment. Technical background is quite complex and the newer solutions are aiming at reducing the scan time and the radiation dose while improving temporal resolution, contrast resolution and ultimately image quality. The key technical development has been in the late 1990, the introduction of ECG triggering/gating techniques. Spatial resolution has also been improved reaching sub-millimeter performance. The latest innovations provide fast coverage with >64 slice detectors, high spatial resolution with 0.5 mm slice thickness, high temporal resolution with <100 ms in hardware, and higher contrast resolution with the forthcoming dual-energy solutions. Recently, also dose issues have been exploited and current state of the art technology are able to perform cardiac CT with 1-2 mSv. These improvements put cardiac CT as the most promising clinical tool for the non invasive assessment of coronary arteries.


Subject(s)
Coronary Angiography/instrumentation , Coronary Vessel Anomalies/diagnostic imaging , Algorithms , Cardiovascular Diseases/diagnostic imaging , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Restenosis/diagnostic imaging , Coronary Vessel Anomalies/diagnosis , Humans , Practice Guidelines as Topic , Radiation Dosage , Sensitivity and Specificity , Tomography, X-Ray Computed/instrumentation
4.
Int J Cardiol ; 133(2): 205-12, 2009 Apr 03.
Article in English | MEDLINE | ID: mdl-18313156

ABSTRACT

We report a case-series of seven patients with Tako-Tsubo cardiomyopathy (TTC) and at least one concomitant >or=50% coronary stenosis. Each case involves a female patient who presented symptoms and an electrocardiogram compatible with acute coronary syndrome, mild troponin I elevation, a ventriculogram showing left ventricle (LV) apical or midventricular ballooning (classical or variant TTC), an angiogram showing at least one >or=50% stenosis and a cardiac magnetic resonance showing no myocardial late Gadolinium enhancement. Full recovery of normal LV contractility after the event was required to confirm TTC. Our report presents the case for the opportunity to modify the TTC definition, removing the requirement for absence of coronary stenosis not to exclude patients with bystander coronary lesions, who are probably under diagnosed as per the original TTC definition.


Subject(s)
Coronary Stenosis/diagnosis , Takotsubo Cardiomyopathy/diagnosis , Aged , Aged, 80 and over , Coronary Stenosis/complications , Female , Humans , Takotsubo Cardiomyopathy/complications
5.
Radiol Med ; 113(2): 163-80, 2008 Mar.
Article in English, Italian | MEDLINE | ID: mdl-18386119

ABSTRACT

PURPOSE: This study was done to evaluate the diagnostic accuracy of 64-slice computed tomography coronary angiography (CTCA) for the detection of significant coronary artery stenosis in the real clinical world. MATERIALS AND METHOD: From the CTCA database of our institution, we enrolled 145 patients (92 men, 52 women, mean age 63.4 +/- 10.2 years) with suspected coronary artery disease. All patients presented with atypical or typical chest pain and underwent CTCA and conventional coronary angiography (CA). For the CTCA scan (Sensation 64, Siemens, Germany), we administered an IV bolus of 100 ml of iodinated contrast material (Iomeprol 400 mgI/ml, Bracco, Italy). The CTCA and CA reports used to evaluate diagnostic accuracy adopted > or =50% and > or =70%, respectively, as thresholds for significant stenosis. RESULT: Eleven patients were excluded from the analysis because of the nondiagnostic quality of CTCA. The prevalence of disease demonstrated at CA was 63% (84/134). Sensitivity, specificity and positive and negative predictive values for CTCA on a per-segment, per-vessel, and per-patient basis were 75.6%, 85.1%, 97.6%; 86.9%, 81.8%, 58.0%; 48.2%, 68.1%, 79.6%; and 95.7%, 92.3%, 93.5%, respectively. Only two out of 134 eligible patients were false negative. Heart rate did not significantly influence diagnostic accuracy, whereas the absence or minimal presence of coronary calcification improved diagnostic accuracy. The positive and negative likelihood ratios at the per-patient level were 2.32 and 0.041, respectively. CONCLUSION: CTCA in the real clinical world shows a diagnostic performance lower than reported in previous validation studies. The excellent negative predictive value and negative likelihood ratio make CTCA a noninvasive gold standard for exclusion of significant coronary artery disease.


