Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Sens ; 9(5): 2294-2309, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38654679

ABSTRACT

Bioanalyte collection by blood draw is a painful process, prone to needle phobia and injuries. Microneedles can be engineered to penetrate the epidermal skin barrier and collect analytes from the interstitial fluid, arising as a safe, painless, and effective alternative to hypodermic needles. Although there are plenty of reviews on the various types of microneedles and their use as drug delivery systems, there is a lack of systematization on the application of polymeric microneedles for diagnosis. In this review, we focus on the current state of the art of this field, while providing information on safety, preclinical and clinical trials, and market distribution, to outline what we believe will be the future of health monitoring.


Subject(s)
Needles , Polymers , Humans , Polymers/chemistry , Drug Delivery Systems/instrumentation , Animals , Microinjections/instrumentation , Microinjections/methods , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods
2.
Nanotechnology ; 34(36)2023 Jun 23.
Article in English | MEDLINE | ID: mdl-37267925

ABSTRACT

As an additive manufacturing process, material jetting techniques allow to selectively deposit droplets of materials in liquid or powder form through a small-diameter aperture, such as a nozzle of a print head. For the fabrication of printed electronics, a variety of inks and dispersions of functional materials can be deposited by drop-on-demand printing on rigid and flexible substrates. In this work, zero-dimensional multi-layer shell-structured fullerene material, also known as carbon nano-onion (CNO) or onion-like carbon, is printed on polyethylene terephthalate substrates using drop-on-demand inkjet printing. CNOs are produced using a low-cost flame synthesis technique and characterized by electron microscopy, Raman, x-ray photoelectron spectroscopy, and specific surface area and pore size measurements. The produced CNO material has an average diameter of ∼33 nm, pore diameter in the range ∼2-40 nm and a specific surface area of 160 m2.g-1. The CNO dispersions in ethanol have a reduced viscosity (∼1.2 mPa.s) and are compatible with commercial piezoelectric inkjet heads. The jetting parameters are optimized to avoid satellite drops and to obtain a reduced drop volume (52 pL), resulting in optimal resolution (220µm) and line continuity. A multi-step process is implemented without inter-layer curing and a fine control over the CNO layer thickness is achieved (∼180 nm thick layer after 10 printing passes). The printed CNO structures show an electrical resistivity of ∼600 Ω.m, a high negative temperature coefficient of resistance (-4.35 × 10-2°C-1) and a marked dependency on relative humidity (-1.29 × 10-2RH%-1). The high sensitivity to temperature and humidity, combined to the large specific area of the CNOs, make this material and the corresponding ink a viable prospect for inkjet-printed technologies, such as environmental and gas sensors.


Subject(s)
Carbon , Fullerenes , Onions , Electronics , Polyethylene Terephthalates
3.
Polymers (Basel) ; 14(18)2022 Sep 06.
Article in English | MEDLINE | ID: mdl-36145852

ABSTRACT

Magnetic sensor systems integrate a sensing element and magnetic field generators to determine their relative position or to measure movement. Typically, the magnetic fields are produced by permanent magnets, which have high intensity but are hard to machine into custom shapes. However, novel solutions using magnetic polymer composites (MPCs) have emerged as field generators due to their low cost, weight and patterning freedom. Here, we present a finite element model developed in COMSOL Multiphysics that allows the design of complex magnetization patterns on these polymer composites, taking into account the geometries of the parts and the magnetic properties of the materials employed. The model, together with the characterization protocol of the materials, has proved to be capable of predicting the magnetization of polymer composites at different temperatures. In addition, the model incorporates the properties of the magnets used during the magnetization process, such as the size, shape and magnetization, as well as the properties of the surrounding elements. This new model facilitates the design of new polymeric parts with complex shapes and magnetization patterns that can be employed as field generators in magnetic sensing systems.

4.
Sensors (Basel) ; 22(5)2022 Mar 05.
Article in English | MEDLINE | ID: mdl-35271180

ABSTRACT

Ag-doped WO3 (Ag-WO3) films were deposited on a soda-lime glass substrate via a facile spray pyrolysis technique. The surface roughness of the films varied between 0.6 nm and 4.3 nm, as verified by the Atomic Force Microscopy (AFM) studies. Ammonia (NH3)-sensing measurements of the films were performed for various concentrations at an optimum sensor working temperature of 200 °C. Enrichment of oxygen vacancies confirmed by X-ray Photoelectron Spectroscopy (XPS) in 1% Ag-WO3 enhanced the sensor response from 1.06 to 3.29, approximately 3 times higher than that of undoped WO3. Limit of detection (LOD) up to 500 ppb is achieved for 1% Ag-WO3, substantiating the role of Ag in improving sensor performance.

