Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50
Filter
1.
Biomed Opt Express ; 15(4): 2308-2327, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38633081

ABSTRACT

Pulse oximetry represents a ubiquitous clinical application of optics in modern medicine. Recent studies have raised concerns regarding the potential impact of confounders, such as variable skin pigmentation and perfusion, on blood oxygen saturation measurement accuracy in pulse oximeters. Tissue-mimicking phantom testing offers a low-cost, well-controlled solution for characterizing device performance and studying potential error sources, which may thus reduce the need for costly in vivo trials. The purpose of this study was to develop realistic phantom-based test methods for pulse oximetry. Material optical and mechanical properties were reviewed, selected, and tuned for optimal biological relevance, e.g., oxygenated tissue absorption and scattering, strength, elasticity, hardness, and other parameters representing the human finger's geometry and composition, such as blood vessel size and distribution, and perfusion. Relevant anatomical and physiological properties are summarized and implemented toward the creation of a preliminary finger phantom. To create a preliminary finger phantom, we synthesized a high-compliance silicone matrix with scatterers for embedding flexible tubing and investigated the addition of these scatterers to novel 3D printing resins for optical property control without altering mechanical stability, streamlining the production of phantoms with biologically relevant characteristics. Phantom utility was demonstrated by applying dynamic, pressure waveforms to produce tube volume change and resultant photoplethysmography (PPG) signals. 3D printed phantoms achieved more biologically relevant conditions compared to molded phantoms. These preliminary results indicate that the phantoms show strong potential to be developed into tools for evaluating pulse oximetry performance. Gaps, recommendations, and strategies are presented for continued phantom development.

2.
Biomed Opt Express ; 14(11): 5735-5748, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-38021140

ABSTRACT

Recent reports have raised concerns of potential racial disparities in performance of optical oximetry technologies. To investigate how variable epidermal melanin content affects performance of photoacoustic imaging (PAI) devices, we developed plastisol phantoms combining swappable skin-mimicking layers with a breast phantom containing either India ink or blood adjusted to 50-100% SO2 using sodium dithionite. Increasing skin pigmentation decreased maximum imaging depth by up to 25%, enhanced image clutter, and increased root-mean-square error in SO2 from 8.0 to 17.6% due to signal attenuation and spectral coloring effects. This phantom tool can aid in evaluating PAI device robustness to ensure high performance in all patients.

3.
Photoacoustics ; 32: 100539, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37600964

ABSTRACT

Photoacoustic imaging (PAI), also referred to as optoacoustic imaging, has shown promise in early-stage clinical trials in a range of applications from inflammatory diseases to cancer. While the first PAI systems have recently received regulatory approvals, successful adoption of PAI technology into healthcare systems for clinical decision making must still overcome a range of barriers, from education and training to data acquisition and interpretation. The International Photoacoustic Standardisation Consortium (IPASC) undertook an community exercise in 2022 to identify and understand these barriers, then develop a roadmap of strategic plans to address them. Here, we outline the nature and scope of the barriers that were identified, along with short-, medium- and long-term community efforts required to overcome them, both within and beyond the IPASC group.

4.
Biomed Opt Express ; 13(5): 2909-2928, 2022 May 01.
Article in English | MEDLINE | ID: mdl-35774336

ABSTRACT

Clinical studies have demonstrated that epidermal pigmentation level can affect cerebral oximetry measurements. To evaluate the robustness of these devices, we have developed a phantom-based test method that includes an epidermis-simulating layer with several melanin concentrations and a 3D-printed cerebrovascular module. Measurements were performed with neonatal, pediatric and adult sensors from two commercial oximeters, where neonatal probes had shorter source-detector separation distances. Referenced blood oxygenation levels ranged from 30 to 90%. Cerebral oximeter outputs exhibited a consistent decrease in saturation level with simulated melanin content; this effect was greatest at low saturation levels, producing a change of up to 15%. Dependence on pigmentation was strongest in a neonatal sensor, possibly due to its high reflectivity. Overall, our findings indicate that a modular channel-array phantom approach can provide a practical tool for assessing the impact of skin pigmentation on cerebral oximeter performance and that modifications to algorithms and/or instrumentation may be needed to mitigate pigmentation bias.

