Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Mater Lett ; 5(9): 2508-2517, 2023 Sep 04.
Article in English | MEDLINE | ID: mdl-37680546

ABSTRACT

Delivering heat in vivo could enhance a wide range of biomedical therapeutic and diagnostic technologies, including long-term drug delivery devices and cancer treatments. To date, providing thermal energy is highly power-intensive, rendering it oftentimes inaccessible outside of clinical settings. We developed an in vivo heating method based on the exothermic reaction between liquid-metal-activated aluminum and water. After establishing a method for consistent activation, we characterized the heat generation capabilities with thermal imaging and heat flux measurements. We then demonstrated one application of this reaction: to thermally actuate a gastric resident device made from a shape-memory alloy called Nitinol. Finally, we highlight the advantages and future directions for leveraging this novel in situ heat generation method beyond the showcased example.

2.
J Clin Med ; 12(4)2023 Feb 04.
Article in English | MEDLINE | ID: mdl-36835787

ABSTRACT

BACKGROUND AND OBJECTIVE: To determine the association between point-of-care-ultrasonography (POCUS)-measured sarcopenia and grip strength, as well as the history of prior-year falls among older adults admitted to the emergency department observation unit (EDOU). MATERIALS AND METHODS: This cross-sectional observational study was conducted over 8 months at a large urban teaching hospital. A consecutive sample of patients who were 65 years or older and admitted to the EDOU were enrolled in the study. Using standardized techniques, trained research assistants and co-investigators measured patients' biceps brachii and thigh quadriceps muscles via a linear transducer. Grip strength was measured using a Jamar Hydraulic Hand Dynamometer. Participants were surveyed regarding their history of falls in the prior year. Logistic regression analyses assessed the relationship of sarcopenia and grip strength to a history of falls (the primary outcome). RESULTS: Among 199 participants (55% female), 46% reported falling in the prior year. The median biceps thickness was 2.22 cm with an Interquartile range [IQR] of 1.87-2.74, and the median thigh muscle thickness was 2.91 cm with an IQR of 2.40-3.49. A univariate logistic regression analysis demonstrated a correlation between higher thigh muscle thickness, normal grip strength, and history of prior-year falling, with an odds ratio [OR] of 0.67 (95% conference interval [95%CI] 0.47-0.95) and an OR of 0.51 (95%CI 0.29-0.91), respectively. In multivariate logistic regression, only higher thigh muscle thickness was correlated with a history of prior-year falls, with an OR of 0.59 (95% CI 0.38-0.91). CONCLUSIONS: POCUS-measured thigh muscle thickness has the potential to identify patients who have fallen and thus are at high risk for future falls.

3.
Adv Mater Technol ; 6(6)2021 Jun.
Article in English | MEDLINE | ID: mdl-34179344

ABSTRACT

Injectable 3D cell scaffolds possessing both electrical conductivity and native tissue-level softness would provide a platform to leverage electric fields to manipulate stem cell behavior. Granular hydrogels, which combine jamming-induced elasticity with repeatable injectability, are versatile materials to easily encapsulate cells to form injectable 3D niches. In this work, we demonstrate that electrically conductive granular hydrogels can be fabricated via a simple method involving fragmentation of a bulk hydrogel made from the conducting polymer PEDOT:PSS. These granular conductors exhibit excellent shear-thinning and self-healing behavior, as well as record-high electrical conductivity for an injectable 3D scaffold material (~10 S m-1). Their granular microstructure also enables them to easily encapsulate induced pluripotent stem cell (iPSC)-derived neural progenitor cells, which were viable for at least 5 days within the injectable gel matrices. Finally, we demonstrate gel biocompatibility with minimal observed inflammatory response when injected into a rodent brain.

