Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Article in German | MEDLINE | ID: mdl-35172341

ABSTRACT

Postoperative deaths are a consequence of postoperative complications - including acute kidney injury and myocardial injury. Postoperative complications are associated with non-modifiable patient-specific risk factors (i.e., age, medical history), but also with potentially modifiable risk factors - including intraoperative hypotension and compromised intraoperative blood flow. Based on patient- and surgery-specific risk factors, the intraoperative hemodynamic monitoring strategy needs to be selected. Intraoperative hypotension is associated with postoperative organ failure and should thus be avoided. To optimize intraoperative hemodynamics, cardiac output-guided hemodynamic management has been proposed. Cardiac output-guided hemodynamic management aims at optimizing oxygen delivery using fluids, vasopressors, and inotropes. Cardiac output-guided hemodynamic management has been shown to reduce postoperative complications compared to routine hemodynamic management in high-risk patients having major surgery.


Subject(s)
Hemodynamic Monitoring , Hypotension , Cardiac Output , Hemodynamic Monitoring/adverse effects , Hemodynamics , Humans , Hypotension/diagnosis , Hypotension/etiology , Hypotension/prevention & control , Intraoperative Complications/diagnosis , Intraoperative Complications/prevention & control , Monitoring, Intraoperative , Postoperative Complications/diagnosis , Postoperative Complications/prevention & control
2.
Crit Care ; 25(1): 125, 2021 03 29.
Article in English | MEDLINE | ID: mdl-33781307

ABSTRACT

BACKGROUND: Pulmonary artery thermodilution is the clinical reference method for cardiac output monitoring. Because both continuous and intermittent pulmonary artery thermodilution are used in clinical practice it is important to know whether cardiac output measurements by the two methods are clinically interchangeable. METHODS: We performed a systematic review and meta-analysis of clinical studies comparing cardiac output measurements assessed using continuous and intermittent pulmonary artery thermodilution in adult surgical and critically ill patients. 54 studies with 1522 patients were included in the analysis. RESULTS: The heterogeneity across the studies was high. The overall random effects model-derived pooled estimate of the mean of the differences was 0.08 (95%-confidence interval 0.01 to 0.16) L/min with pooled 95%-limits of agreement of - 1.68 to 1.85 L/min and a pooled percentage error of 29.7 (95%-confidence interval 20.5 to 38.9)%. CONCLUSION: The heterogeneity across clinical studies comparing continuous and intermittent pulmonary artery thermodilution in adult surgical and critically ill patients is high. The overall trueness/accuracy of continuous pulmonary artery thermodilution in comparison with intermittent pulmonary artery thermodilution is good (indicated by a pooled mean of the differences < 0.1 L/min). Pooled 95%-limits of agreement of - 1.68 to 1.85 L/min and a pooled percentage error of 29.7% suggest that continuous pulmonary artery thermodilution barely passes interchangeability criteria with intermittent pulmonary artery thermodilution. PROSPERO registration number CRD42020159730.


Subject(s)
Cardiac Output/physiology , Pulmonary Artery/physiopathology , Thermodilution/instrumentation , Weights and Measures/instrumentation , Humans , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Reproducibility of Results , Thermodilution/methods , Weights and Measures/standards
3.
Eur J Anaesthesiol ; 38(6): 616-624, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33653983

ABSTRACT

BACKGROUND: The effect of different methods for data sampling and data processing on the results of comparative statistical analyses in method comparison studies of continuous arterial blood pressure (AP) monitoring systems remains unknown. OBJECTIVE: We sought to investigate the effect of different methods for data sampling and data processing on the results of statistical analyses in method comparison studies of continuous AP monitoring systems. DESIGN: Prospective observational study. SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany, from April to October 2019. PATIENTS: 49 patients scheduled for neurosurgery with AP measurement using a radial artery catheter. MAIN OUTCOME MEASURES: We assessed the agreement between continuous noninvasive finger cuff-derived (CNAP Monitor 500; CNSystems Medizintechnik, Graz, Austria) and invasive AP measurements in a prospective method comparison study in patients having neurosurgery using all beat-to-beat AP measurements (Methodall), 10-s averages (Methodavg), one 30-min period of 10-s averages (Method30), Method30 with additional offset subtraction (Method30off), and 10 30-s periods without (Methodiso) or with (Methodiso-zero) application of the zero zone. The agreement was analysed using Bland-Altman and error grid analysis. RESULTS: For mean AP, the mean of the differences (95% limits of agreement) was 9.0 (-12.9 to 30.9) mmHg for Methodall, 9.2 (-12.5 to 30.9) mmHg for Methodavg, 6.5 (-9.3 to 22.2) mmHg for Method30, 0.5 (-9.5 to 10.5) mmHg for Method30off, 4.9 (-6.0 to 15.7) mmHg for Methodiso, and 3.4 (-5.9 to 12.7) mmHg for Methodiso-zero. Similar trends were found for systolic and diastolic AP. Results of error grid analysis were also influenced by using different methods for data sampling and data processing. CONCLUSION: Data sampling and data processing substantially impact the results of comparative statistics in method comparison studies of continuous AP monitoring systems. Depending on the method used for data sampling and data processing, the performance of an AP test method may be considered clinically acceptable or unacceptable.


Subject(s)
Arterial Pressure , Blood Pressure Determination , Austria , Blood Pressure , Germany , Humans , Prospective Studies
4.
J Clin Monit Comput ; 35(4): 827-834, 2021 08.
Article in English | MEDLINE | ID: mdl-32504156

ABSTRACT

Peroral endoscopic myotomy (POEM) is natural orifice transluminal endoscopic surgery to treat esophageal achalasia. During POEM, cardiovascular dynamics can be impaired by capnoperitoneum, capnomediastinum, and systemic carbon dioxide accumulation. We systematically investigated changes in cardiovascular dynamics during POEM. We included 31 patients having POEM in this single-center prospective observational study. Before and every 5 min during POEM we measured mean arterial pressure (MAP), heart rate (HR), cardiac index (CI), stroke volume index (SVI), and systemic vascular resistance index (SVRI) using non-invasive finger cuff-derived pulse wave analysis. During POEM, the median MAP was higher than the median baseline MAP of 77 (67;86) mmHg. HR (median at baseline: 67 (60;72) bpm), CI (2.8 (2.5;3.2) L/min/m2), SVI (42 (34;51) mL/m2), and SVRI (1994 (1652; 2559) dyn × s × cm-5 × m-2) remained stable during POEM. Mixed model-derived 95% confidence limits of hemodynamic variables during POEM were 72 to 106 mmHg for MAP, 65 to 79 bpm for HR, 2.7 to 3.3 L/min/m2 for CI, 37 and 46 mL/m2 for SVI, and 1856 and 2954 dyn × s × cm-5 × m-2 for SVRI. POEM is a safe procedure with regard to cardiovascular dynamics as it does not markedly impair MAP, HR, CI, SVI, or SVRI.


Subject(s)
Esophageal Achalasia , Myotomy , Natural Orifice Endoscopic Surgery , Esophageal Achalasia/surgery , Humans , Pulse Wave Analysis , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...