5.
Photoacoustics ; 26: 100348, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35360521

ABSTRACT

Standardized phantoms and test methods are needed to accelerate clinical translation of emerging photoacoustic imaging (PAI) devices. Evaluating object detectability in PAI is challenging due to variations in target morphology and artifacts including boundary buildup. Here we introduce breast fat and parenchyma tissue-mimicking materials based on emulsions of silicone oil and ethylene glycol in polyacrylamide hydrogel. 3D-printed molds were used to fabricate solid target inclusions that produced more filled-in appearance than traditional PAI phantoms. Phantoms were used to assess understudied image quality characteristics (IQCs) of three PAI systems. Object detectability was characterized vs. target diameter, absorption coefficient, and depth. Boundary buildup was quantified by target core/boundary ratio, which was higher in transducers with lower center frequency. Target diameter measurement accuracy was also size-dependent and improved with increasing transducer frequency. These phantoms enable evaluation of multiple key IQCs and may support development of comprehensive standardized test methods for PAI devices.

6.
Biomed Opt Express ; 13(3): 1357-1373, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35415004

ABSTRACT

Phantom-based performance test methods are critically needed to support development and clinical translation of emerging photoacoustic microscopy (PAM) devices. While phantoms have been recently developed for macroscopic photoacoustic imaging systems, there is an unmet need for well-characterized tissue-mimicking materials (TMMs) and phantoms suitable for evaluating PAM systems. Our objective was to develop and characterize a suitable dermis-mimicking TMM based on polyacrylamide hydrogels and demonstrate its utility for constructing image quality phantoms. TMM formulations were optically characterized over 400-1100 nm using integrating sphere spectrophotometry and acoustically characterized using a pulse through-transmission method over 8-24 MHz with highly confident extrapolation throughout the usable band of the PAM system. This TMM was used to construct a spatial resolution phantom containing gold nanoparticle point targets and a penetration depth phantom containing slanted tungsten filaments and blood-filled tubes. These phantoms were used to characterize performance of a custom-built PAM system. The TMM was found to be broadly tunable and specific formulations were identified to mimic human dermis at an optical wavelength of 570 nm and acoustic frequencies of 10-50 MHz. Imaging results showed that tungsten filaments yielded 1.1-4.2 times greater apparent maximum imaging depth than blood-filled tubes, which may overestimate real-world performance for vascular imaging applications. Nanoparticles were detectable only to depths of 120-200 µm, which may be due to the relatively weaker absorption of single nanoparticles vs. larger targets containing high concentration of hemoglobin. The developed TMMs and phantoms are useful tools to support PAM device characterization and optimization, streamline regulatory decision-making, and accelerate clinical translation.

7.
Photoacoustics ; 26: 100339, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35287304

ABSTRACT

Photoacoustic imaging (PAI) is an emerging modality that has shown promise for improving patient management in a range of applications. Unfortunately, the current lack of uniformity in PAI data formats compromises inter-user data exchange and comparison, which impedes: technological progress; effective research collaboration; and efforts to deliver multi-centre clinical trials. To overcome this challenge, the International Photoacoustic Standardisation Consortium (IPASC) has established a data format with a defined consensus metadata structure and developed an open-source software application programming interface (API) to enable conversion from proprietary file formats into the IPASC format. The format is based on Hierarchical Data Format 5 (HDF5) and designed to store photoacoustic raw time series data. Internal quality control mechanisms are included to ensure completeness and consistency of the converted data. By unifying the variety of proprietary data and metadata definitions into a consensus format, IPASC hopes to facilitate the exchange and comparison of PAI data.

