Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Analyst ; 134(3): 472-7, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19238282

ABSTRACT

This paper describes a microfluidic device fabricated in poly(dimethylsiloxane) that was employed to perform amperometric quantifications using on-chip calibration curves and on-chip standard addition methods. This device integrated a network of Au electrodes within a microfluidic structure designed for automatic preparation of a series of solutions containing an electroactive molecule at a concentration linearly decreasing. This device was first characterized by fluorescence microscopy and then evaluated with a model electroactive molecule such as Fe(CN(6))(4-). Operating a quantification in this microfluidic parallel approach rather than in batch mode allows a reduced analysis time to be achieved. Moreover, the microfluidic approach is compatible with the on-chip calibration of sensors simultaneously to the analysis, therefore preventing problems due to sensor response deviation with time. When using the on-chip calibration and on-chip standard addition method, we reached concentration estimation better than 5%. We also demonstrated that compared to the calibration curve approach, the standard addition mode is less complex to operate. Indeed, in this case, it is not necessary to take into account flow rate discrepancies as in the calibration approach.

2.
Anal Chem ; 79(13): 4879-86, 2007 Jul 01.
Article in English | MEDLINE | ID: mdl-17523594

ABSTRACT

The low but known risk of bacterial contamination has emerged as the greatest residual threat of transfusion-transmitted diseases. Label-free detection of a bacterial model, Escherichia coli, is performed using nonfaradic electrochemical impedance spectroscopy (EIS). Biotinylated polyclonal anti-E. coli is linked to a mixed self-assembled monolayer (SAM) on a gold electrode through a strong biotin-neutravidin interaction. The binding of one antibody molecule for 3.6 neutravidin molecules is determined using the surface plasmon resonance (SPR). The detection limit of E. coli found by SPR is 10(7) cfu/mL. After modeling the impedance Nyquist plot of E. coli/anti-E. coli/mixed SAM/gold electrode for increasing concentrations of E. coli (whole bacteria or lysed bacteria), the main parameter that is modified is the polarization resistance RP. A sigmoid variation of RP is observed when the log concentration of bacteria (whole or lysed) increases. A concentration of 10 cfu/mL whole bacteria is detected by EIS measurements while 103 cfu/mL is detected for lysed E. coli.


Subject(s)
Bacteria/isolation & purification , Biosensing Techniques/methods , Gold/chemistry , Spectrum Analysis/methods , Surface Plasmon Resonance/methods , Antibodies, Bacterial/immunology , Avidin/chemistry , Bacteria/immunology , Biosensing Techniques/instrumentation , Biotin/chemistry , Electric Impedance , Electrodes , Equipment Design , Escherichia coli O157/immunology , Escherichia coli O157/isolation & purification , Immunoassay , Immunoblotting , Sensitivity and Specificity , Spectrum Analysis/instrumentation , Surface Plasmon Resonance/instrumentation
3.
Biosens Bioelectron ; 22(11): 2682-8, 2007 May 15.
Article in English | MEDLINE | ID: mdl-17161943

ABSTRACT

An electrochemical biosensor based on a glassy carbon (GC) electrode chemically modified with the perfluorinated cation-exchange polymer Nafion and methyl viologen (MV) is described. The enzyme was immobilized by cross-linking with glutaraldehyde in the presence of bovine serum albumin (BSA), methyl viologen and Nafion. Operating variables such as the enzyme/BSA ratio, cross-linking time in glutaraldehyde vapor, methyl viologen and Nafion percentages were investigated with regard to their influence on the biosensor sensitivity by using glucose oxidase as the enzyme model due to its high stability and low cost. The glutamate biosensor was elaborated by using optimized parameters and its electrochemical properties were investigated by cyclic voltammetry, amperometry and by electrochemical impedance spectroscopy. The glutamate biosensor shows a detection limit of 20 microM and a linear range extended to 0.75 mM. Its selectivity was tested with 15 different amino acids, each with a concentration of 20 microM, 25 microM acetaminophen, 20 microM uric acid and 200 microM ascorbic acid. No amperometric response was observed for the interfering species. This good selectivity allows glutamate detection in biological media without previous separation of the analyte.


