Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Bioanalysis ; 11(18s): 1-228, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31565956

ABSTRACT

The 13th GCC Closed Forum for Bioanalysis was held in New Orleans, Louisiana, USA on April 5th, 2019. This GCC meeting was organized to discuss the contents of the 2019 ICH M10 Bioanalytical Method Validation Draft Guideline published in February 2019 and consolidate the feedback of the GCC members. In attendance were 63 senior-level participants from eight countries representing 44 bioanalytical CRO companies/sites. This event represented a unique opportunity for CRO bioanalytical experts to share their opinions and concerns regarding the ICH M10 Bioanalytical Method Validation Draft Guideline and to build unified comments to be provided to the ICH.


Subject(s)
Biomarkers/analysis , Guidelines as Topic , Humans , Reproducibility of Results , Research Design
2.
Bioanalysis ; 11(12): 1129-1138, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31319683

ABSTRACT

The 12th GCC Closed Forum was held in Philadelphia, PA, USA, on 9 April 2018. Representatives from international bioanalytical Contract Research Organizations were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at the meeting included: critical reagents; oligonucleotides; certificates of analysis; method transfer; high resolution mass spectrometry; flow cytometry; recent regulatory findings and case studies involving stability and nonclinical immunogenicity. Conclusions and consensus from discussions of these topics are included in this article.


Subject(s)
Certification , Chemistry Techniques, Analytical , Flow Cytometry , Mass Spectrometry , Oligonucleotides/analysis , Social Control, Formal , Societies, Scientific , Indicators and Reagents/chemistry
3.
Bioanalysis ; 11(7): 645-653, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30993999

ABSTRACT

Over the last decade, the use of biomarker data has become integral to drug development. Biomarkers are not only utilized for internal decision-making by sponsors; they are increasingly utilized to make critical decisions for drug safety and efficacy. As the regulatory agencies are routinely making decisions based on biomarker data, there has been significant scrutiny on the validation of biomarker methods. Contract research organizations regularly use commercially available immunoassay kits to validate biomarker methods. However, adaptation of such kits in a regulated environment presents significant challenges and was one of the key topics discussed during the 12th Global Contract Research Organization Council for Bioanalysis (GCC) meeting. This White Paper reports the GCC members' opinion on the challenges facing the industry and the GCC recommendations on the classification of commercial kits that can be a win-win for commercial kit vendors and end users.


Subject(s)
Biological Assay/methods , Biomarkers/analysis , Biological Assay/standards , Drug Discovery , Humans , Ligands , Pharmaceutical Preparations/chemistry , Pharmaceutical Preparations/metabolism , Pharmaceutical Preparations/standards , Quality Control , Reagent Kits, Diagnostic , Reference Standards , Societies, Pharmaceutical , Surveys and Questionnaires
4.
Bioanalysis ; 10(7): 433-444, 2018 Apr 01.
Article in English | MEDLINE | ID: mdl-29701066

ABSTRACT

The 11th Global CRO Council Closed Forum was held in Universal City, CA, USA on 3 April 2017. Representatives from international CRO members offering bioanalytical services were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The second CRO-Pharma Scientific Interchange Meeting was held on 7 April 2017, which included Pharma representatives' sharing perspectives on the topics discussed earlier in the week with the CRO members. The issues discussed at the meetings included cumulative stability evaluations, matrix stability evaluations, the 2016 US FDA Immunogenicity Guidance and recent and unexpected FDA Form 483s on immunogenicity assays, the bioanalytical laboratory's role in writing PK sample collection instructions, biosimilars, CRO perspectives on the use of chiral versus achiral methods, hybrid LBA/LCMS assays, applications of fit-for-purpose validation and, at the Global CRO Council Closed Forum only, the status and trend of current regulated bioanalytical practice in China under CFDA's new BMV policy. Conclusions from discussions of these topics at both meetings are included in this report.


Subject(s)
Biological Assay/methods , Biomarkers/analysis , Biosimilar Pharmaceuticals/therapeutic use , China , Humans , Research Design
5.
Antimicrob Agents Chemother ; 59(1): 475-81, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25385101

ABSTRACT

Tedizolid, a novel oxazolidinone antibacterial, was administered to Long Evans rats by oral gavage once daily for up to 9 months at doses near the maximum tolerated dose (MTD) to evaluate for potential neurotoxicity. Mean plasma exposures of tedizolid at the low-, medium-, and high-dose levels (7.5, 15, and 30 mg/kg of body weight/day for males; 2.5, 5, and 10 mg/kg/day for females) were similar between males and females and were 1.8-, 3.9-, and 8.0-fold greater than exposures in patients at the therapeutic dose (200 mg once daily). Evaluated endpoints included survival, clinical observations, body weight, and food consumption. At 1, 3, 6, and 9 months, ophthalmic examinations, functional observational batteries, and locomotor activity measures were conducted, brain weights/sizes were recorded, and perfusion-fixed tissues were collected from 12 rats/sex/group/time point. A detailed morphological assessment was conducted on brain, eyes, optic nerve/tract, spinal cord, peripheral nerves (includes sciatic, sural, tibial, peroneal, trigeminal), and skeletal muscle. At the end of 9 months, less body weight gain was seen in high-dose males (-6.7%) and females (-5.8%) compared with that seen in controls. There were no tedizolid-related adverse neurobehavioral effects or tedizolid-related histopathologic changes in the central/peripheral nervous systems, including the optic nerve. Results of this study indicate that tedizolid was not neurotoxic when administered long term to pigmented rats at doses near the MTD, which were up to 8-fold higher than the human therapeutic exposure.


Subject(s)
Anti-Bacterial Agents/adverse effects , Linezolid/adverse effects , Neurotoxicity Syndromes/mortality , Organophosphates/adverse effects , Oxazoles/adverse effects , Animals , Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/pharmacology , Female , Linezolid/administration & dosage , Linezolid/pharmacology , Male , Organophosphates/administration & dosage , Organophosphates/pharmacology , Oxazoles/administration & dosage , Oxazoles/pharmacology , Rats , Rats, Inbred LEC
SELECTION OF CITATIONS
SEARCH DETAIL
...