8.
J Biomed Opt ; 26(9)2021 09.
Article in English | MEDLINE | ID: mdl-34510850

ABSTRACT

SIGNIFICANCE: Photoacoustic imaging (PAI) is a powerful emerging technology with broad clinical applications, but consensus test methods are needed to standardize performance evaluation and accelerate translation. AIM: To review consensus image quality test methods for mature imaging modalities [ultrasound, magnetic resonance imaging (MRI), x-ray CT, and x-ray mammography], identify best practices in phantom design and testing procedures, and compare against current practices in PAI phantom testing. APPROACH: We reviewed scientific papers, international standards, clinical accreditation guidelines, and professional society recommendations describing medical image quality test methods. Observations are organized by image quality characteristics (IQCs), including spatial resolution, geometric accuracy, imaging depth, uniformity, sensitivity, low-contrast detectability, and artifacts. RESULTS: Consensus documents typically prescribed phantom geometry and material property requirements, as well as specific data acquisition and analysis protocols to optimize test consistency and reproducibility. While these documents considered a wide array of IQCs, reported PAI phantom testing focused heavily on in-plane resolution, depth of visualization, and sensitivity. Understudied IQCs that merit further consideration include out-of-plane resolution, geometric accuracy, uniformity, low-contrast detectability, and co-registration accuracy. CONCLUSIONS: Available medical image quality standards provide a blueprint for establishing consensus best practices for photoacoustic image quality assessment and thus hastening PAI technology advancement, translation, and clinical adoption.


Subject(s)
Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Consensus , Humans , Phantoms, Imaging , Reproducibility of Results
9.
Photoacoustics ; 22: 100245, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33747787

ABSTRACT

As photoacoustic imaging (PAI) begins to mature and undergo clinical translation, there is a need for well-validated, standardized performance test methods to support device development, quality control, and regulatory evaluation. Despite recent progress, current PAI phantoms may not adequately replicate tissue light and sound transport over the full range of optical wavelengths and acoustic frequencies employed by reported PAI devices. Here we introduce polyacrylamide (PAA) hydrogel as a candidate material for fabricating stable phantoms with well-characterized optical and acoustic properties that are biologically relevant over a broad range of system design parameters. We evaluated suitability of PAA phantoms for conducting image quality assessment of three PAI systems with substantially different operating parameters including two commercial systems and a custom system. Imaging results indicated that appropriately tuned PAA phantoms are useful tools for assessing and comparing PAI system image quality. These phantoms may also facilitate future standardization of performance test methodology.

10.
Br J Clin Psychol ; 59(3): 424-438, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32478862

ABSTRACT

OBJECTIVE: Acceptance and commitment therapy, mindfulness-based cognitive therapy, and problem-solving therapy are types of cognitive-behavioural therapy (CBT) group that improve physical and mental health in chronic pain or cancer. However, dropout is high due to group demands alongside physical impairments. Motivational interviewing (MI) is a well-evidenced means of enhancing treatment adherence. Few studies have investigated MI as an adjunct to CBT in cancer or chronic pain, and none have established the minimum MI duration required for adherence improvement. This study evaluated minimal-duration MI to improve adherence in three CBT group types for cancer and chronic pain. METHODS: In a cohort study of 99 cancer and chronic pain patients, 47 were given a 10- to 15-min structured MI telephone intervention (MI-call) after the first session. The remaining 52 received a CBT group without MI (no-MI). RESULTS: Odds of completing group CBTs were five times greater for patients in the MI-call cohort versus no-MI. Effects remained when controlling for age, gender, diagnosis, group type, and baseline quality of life. The MI-call cohort attended one extra session per patient compared to no-MI, controlling for age, gender, and diagnosis. CONCLUSIONS: A brief MI telephone intervention may improve adherence to group CBTs in cancer and chronic pain. PRACTITIONER POINTS: A brief motivational interviewing (MI) telephone intervention may reduce dropout from group cognitive-behavioural therapies (CBTs) for cancer and chronic pain patients when administered after the first group session in routine care. Recipients of this intervention were five times more likely to complete a group CBT programme than those who did not receive it. Therefore, a minimal-dose MI intervention can have clinically important effects on dropout in group CBTs for patients with long-term conditions. It is unclear whether this intervention would also result in greater outcome improvements.