Subject(s)
Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Tomography, X-Ray Computed , Aged , Contrast Media/pharmacology , Coronary Angiography/methods , Female , Humans , Iopamidol/analogs & derivatives , Italy , Male , Medical Records , Middle Aged , Odds Ratio , Predictive Value of Tests , Research Design , Sensitivity and Specificity , Tomography, X-Ray Computed/methods
6.
Minerva Cardioangiol ; 56(1): 1-11, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18432163

ABSTRACT

AIM: Elective percutaneous coronary intervention (PCI) of left main coronary artery disease remains an important challenge in interventional cardiology. Nonetheless, this procedure is useful for patients with significant left main stenosis who are candidates for revascularization but unsuitable for coronary artery bypass graft. In this study the Authors sought to evaluate the safety and long-term mortality of PCI of left main coronary artery disease. Secondary endpoints were to analyse long-term mortality in various categories (patients<75 years vs patients<75 years, males vs females, drug eluting stents [DES] vs bare metal stents [BMS]). METHODS: Between January 2003 and December 2006, 131 patients who consecutively under-went PCI on left main stem were reviewed. The mean follow-up time was 14.0+/-10.8 months. Survival curves were plotted with the Kaplan-Meier method and compared with the Log-rank test. RESULTS: The Kaplan-Meier curves did not show statistically significant differences in terms of all-cause mortality at follow-up between protected and unprotected left main coronary disease (12% vs 14% respectively, P=0.67). In the protected left main group, there was a significantly higher use of DES compared with unprotected left main group (59% vs 43%, P=0.02). CONCLUSION: The data show that PCI for left main coronary disease is feasible, safe and with an acceptable long-term mortality rate in patients at high-surgical risk unsuitable for surgical revascularization.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Myocardial Revascularization/methods , Aged , Aged, 80 and over , Coronary Artery Bypass/methods , Coronary Artery Disease/surgery , Drug-Eluting Stents , Elective Surgical Procedures/methods , Feasibility Studies , Female , Humans , Italy , Kaplan-Meier Estimate , Male , Middle Aged , Retrospective Studies , Severity of Illness Index , Stents , Survival Analysis
7.
Radiol Med ; 112(7): 969-81, 2007 Oct.
Article in English, Italian | MEDLINE | ID: mdl-17952682

ABSTRACT

PURPOSE: Our aim was to evaluate the diagnostic accuracy of 64-slice computed tomography coronary angiography (MSCT-CA) for detecting significant stenosis (>or=50% lumen reduction) in a population of patients at low to intermediate risk. MATERIALS AND METHODS: We studied 72 patients (38 men, 34 women, mean age 53.9+/-8.0 years) with atypical or typical chest pain and stratified in the low-to intermediate risk category. MSCT-CA (Sensation 64 Cardiac, Siemens, Germany) was performed after IV administration of 100 ml of iodinated contrast material (Iomeprol 400 mgI/ml, Bracco, Italy). Two observers, blinded to the results of conventional coronary angiography (CAG), assessed the MSCT-CA scans in consensus. Diagnostic accuracy for detecting significant stenosis was calculated. RESULTS: CAG demonstrated the absence of significant disease in 70.1% of patients (51/72). No patient was excluded from MSCT-CA. There were 37 significant lesions on 1,098 available coronary segments. Sensitivity, specificity and positive and negative predictive value of MSCT-CA for detecting significant coronary artery on a per-segment basis were 100%, 98.6%, 71.2% and 100%, respectively. All patients with at least one significant lesion were correctly identified by MSCT-CA. MSCT-CA scored 15 false positives on a per-segment base, which affected only marginally the per-patient performance (only one false positive). CONCLUSIONS: We concluded that 64-slice CT-CA is a diagnostic modality with high sensitivity and negative predictive value in patients at low to intermediate risk.


Subject(s)
Coronary Angiography/methods , Coronary Disease/diagnostic imaging , Tomography, Spiral Computed/methods , Algorithms , Chest Pain , Contrast Media , Coronary Stenosis/diagnostic imaging , Data Interpretation, Statistical , Electrocardiography , Female , Humans , Iopamidol/analogs & derivatives , Male , Middle Aged , Predictive Value of Tests , Risk Factors , Sensitivity and Specificity , Ventricular Function, Left
8.
Radiol Med ; 112(4): 526-37, 2007 Jun.
Article in English, Italian | MEDLINE | ID: mdl-17568993

ABSTRACT

PURPOSE: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis. MATERIALS AND METHODS: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml, Iomeron, Bracco) and a bolus chaser (40 ml of saline), the scan was completed in <12 s. All coronary segments with a stent were assessed on 64-CT by two observers in consensus and judged as: patent, with intimal hyperplasia (lumen reduction of <50%), with in-stent restenosis (> or =50%), or with in-stent occlusion (100%). The consensus reading was compared with conventional coronary angiography. RESULTS: Four patients were excluded because of insufficient image quality. In the remaining 91, we assessed 102 stents (31 RCA; 10 LM; 54 LAD; 7 CX). In 14 (13.7%) stents, in-stent restenosis (n=8) or in-stent occlusion (n=6) was found. Intimal hyperplasia was detected in 11 (10.8%) stents. The sensitivity and negative predictive value of 64-CT for in-stent occlusion were 100% and 100%, respectively, whereas for all stenoses, >50% they were 92.9% and 98.7%, respectively. CONCLUSIONS: We found that 64-CT has a high diagnostic accuracy for the detection of in-stent restenosis in a selected patient population.


Subject(s)
Coronary Angiography/methods , Coronary Restenosis/diagnostic imaging , Stents , Tomography, X-Ray Computed , Female , Humans , Male , Middle Aged , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...