Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
2.
Catheter Cardiovasc Interv ; 97(1): E79-E87, 2021 01 01.
Article in English | MEDLINE | ID: mdl-32259389

ABSTRACT

OBJECTIVES: We sought to determine hemodynamic effects of aortic paravalvular leak (PVL) and predictors of clinical outcomes after aortic PVL closure. BACKGROUND: The significance of hemodynamic alterations in PVL and relation to severity, procedural success of percutaneous closure and clinical outcomes have not been defined. METHODS: Patients undergoing percutaneous PVL closure between July 21, 2004 and September 10, 2018 were included. PVL severity was assessed by echocardiography and aortic angiography. Hemodynamics were assessed by intra-arterial pressure tracings before and after PVL closure. The primary outcome was a composite of mortality, redo aortic valve replacement (AVR) and redo PVL closure. RESULTS: One hundred and seventeen patients (mean age 70.3 ± 14.9 years, 79% surgical and 21% transcatheter prostheses) underwent PVL closure with 94% technical success. PVL was moderate or greater in 106 (91%) at baseline and 11 (11%) post-procedure. Diastolic BP for those with moderate or greater PVL was lower than for those with less PVL (50.3 ± 11.7 vs. 56.5 ± 12.4 mmHg, p < .001). Pulse pressure was similar between these groups (69.9 ± 20.3 vs. 67.4 ± 21.2 mmHg, p = .39). 35 patients (34%) had 40 events during a mean follow-up of 1.6 ± 1.9 years (23 deaths, 12 redo AVR, and five redo PVL closures). In a multivariate model, final diastolic BP <47 mmHg (HR 3.27 [1.45-7.36], p = .007) was a significant predictor of the composite endpoint. CONCLUSIONS: Diastolic BP was significantly associated with aortic PVL severity and clinical outcomes after PVL closure. In contrast, pulse pressure did not correlate with PVL severity or outcomes. These findings have implications for clinical management of patients with aortic PVL.


Subject(s)
Aortic Valve Insufficiency , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Blood Pressure , Heart Valve Prosthesis Implantation/adverse effects , Humans , Retrospective Studies , Treatment Outcome
3.
Catheter Cardiovasc Interv ; 97(2): E249-E252, 2021 02 01.
Article in English | MEDLINE | ID: mdl-32383284

ABSTRACT

A 48-year-old woman with a past medical history of migraines and hyperlipidemia presented due to severe retrosternal chest pain with no other associated signs or symptoms. The patient was hemodynamically stable and was found to have an elevated troponin with electrocardiogram showing no ischemic changes. Computed tomography of the coronary arteries showed a left dominant system with dissection extending from the mid-to-distal left anterior descending (LAD) artery. The patient was subsequently discharged on medical therapy but returned 3 days later due to worsening chest pain. Electrocardiogram revealed inferior and anteroseptal ST segment changes with peak troponin of 14.9 ng/ml (reference range <0.80 ng/ml). Coronavirus disease 2019 (COVID-19) nasopharyngeal swab was performed prior to urgent coronary angiogram. Coronary angiogram was performed with full personal protective equipment for respiratory and droplet precautions due to pending COVID-19 testing results. Angiogram revealed spontaneous coronary artery dissection (SCAD) extending from the ostium of the LAD to the distal vessel. COVID-19 testing returned positive while in intensive care unit. The patient was not a percutaneous coronary intervention candidate due to the extent of the dissection and was not a surgical candidate due to a lack of graftable target and medical management was continued. To our knowledge, this case is the first in which SCAD has been reported in the LAD in a patient with COVID-19 with no other symptoms of respiratory illness or symptoms classically associated with the novel coronavirus. SCAD should be considered on the differential as one of the various cardiac manifestations of COVID-19 infection.


Subject(s)
COVID-19/complications , COVID-19/diagnosis , Coronary Vessel Anomalies/diagnosis , Coronary Vessel Anomalies/virology , Vascular Diseases/congenital , COVID-19/therapy , Coronary Angiography , Coronary Vessel Anomalies/therapy , Electrocardiography , Female , Humans , Middle Aged , Vascular Diseases/diagnosis , Vascular Diseases/therapy , Vascular Diseases/virology
SELECTION OF CITATIONS
SEARCH DETAIL
...