Subject(s)
Acceptance and Commitment Therapy/methods , Chronic Pain/therapy , Mindfulness/methods , Motivational Interviewing/methods , Neoplasms/psychology , Quality of Life/psychology , Chronic Pain/psychology , Cohort Studies , Female , Humans , Male , Middle Aged
11.
Photoacoustics ; 19: 100181, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32405456

ABSTRACT

Multispectral photoacoustic imaging (MPAI) is a promising emerging diagnostic technology, but fluence artifacts can degrade device performance. Our goal was to develop well-validated phantom-based test methods for evaluating and comparing MPAI fluence correction algorithms, including a heuristic diffusion approximation, Monte Carlo simulations, and an algorithm we developed based on novel application of the diffusion dipole model (DDM). Phantoms simulated a range of breast-mimicking optical properties and contained channels filled with chromophore solutions (ink, hemoglobin, or copper sulfate) or connected to a previously developed blood flow circuit providing tunable oxygen saturation (SO2). The DDM algorithm achieved similar spectral recovery and SO2 measurement accuracy to Monte Carlo-based corrections with lower computational cost, potentially providing an accurate, real-time correction approach. Algorithms were sensitive to optical property uncertainty, but error was minimized by matching phantom albedo. The developed test methods may provide a foundation for standardized assessment of MPAI fluence correction algorithm performance.

12.
Pediatrics ; 144(6)2019 12.
Article in English | MEDLINE | ID: mdl-31685696

ABSTRACT

BACKGROUND: Historically, there has been a shortage of child psychiatrists in the United States, undermining access to care. This study updated trends in the growth and distribution of child psychiatrists over the past decade. METHODS: Data from the Area Health Resource Files were used to compare the number of child psychiatrists per 100 000 children ages 0 to 19 between 2007 and 2016 by state and county. We also examined sociodemographic characteristics associated with the density of child psychiatrists at the county level over this period using negative binomial multivariable models. RESULTS: From 2007 to 2016, the number of child psychiatrists in the United States increased from 6590 to 7991, a 21.3% gain. The number of child psychiatrists per 100 000 children also grew from 8.01 to 9.75, connoting a 21.7% increase. County- and state-level growth varied widely, with 6 states observing a decline in the ratio of child psychiatrists (ID, IN, KS, ND, SC, and SD) and 6 states increasing by >50% (AK, AR, NH, NV, OK, and RI). Seventy percent of counties had no child psychiatrists in both 2007 and 2016. Child psychiatrists were significantly more likely to practice in high-income counties (P < .001), counties with higher levels of postsecondary education (P < .001), and metropolitan counties compared with those adjacent to metropolitan regions (P < .05). CONCLUSIONS: Despite the increased ratio of child psychiatrists per 100 000 children in the United States over the past decade, there remains a dearth of child psychiatrists, particularly in parts of the United States with lower levels of income and education.


Subject(s)
Career Choice , Neurodevelopmental Disorders/epidemiology , Neurodevelopmental Disorders/therapy , Psychiatry/trends , Adolescent , Child , Child, Preschool , Cross-Sectional Studies , Female , Humans , Male , Neurodevelopmental Disorders/psychology , Retrospective Studies , United States/epidemiology
13.
J Biomed Opt ; 24(12): 1-12, 2019 11.
Article in English | MEDLINE | ID: mdl-31705636

ABSTRACT

As photoacoustic imaging (PAI) technology matures, computational modeling will increasingly represent a critical tool for facilitating clinical translation through predictive simulation of real-world performance under a wide range of device and biological conditions. While modeling currently offers a rapid, inexpensive tool for device development and prediction of fundamental image quality metrics (e.g., spatial resolution and contrast ratio), rigorous verification and validation will be required of models used to provide regulatory-grade data that effectively complements and/or replaces in vivo testing. To address methods for establishing model credibility, we developed an integrated computational model of PAI by coupling a previously developed three-dimensional Monte Carlo model of tissue light transport with a two-dimensional (2D) acoustic wave propagation model implemented in the well-known k-Wave toolbox. We then evaluated ability of the model to predict basic image quality metrics by applying standardized verification and validation principles for computational models. The model was verified against published simulation data and validated against phantom experiments using a custom PAI system. Furthermore, we used the model to conduct a parametric study of optical and acoustic design parameters. Results suggest that computationally economical 2D acoustic models can adequately predict spatial resolution, but metrics such as signal-to-noise ratio and penetration depth were difficult to replicate due to challenges in modeling strong clutter observed in experimental images. Parametric studies provided quantitative insight into complex relationships between transducer characteristics and image quality as well as optimal selection of optical beam geometry to ensure adequate image uniformity. Multidomain PAI simulation tools provide high-quality tools to aid device development and prediction of real-world performance, but further work is needed to improve model fidelity, especially in reproducing image noise and clutter.


