Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Med ; 11(24)2022 Dec 14.
Article in English | MEDLINE | ID: mdl-36556040

ABSTRACT

Introduction: Radiation exposure is a frequent drawback of spinal surgery, even if X-ray guidance plays a pivotal role in improving the accuracy and safety of spinal procedures. Consequently, radiation protection is essential to reduce potential negative biological effects. The aim of this study was to evaluate patients' radiation exposure, the radiation dose emission during fluoroscopy-guided ozone chemonucleolysis (OCN), and the potential role of patient characteristics. Methods: The radiation dose emission reports were retrospectively evaluated in patients who underwent single-level OCN for lumbar disc herniation. A generalized linear model (GLM) with a gamma distribution and log link function was used to assess the association between radiation emission and patients' characteristics such as age, sex, BMI, level of disc herniation, disc height, and site of disc herniation. Results: Two hundred and forty OCN cases were analyzed. A safe and low level of radiation exposure was registered during OCN. The median fluoroscopy time for OCN was 26.3 (19.4−35.9) seconds, the median radiation emission dose was 19.3 (13.2−27.3) mGy, and he median kerma area product (KAP) was 0.46 (0.33−0.68) mGy ⋅ m2. The resulting KAP values were highly dependent on patient variables. In particular, sex, obesity, and residual disc height < 50% significantly increased the measured KAP, while levels of disc herniations other than L5-S1 reduced the KAP values. Conclusions: The radiation exposure during OCN is low and quite similar to a simple discography. However, patient characteristics are significantly related to radiation exposure and should be carefully evaluated before planning OCN.

2.
Med Phys ; 45(4): 1684-1698, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29383733

ABSTRACT

PURPOSE: To investigate the clinical implication of performing pre-treatment dosimetry for 90 Y-microspheres liver radioembolization on 99m Tc-MAA SPECT images reconstructed without attenuation or scatter correction and quantified with the patient relative calibration methodology. METHODS: Twenty-five patients treated with SIR-Spheres® at Istituto Europeo di Oncologia and 31 patients treated with TheraSphere® at Istituto Nazionale Tumori were considered. For each acquired 99m Tc-MAA SPECT, four reconstructions were performed: with attenuation and scatter correction (AC_SC), only attenuation (AC_NoSC), only scatter (NoAC_SC) and without corrections (NoAC_NoSC). Absorbed dose maps were calculated from the activity maps, quantified applying the patient relative calibration to the SPECT images. Whole Liver (WL) and Tumor (T) regions were drawn on CT images. Injected Liver (IL) region was defined including the voxels receiving absorbed dose >3.8 Gy/GBq. Whole Healthy Liver (WHL) and Healthy Injected Liver (HIL) regions were obtained as WHL = WL - T and HIL = IL - T. Average absorbed dose to WHL and HIL were calculated, and the injection activity was derived following each Institute's procedure. The values obtained from AC_NoSC, NoAC_SC and NoAC_NoSC images were compared to the reference value suggested by AC_SC images using Bland-Altman analysis and Wilcoxon paired test (5% significance threshold). Absorbed-dose maps were compared to the reference map (AC_SC) in global terms using the Voxel Normalized Mean Square Error (%VNMSE), and at voxel level by calculating for each voxel the normalized difference with the reference value. The uncertainty affecting absorbed dose at voxel level was accounted for in the comparison; to this purpose, the voxel counts fluctuation due to Poisson and reconstruction noise was estimated from SPECT images of a water phantom acquired and reconstructed as patient images. RESULTS: NoAC_SC images lead to activity prescriptions not significantly different from the reference AC_SC images; the individual differences (<0.1 GBq for all IEO patients, <0.6 GBq for all but one INT patients) were comparable to the uncertainty affecting activity measurement. AC_NoSC and NoAC_NoSC images, instead, yielded significantly different activity prescriptions and wider 95% confidence intervals in the Bland-Altman analysis. Concerning the absorbed dose map, AC_NoSC images had the smallest %VNMSE value and the highest fraction of voxels differing less than 2 standard deviations from AC_SC. CONCLUSIONS: The patient relative calibration methodology can compensate for the missing attenuation correction when performing healthy liver pre-treatment dosimetry: safe treatments can be planned even on NoAC_SC images, suggesting activities comparable to AC_SC images. Scatter correction is recommended due to its heavy impact on healthy liver dosimetry.


Subject(s)
Embolization, Therapeutic , Image Processing, Computer-Assisted , Liver/diagnostic imaging , Liver/radiation effects , Scattering, Radiation , Technetium Tc 99m Aggregated Albumin , Tomography, Emission-Computed, Single-Photon , Adult , Calibration , Female , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/therapy , Male , Middle Aged , Monte Carlo Method , Phantoms, Imaging , Radiometry , Retrospective Studies , Signal-To-Noise Ratio , Uncertainty
3.
Saf Health Work ; 4(2): 95-9, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23961332

ABSTRACT

BACKGROUND: Work-related stress is one of the major causes of occupational ill health. In line with the regulatory framework on occupational health and safety (OSH), adequate models for assessing and managing risk need to be identified so as to minimize the impact of this stress not only on workers' health, but also on productivity. METHODS: After close analysis of the Italian and European reference regulatory framework and work-related stress assessment and management models used in some European countries, we adopted the UK Health and Safety Executive's (HSE) Management Standards (MS) approach, adapting it to the Italian context in order to provide a suitable methodological proposal for Italy. RESULTS: We have developed a work-related stress risk assessment strategy, meeting regulatory requirements, now available on a specific web platform that includes software, tutorials, and other tools to assist companies in their assessments. CONCLUSION: This methodological proposal is new on the Italian work-related stress risk assessment scene. Besides providing an evaluation approach using scientifically validated instruments, it ensures the active participation of occupational health professionals in each company. The assessment tools provided enable companies not only to comply with the law, but also to contribute to a database for monitoring and assessment and give access to a reserved area for data analysis and comparisons.

SELECTION OF CITATIONS
SEARCH DETAIL
...