Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Oper Neurosurg (Hagerstown) ; 22(2): 80-86, 2022 02 01.
Article in English | MEDLINE | ID: mdl-35007273

ABSTRACT

BACKGROUND: Minimally invasive surgical techniques have reinvigorated the role of surgical options for spontaneous intracranial hematomas; however, they are limited by the lack of real-time feedback on the extent of hematoma evacuation. OBJECTIVE: To describe the development of a MRI-guided catheter-based aspiration system, the ClearPoint Pursuit Neuroaspiration Device (ClearPoint Neuro) and validation in phantom models. METHODS: In this preclinical experimental trial, 8 phantom brains with skull models were created to simulate an intracranial hematoma with 2 clot sizes, 30 cc (small clot) and 60 cc (large clot). After registration, the aspiration catheter (Pursuit device) was aligned to the desired planned trajectory. The aspiration of the clot was performed under real-time MRI scan in 3 orthogonal views. The primary end point was reduction of the clot volume to less than 15 cc or 70% of the original clot volume. RESULTS: Successful completion of clot evacuation was achieved in all models. The average postaspiration clot volume was 9.5 cc (8.7 cc for small clots and 10.2 cc for large clots). The average percentage reduction of clot volume was 76.3% (range 58.7%-85.2%). The average total procedure time (from frame registration to final postaspiration clot assessment) was 50 min. The average aspiration time was 6.9 min. CONCLUSION: This preclinical trial confirms the feasibility and efficacy of MRI-guided aspiration under real-time image guidance in simulation models for intracranial hematoma. Clinical use of the system in patients would further validate its efficacy and safety.


Subject(s)
Cerebral Hemorrhage , Tomography, X-Ray Computed , Cerebral Hemorrhage/diagnostic imaging , Cerebral Hemorrhage/surgery , Feasibility Studies , Hematoma/diagnostic imaging , Hematoma/surgery , Humans , Magnetic Resonance Imaging , Treatment Outcome
2.
Int J Radiat Oncol Biol Phys ; 99(3): 618-626, 2017 11 01.
Article in English | MEDLINE | ID: mdl-28843373

ABSTRACT

PURPOSE: We designed and built dedicated active magnetic resonance (MR)-tracked (MRTR) stylets. We explored the role of MRTR in a prospective clinical trial. METHODS AND MATERIALS: Eleven gynecologic cancer patients underwent MRTR to rapidly optimize interstitial catheter placement. MRTR catheter tip location and orientation were computed and overlaid on images displayed on in-room monitors at rates of 6 to 16 frames per second. Three modes of actively tracked navigation were analyzed: coarse navigation to the approximate region around the tumor; fine-tuning, bringing the stylets to the desired location; and pullback, with MRTR stylets rapidly withdrawn from within the catheters, providing catheter trajectories for radiation treatment planning (RTP). Catheters with conventional stylets were inserted, forming baseline locations. MRTR stylets were substituted, and catheter navigation was performed by a clinician working inside the MRI bore, using monitor feedback. RESULTS: Coarse navigation allowed repositioning of the MRTR catheters tips by 16 mm (mean), relative to baseline, in 14 ± 5 s/catheter (mean ± standard deviation [SD]). The fine-tuning mode repositioned the catheter tips by a further 12 mm, in 24 ± 17 s/catheter. Pullback mode provided catheter trajectories with RTP point resolution of ∼1.5 mm, in 1 to 9 s/catheter. CONCLUSIONS: MRTR-based navigation resulted in rapid and optimal placement of interstitial brachytherapy catheters. Catheters were repositioned compared with the initial insertion without tracking. In pullback mode, catheter trajectories matched computed tomographic precision, enabling their use for RTP.


Subject(s)
Brachytherapy/instrumentation , Genital Neoplasms, Female/radiotherapy , Magnetic Resonance Imaging, Interventional/instrumentation , Radiotherapy, Image-Guided/methods , Adult , Aged , Aged, 80 and over , Brachytherapy/methods , Catheters , Female , Genital Neoplasms, Female/diagnostic imaging , Genital Neoplasms, Female/pathology , Humans , Middle Aged , Prospective Studies , Radiotherapy, Image-Guided/instrumentation
3.
J Magn Reson Imaging ; 40(2): 490-5, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24677517

ABSTRACT

PURPOSE: To compare the spatial accuracy of three typical active tracking sequences using a new, unique phantom design. MATERIALS AND METHODS: Three different tracking sequences (Single Echo, Dual Echo and Hadamard Multiplexed) were compared with each other in a phantom study with respect to their positional accuracy. A custom-built phantom was constructed to conduct the experiments with precise framework conditions which facilitated sufficient measurement accuracy. An electrophysiology catheter incorporating four micro-coils was used as an interventional device. Tracking profiles were acquired in all three spatial dimensions and validated against the distances that were measured by a Vernier caliper in combination with a three-dimensional reference scan. RESULTS: The Bland-Altman plots demonstrated that all three sequences show < 1.5 mm positional error. The measurement accuracy of Single Echo and Double Echo are prone to off-resonances, whereas Hadamard Encoding is immune to it. CONCLUSION: The developed phantom enabled the performance of objective measurements of the accuracy of different active tracking sequences. The proposed setup allows for objectively contrasting different methods for interventional procedures.


Subject(s)
Algorithms , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Interventional/instrumentation , Magnetic Resonance Imaging, Interventional/methods , Phantoms, Imaging , Equipment Design , Equipment Failure Analysis , Humans , Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity , Signal Processing, Computer-Assisted
4.
Heart Rhythm ; 8(2): 295-303, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21034854

ABSTRACT

BACKGROUND: Magnetic resonance imaging (MRI) allows visualization of location and extent of radiofrequency (RF) ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT -RI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. OBJECTIVE: The purpose of this study was to develop a 3-Tesla RT MRI-based catheter ablation and lesion visualization system. METHODS: RF energy was delivered to six pigs under RT MRI guidance. A novel MRI-compatible mapping and ablation catheter was used. Under RT MRI, this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bipolar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2W) half Fourier acquisition with single-shot turbo spin echo (HASTE) sequence during ablation. RESULTS: RT visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or the lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement MRI and macroscopic tissue examination. CONCLUSION: MRI-compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT MRI guidance. Recording electrograms during RT imaging also is feasible. RT visualization of lesion as it forms during RF energy delivery is possible and was demonstrated using T2W HASTE imaging.


Subject(s)
Catheter Ablation/methods , Heart Atria/pathology , Heart Atria/surgery , Magnetic Resonance Imaging/methods , Radiographic Image Enhancement , Animals , Disease Models, Animal , Female , Gadolinium , Radiography, Interventional/methods , Sensitivity and Specificity , Swine
SELECTION OF CITATIONS
SEARCH DETAIL