Subject(s)
Breast Neoplasms/diagnostic imaging , Photoacoustic Techniques/methods , Acoustics , Algorithms , Animals , Computer Simulation , Contrast Media/pharmacology , Female , Humans , Imaging, Three-Dimensional , Monte Carlo Method , Phantoms, Imaging , Reproducibility of Results , Signal-To-Noise Ratio , Sound , Transducers
14.
J Am Acad Child Adolesc Psychiatry ; 58(10): 1016-1019, 2019 10.
Article in English | MEDLINE | ID: mdl-31561829

ABSTRACT

Estimates are that half of children with mental health problems do not receive needed treatment.1 One of the barriers they face is that there are not enough child mental health specialty providers to meet their needs.2 Pediatric providers, who might partially fill this gap, often feel they lack the training to treat children's mental health disorders without consulting a specialist.3.


Subject(s)
Adolescent Health Services/organization & administration , Child Health Services/organization & administration , Mental Disorders/therapy , Patient Acceptance of Health Care/statistics & numerical data , Referral and Consultation , Telephone , Adolescent , Adolescent Health Services/standards , Child , Child Health Services/standards , Child, Preschool , Female , Humans , Male , Program Evaluation , United States
15.
J Biomed Opt ; 24(6): 1-10, 2019 06.
Article in English | MEDLINE | ID: mdl-31230425

ABSTRACT

Plasmonic nanoparticles (PNPs) continue to see increasing use in biophotonics for a variety of applications, including cancer detection and treatment. Several PNP-based approaches involve the generation of highly transient nanobubbles due to pulsed laser-induced vaporization and cavitation. While much effort has been devoted to elucidating the mechanisms behind bubble generation with spherical gold nano particles, the effects of particle shape on bubble generation thresholds are not well understood, especially in the nanosecond pulse regime. Our study aims to compare the bubble generation thresholds of gold nanospheres, gold nanorods, and silica-core gold nanoshells with different sizes, resonances, and surface coatings. Bubble generation is detected using a multimodality microscopy platform for simultaneous, nanosecond resolution pump-probe imaging, integrated scattering response, and acoustic transient detection. Nanoshells and large (40-nm width) nanorods were found to have the lowest thresholds for bubble generation, and in some cases they generated bubbles at radiant exposures below standard laser safety limits for skin exposure. This has important implications for both safety and performance of techniques employing pulsed lasers and PNPs.


Subject(s)
Metal Nanoparticles/radiation effects , Nanostructures/radiation effects , Surface Plasmon Resonance/methods , Acoustics , Gold , Logistic Models , Materials Testing , Nanoshells , Scattering, Radiation
16.
Biomed Opt Express ; 10(4): 1919-1934, 2019 Apr 01.
Article in English | MEDLINE | ID: mdl-31061767

ABSTRACT

Innovative biophotonic modalities such as photoacoustic imaging (PAI) have the potential to provide enhanced sensitivity and molecule-specific detection when used with nanoparticles. However, high peak irradiance levels generated by pulsed lasers can lead to modification of plasmonic nanoparticles. Thus, there is an outstanding need to develop practical methods to effectively predict the onset nanoparticle photomodification as well as a need to better understand the process during PAI. To address this need, we studied pulsed laser damage of gold nanorods (GNRs) using turbid phantoms and a multi-spectral near-infrared PAI system, comparing results with spectrophotometric measurements of non-scattering samples. Transmission electron microscopy and Monte Carlo modeling were also performed to elucidate damage processes. In the phantoms, shifts in PAI-detected spectra indicative of GNR damage were initiated at exposure levels one-third of that seen in non-scattering samples, due to turbidity-induced enhancement of subsurface fluence. For exposures approaching established safety limits, damage was detected at depths of up to 12.5 mm. Typically, GNR damage occurred rapidly, over the course of a few laser pulses. This work advances the development of test methods and numerical models as tools for assessment of nanoparticle damage and its implications, and highlights the importance of considering GNR damage in development of PAI products, even for exposures well below laser safety limits.