4.
Adv Healthc Mater ; 10(17): e2001916, 2021 09.
Article in English | MEDLINE | ID: mdl-33899347

ABSTRACT

Owing to their excellent mechanical flexibility, mixed-conducting electrical property, and extraordinary chemical turnability, conjugated polymers have been demonstrated to be an ideal bioelectronic interface to deliver therapeutic effect in many different chronic diseases. This review article summarizes the latest advances in implantable electronics using conjugated polymers as electroactive materials and identifies remaining challenges and opportunities for developing electronic medicine. Examples of conjugated polymer-based bioelectronic devices are selectively reviewed in human clinical studies or animal studies with the potential for clinical adoption. The unique properties of conjugated polymers are highlighted and exemplified as potential solutions to address the specific challenges in electronic medicine.


Subject(s)
Electronics , Polymers , Animals , Electronics, Medical , Humans
5.
Anim Reprod Sci ; 226: 106697, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33482475

ABSTRACT

Resveratrol, a potent antioxidant, can be an alternative semen extender constituent to protect spermatozoa against reactive oxygen species (ROS); however, effects on sperm quality post-thawing and sperm function is not well understood. This study, therefore, was conducted to investigate effects of resveratrol supplementation to semen extender on sperm quality post-thawing. Bull semen was cryopreserved using extenders not supplemented or supplemented with 0.05, 0.1, or 1 mM resveratrol. Supplementation of extender with resveratrol at 0.05 mM resulted in greater (P < 0.05) sperm progressive motility, average path velocity, straight linear velocity, linearity and straightness when compared with no or 1 mM supplementations. Furthermore, effects of 0.05 mM resveratrol supplementations on plasma membrane and acrosome integrity and sperm fertilization capacity using in vitro procedures were investigated. Supplementation of semen extender with resveratrol resulted in a greater (P < 0.05) proportion of frozen-thawed spermatozoa with an intact acrosome and plasma membrane. Results from in vitro fertilization studies indicated there were no differences (P> 0.05) when there was no supplementation or supplementation with 0.05 mM resveratrol on embryo development to the cleavage and blastocyst stages. In conclusion, addition of resveratrol to bull semen extender resulted in greater sperm quality post-thawing in a dose-dependent manner, with values for variables related to sperm quality being greater when there was resveratrol supplementation at the 0.05 mM concentration. Proportion of embryo developing to the cleavage and blastocyst stages after in vitro fertilization was not affected by resveratrol supplementation to semen extenders.


Subject(s)
Cattle , Cryopreservation/veterinary , Resveratrol/pharmacology , Semen Analysis/veterinary , Semen Preservation/veterinary , Animals , Antioxidants/administration & dosage , Antioxidants/pharmacology , Dose-Response Relationship, Drug , Fertilization in Vitro/veterinary , Male , Resveratrol/administration & dosage
6.
ACS Cent Sci ; 5(11): 1884-1891, 2019 Nov 27.
Article in English | MEDLINE | ID: mdl-31807690

ABSTRACT

The next materials challenge in organic stretchable electronics is the development of a fully degradable semiconductor that maintains stable electrical performance under strain. Herein, we decouple the design of stretchability and transience by harmonizing polymer physics principles and molecular design in order to demonstrate for the first time a material that simultaneously possesses three disparate attributes: semiconductivity, intrinsic stretchability, and full degradability. We show that we can design acid-labile semiconducting polymers to appropriately phase segregate within a biodegradable elastomer, yielding semiconducting nanofibers that concurrently enable controlled transience and strain-independent transistor mobilities. Along with the future development of suitable conductors and device integration advances, we anticipate that these materials could be used to build fully biodegradable diagnostic or therapeutic devices that reside inside the body temporarily, or environmental monitors that are placed in the field and break down when they are no longer needed. This fully degradable semiconductor represents a promising advance toward developing multifunctional materials for skin-inspired electronic devices that can address previously inaccessible challenges and in turn create new technologies.