Subject(s)
Biosensing Techniques/instrumentation , Carbon/chemistry , Electrochemistry/instrumentation , Fluorocarbon Polymers/chemistry , Glutamic Acid/chemistry , Microelectrodes , Paraquat/chemistry , Biosensing Techniques/methods , Coated Materials, Biocompatible/chemistry , Electric Impedance , Electrochemistry/methods , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity
4.
Anal Bioanal Chem ; 383(5): 839-47, 2005 Nov.
Article in English | MEDLINE | ID: mdl-16215756

ABSTRACT

Stripping analysis has been widely recognised as a powerful tool in trace metal analysis. Its remarkable sensitivity is attributed to the combination of a preconcentration step coupled with pulse measurements that generate an extremely high signal-to-background ratio. Mercury-based electrodes have traditionally been used to achieve high reproducibility and sensitivity in the stripping technique. Because of the toxicity of mercury, however, new alternative electrode materials are highly desired, particularly for on-site monitoring. Use of thin films of bismuth deposited on platinum or glassy-carbon substrates has recently been proposed as a possible alternative to mercury--bismuth is "environmentally friendly", of low toxicity, and is in widespread pharmaceutical use. In this paper the preparation of economic bismuth-film microelectrodes by electrodeposition on a copper substrate and their application to heavy metal analysis are described. Bismuth-film electrodes were prepared by potentiostatic electrodeposition. Optimum conditions for chemical and electrochemical deposition to obtain an adherent, reproducible, and robust deposit were determined. The suitability of such microelectrodes for analysis of heavy metals was evaluated by anodic stripping voltammetry of cadmium. The analytical performance of bismuth-film electrodes for anodic stripping voltammetry of heavy metals was evaluated for non-deaerated solutions containing Cd2+, Pb2+, and Zn2+ ions. Well-defined peaks with low background current were obtained by use of differential pulse voltammetry. Linear calibration plots were obtained for Cd2+ in acidified tap water at concentrations ranging from 2 x 10(-8) to 1 x 10(-7) mol L(-1) and from 1 x 10(-7) to 1 x 10(-6) mol L(-1) with relative standard deviations of 5% (n = 15) at the 1 x 10(-7) mol L(-1) level. The method was then successfully used to monitor the Cd2+ content of plant extracts and validated by polarographic and ICP-MS measurements. These results open the possibility of using bismuth-coated copper electrodes as an alternative to mercury-based electrodes for analysis of heavy metals. The main problem remaining, which prevents on-site monitoring of heavy metals, is the need to use slightly acidic media, because formation of bismuth hydroxide on the film surface above pH 4.3 leads to non-reproducible measurements. Further experiments will be performed to discover whether electrode conditioning can be used to enable reproducible measurement in on-site monitoring of cadmium in natural waters. Moreover, further study should be conducted to evaluate the potential of BiFE for analysis of several pollutants of interest that are usually determined electrochemically by using mercury-based electrodes.


Subject(s)
Biosensing Techniques/methods , Bismuth/chemistry , Electrochemistry/methods , Metals, Heavy/analysis , Microelectrodes , Plant Extracts/analysis , Trace Elements/analysis , Biosensing Techniques/economics , Biosensing Techniques/instrumentation , Coated Materials, Biocompatible/chemistry , Electrochemistry/economics , Electrochemistry/instrumentation , Environmental Pollutants/analysis , Equipment Design , Equipment Failure Analysis , Membranes, Artificial , Metals, Heavy/chemistry , Miniaturization , Plant Extracts/chemistry , Reproducibility of Results , Sensitivity and Specificity , Trace Elements/chemistry
5.
Anal Bioanal Chem ; 380(3): 551-5, 2004 Oct.
Article in English | MEDLINE | ID: mdl-15338096

ABSTRACT

The contamination of drinking water and industrial wastewaters is a critical environmental problem. The nitrophenol, dinitrophenol, cadmium, and lead contaminants are classified as hazardous compounds. Their rapid determination may be obtained using differential pulse polarography with concentrated electrolyte. CaCl2, which is very soluble to levels exceeding 5 mol l(-1), allows separation of coalescent peaks at 0.1 mol l(-1). A systematic study undertaken from 0.1 to 5 mol l(-1) shows good separation of lead and cadmium from the organic compounds, and optimization of the electrolyte concentration according to the objective is described. Preconcentration of real samples is necessary because pollution levels are usually very low.


Subject(s)
Cadmium/chemistry , Calcium Chloride/chemistry , Electrolytes/chemistry , Lead/chemistry , Nitrophenols/analysis , Phosphatidylserines/chemistry , Water Pollutants/analysis , Dinitrophenols/analysis , Environmental Monitoring , Polarography , Sensitivity and Specificity , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...