17.
Biomed Opt Express ; 10(2): 449-464, 2019 Feb 01.
Article in English | MEDLINE | ID: mdl-30800492

ABSTRACT

Multispectral photoacoustic oximetry imaging (MPOI) is an emerging hybrid modality that enables the spatial mapping of blood oxygen saturation (SO2) to depths of several centimeters. To facilitate MPOI device development and clinical translation, well-validated performance test methods and improved quantitative understanding of physical processes and best practices are needed. We developed a breast-mimicking blood flow phantom with tunable SO2 and used this phantom to evaluate a custom MPOI system. Results provide quantitative evaluation of the impact of phantom medium properties (Intralipid versus polyvinyl chloride plastisol) and device design parameters (different transducers) on SO2 measurement accuracy, especially depth-dependent performance degradation due to fluence artifacts. This approach may guide development of standardized test methods for evaluating MPOI devices.

18.
Sci Rep ; 8(1): 6360, 2018 Apr 18.
Article in English | MEDLINE | ID: mdl-29670224

ABSTRACT

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has been fixed in the paper.

19.
Rehabil Psychol ; 63(1): 16-28, 2018 02.
Article in English | MEDLINE | ID: mdl-29553780

ABSTRACT

OBJECTIVE: The objective of the study was to review the evidence for the effectiveness of telephone psychotherapy on psychological outcomes in people with multiple sclerosis (MS). METHOD: We conducted a systematic search of EMBASE, PsycINFO, PsycARTICLES, MEDLINE, CINAHL, Web of Science, and hand-searched relevant journals to identify randomized controlled trials (RCTs) that evaluated the effectiveness of telephone psychotherapy on psychological outcomes in people with MS (last search completed on October 1, 2015). The methodological quality of each included trial was assessed, based on a standardized list of methodological criteria. Where available, data were extracted and combined in a meta-analysis to compute effect size estimates. RESULTS: Eleven RCTs and 1,104 participants were identified. The meta-analysis found a moderate effect of the intervention on depression (SMD 0.47 [95% confidence interval 0.21-0.73]). The meta-analysis also found small to moderate short-term effects of the intervention on fatigue, quality of life, MS symptoms, physical activity, and medication adherence, compared with controls and other interventions. RCT designs were heterogeneous. All studies had at least 1 high or unclear risk of bias. CONCLUSIONS: Telephone psychotherapy provides small and moderate benefits in depression, fatigue, quality of life, MS symptoms, physical activity, and medication adherence in the short term. Few gains were sustained in the long term. Studies of better quality are needed. (PsycINFO Database Record


Subject(s)
Multiple Sclerosis/psychology , Multiple Sclerosis/rehabilitation , Psychotherapy/methods , Telemedicine/methods , Telephone , Humans , Treatment Outcome
20.
Sci Rep ; 7(1): 15704, 2017 Nov 16.
Article in English | MEDLINE | ID: mdl-29146935

ABSTRACT

The rapid growth of gold nanoparticle applications in laser therapeutics and diagnostics has brought about the need for establishing innovative standardized test methods for evaluation of safety and performance of these technologies and related medical products. Furthermore, given the incomplete and inconsistent data on nanoparticle photomodification thresholds provided in the literature, further elucidation of processes that impact the safety and effectiveness of laser-nanoparticle combination products is warranted. Therefore, we present a proof-of-concept study on an analytical experimental test methodology including three approaches (transmission electron microscopy, dynamic light scattering, and spectrophotometry) for experimental evaluation of damage thresholds in nanosecond pulsed laser-irradiated gold nanospheres, and compared our results with a theoretical model and prior studies. This thorough evaluation of damage threshold was performed based on irradiation with a 532 nm nanosecond-pulsed laser over a range of nanoparticle diameters from 20 to 100 nm. Experimentally determined damage thresholds were compared to a theoretical heat transfer model of pulsed laser-irradiated nanoparticles and found to be in reasonably good agreement, although some significant discrepancies with prior experimental studies were found. This study and resultant dataset represent an important foundation for developing a standardized test methodology for determination of laser-induced nanoparticle damage thresholds.

SELECTION OF CITATIONS
SEARCH DETAIL
...