7.
Reproduction ; 158(4): 313-322, 2019 10.
Article in English | MEDLINE | ID: mdl-31426029

ABSTRACT

Heat stress compromises bovine oocyte developmental competence, but the effects of high temperature during oocyte maturation on embryo chromatin organization is unknown. In this study bovine oocytes were exposed to heat shock (41°C) for 12 h during in vitro maturation and then submitted to in vitro fertilization. The heat shock did not affect (P > 0.05) the cleavage but reduced (P < 0.01) the blastocyst rate on Day 7 and Day 8. No effect (P > 0.05) on total cell number was found, but the heat shock increased (P < 0.05) the proportion of apoptotic cells in blastocysts at Day 8. Immunofluorescence analysis of H3K9me3 and HP1 was performed in embryos at 52 h post in vitro fertilization. An accumulation of H3K9me3 in the nuclei of embryos derived from heat-shocked oocytes at four-cell and eight-cell stages was found. Also, a non-expected higher proportion (P < 0.05) of four-cell stage embryos displaying nuclei with increased HP1 fluorescence was observed, suggesting an abnormal chromatin compaction in embryos from heat-shocked oocytes. Embryos at eight-cell stage derived from heat-shocked oocytes displayed lower (P < 0.05) relative amount of HSP40 transcripts than control ones. In conclusion, heat shock before fertilization has an effect on embryo chromatin, influencing the accumulation of H3K9me3 and HP1 in early embryos as well as further development.


Subject(s)
Blastocyst/pathology , Chromatin/chemistry , Embryo, Mammalian/pathology , Heat-Shock Response , In Vitro Oocyte Maturation Techniques/methods , Oocytes/pathology , Oogenesis , Animals , Apoptosis , Blastocyst/metabolism , Cattle , Chromatin/genetics , Chromatin/metabolism , Embryo, Mammalian/metabolism , Embryonic Development , Female , Fertilization in Vitro , Gene Expression Regulation, Developmental , Oocytes/metabolism
8.
Adv Mater ; 31(39): e1902869, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31414520

ABSTRACT

Due to their high water content and macroscopic connectivity, hydrogels made from the conducting polymer PEDOT:PSS are a promising platform from which to fabricate a wide range of porous conductive materials that are increasingly of interest in applications as varied as bioelectronics, regenerative medicine, and energy storage. Despite the promising properties of PEDOT:PSS-based porous materials, the ability to pattern PEDOT:PSS hydrogels is still required to enable their integration with multifunctional and multichannel electronic devices. In this work, a novel electrochemical gelation ("electrogelation") method is presented for rapidly patterning PEDOT:PSS hydrogels on any conductive template, including curved and 3D surfaces. High spatial resolution is achieved through use of a sacrificial metal layer to generate the hydrogel pattern, thereby enabling high-performance conducting hydrogels and aerogels with desirable material properties to be introduced into increasingly complex device architectures.

9.
Nat Mater ; 18(6): 594-601, 2019 06.
Article in English | MEDLINE | ID: mdl-30988452

ABSTRACT

Stretchable semiconducting polymers have been developed as a key component to enable skin-like wearable electronics, but their electrical performance must be improved to enable more advanced functionalities. Here, we report a solution processing approach that can achieve multi-scale ordering and alignment of conjugated polymers in stretchable semiconductors to substantially improve their charge carrier mobility. Using solution shearing with a patterned microtrench coating blade, macroscale alignment of conjugated-polymer nanostructures was achieved along the charge transport direction. In conjunction, the nanoscale spatial confinement aligns chain conformation and promotes short-range π-π ordering, substantially reducing the energetic barrier for charge carrier transport. As a result, the mobilities of stretchable conjugated-polymer films have been enhanced up to threefold and maintained under a strain up to 100%. This method may also serve as the basis for large-area manufacturing of stretchable semiconducting films, as demonstrated by the roll-to-roll coating of metre-scale films.

SELECTION OF CITATIONS
SEARCH DETAIL
...