5.
J Pers Med ; 9(4)2019 Nov 15.
Article in English | MEDLINE | ID: mdl-31731656

ABSTRACT

Microneedles (MNs) have been extensively explored in the literature as a means to deliver drugs in the skin, surpassing the stratum corneum permeability barrier. MNs are potentially easy to produce and may allow the self-administration of drugs without causing pain or bleeding. More recently, MNs have been investigated to collect/assess the interstitial fluid in order to monitor or detect specific biomarkers. The integration of these two concepts in closed-loop devices holds the promise of automated and minimally invasive disease detection/monitoring and therapy. These assure low invasiveness and, importantly, open a window of opportunity for the application of population-specific and personalised therapies.

6.
Rev Sci Instrum ; 89(5): 053302, 2018 May.
Article in English | MEDLINE | ID: mdl-29864834

ABSTRACT

Recently, we presented a new approach for a compact radio-frequency (RF) accelerator structure and demonstrated the functionality of the individual components: acceleration units and focusing elements. In this paper, we combine these units to form a working accelerator structure: a matching section between the ion source extraction grids and the RF-acceleration unit and electrostatic focusing quadrupoles between successive acceleration units. The matching section consists of six electrostatic quadrupoles (ESQs) fabricated using 3D-printing techniques. The matching section enables us to capture more beam current and to match the beam envelope to conditions for stable transport in an acceleration lattice. We present data from an integrated accelerator consisting of the source, matching section, and an ESQ doublet sandwiched between two RF-acceleration units.

7.
Rev Sci Instrum ; 88(6): 063304, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28667999

ABSTRACT

A new approach for a compact radio-frequency (RF) accelerator structure is presented. The new accelerator architecture is based on the Multiple Electrostatic Quadrupole Array Linear Accelerator (MEQALAC) structure that was first developed in the 1980s. The MEQALAC utilized RF resonators producing the accelerating fields and providing for higher beam currents through parallel beamlets focused using arrays of electrostatic quadrupoles (ESQs). While the early work obtained ESQs with lateral dimensions on the order of a few centimeters, using a printed circuit board (PCB), we reduce the characteristic dimension to the millimeter regime, while massively scaling up the potential number of parallel beamlets. Using Microelectromechanical systems scalable fabrication approaches, we are working on further reducing the characteristic dimension to the sub-millimeter regime. The technology is based on RF-acceleration components and ESQs implemented in the PCB or silicon wafers where each beamlet passes through beam apertures in the wafer. The complete accelerator is then assembled by stacking these wafers. This approach has the potential for fast and inexpensive batch fabrication of the components and flexibility in system design for application specific beam energies and currents. For prototyping the accelerator architecture, the components have been fabricated using the PCB. In this paper, we present proof of concept results of the principal components using the PCB: RF acceleration and ESQ focusing. Ongoing developments on implementing components in silicon and scaling of the accelerator technology to high currents and beam energies are discussed.

8.
Rev Sci Instrum ; 88(1): 015102, 2017 Jan.
Article in English | MEDLINE | ID: mdl-28147679

ABSTRACT

Micropump technology has evolved significantly in the last two decades and is finding a variety of applications ranging from µTAS (micro Total Analysis System) to drug delivery. However, the application area of the micropump is limited owing to: simple pumping mechanism, ease of handling, controlled (microliter to milliliter) delivery, continuous delivery, and accuracy in flow rate. Here, the author presents the design, development, characterization, and precision flow controlling of a DC-motor driven peristaltic pump for controlled drug delivery application. All the micropump components were fabricated using the conventional fabrication technique. The volume flow variation of the pump has been characterized for different viscous fluids. The change in volume flow due to change in back pressure has been presented in detail. The fail-safe mode operation of the pump has been tested and leak rate was measured (∼0.14% leak for an inlet pressure of 140 kPa) for different inlet pressures. The precision volume flow of the pump has been achieved by measuring the pinch cam position and load current. The accuracy in the volume flow has been measured after 300 rotations. Finally, the complete system has been integrated with the necessary electronics and an android application has been developed for the self-administration of bolus and basal delivery of insulin.


Subject(s)
Drug Delivery Systems/instrumentation , Infusion Pumps , Microfluidics , Drug Delivery Systems/methods , Equipment Design
9.
Rev Sci Instrum ; 86(11): 115113, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26628178

ABSTRACT

Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressure leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory.

SELECTION OF CITATIONS
SEARCH DETAIL
...